The Martindale TL326-EV simplifies the connection of test equipment to EVSE charging points with a Type-2 connector. It is suitable for single- and three-phase applications and provides access to L1, L2, L3, N, CP, and PE connections.
The CP mode slider switch allows users to simulate vehicle states, including an “E” (error) mode to replicate CP signal failures. The LED indicators display the status of the CP and phase connections. It is compatible with EV-ready Multifunction Testers (MFTs) via standard 4mm jack plugs and supports all relevant measurements through standard inputs.
ELECTRICAL | |
---|---|
Nominal Operating Voltage | 230V ~ / 400V 3 ~ |
Operating Frequency | 10HZ - 499HZ |
GENERAL | |
Dimensions | approx. Plug 230 x 60 x 55mm |
Weight | 300g |
Mains Socket and Lead Rating | max. 10A |
PP Simulation | Setup internally to 20 A |
CP Simulation | States A, B, C |
Error Simulation | CP error “E” |
Test Connector Type | IEC 62196-2 Type 2 male |
ENVIRONMENTAL | |
Location | Suitable for indoor and outdoor use in dry weather conditions only |
Altitude | up to 2000m |
Operating Temperature Range | 0°C to 40°C |
Storage Temperature | -0°C to 50°C |
Relative Humidity Range | 0 - 80%RH |
Mains Supply Voltage Fluctuations | ±10% |
Overvoltage Category | CAT II 300V |
Pollution Degree | 2 |
SAFETY | |
Conforms to | BS EN 61010-1, BS EN 61010-031 |
Rating | Class II, Reinforced insulation |