This special bundle version of the Martindale HPAT600/2 includes essential PAT accessories which will be used commonly when out testing.
Battery-powered and suitable for use with all types of appliance, the HPAT600 is ideal for quick PAT testing checks. The HPAT600 includes two modes: automatic and manual. In automatic mode, the tester will run through a selected sequence without any interaction, helping to speed up testing. The manual mode can be used for further control over a test and includes a connection diagram and steps must be configured by the user before they are activated.
This tester is fully suitable for use on both 240V and 110V appliances, class I and class II appliances, power leads and includes a special 200mA DC earth bond test function for safely testing IT equipment.
Alongside the HPAT600/2 PAT Tester, this kit also includes:
Earth Continuity | |
Test Voltage | 4V DC (into open circuit) |
Test Current | 200mA DC (into short circuit) |
Range | 0 to 19.99Ω |
Resolution | 0.01Ω |
Accuracy | ± (5% of reading + 2 digits) |
Fixed Pass Limits | |
Lead | ≤ 0.10 Ω = PASS > 0.10Ω ≤ 0.20Ω = NOTE x.xx PASS* |
Class I | Class I ≤ 0.10 Ω = PASS > 0.10Ω ≤ 0.20Ω = NOTE x.xx PASS* |
Note | *Allows user defined pass values to be recorded, eg. for long cord lengths. |
User settable limits | ≤0.1Ω to ≤0.9Ω in 0.1Ω steps |
Insulation | |
Test Voltage | User selectable > 250V DC at 1mA / > 500V DC at 1mA (< 312.5V DC open circuit / < 625V DC open circuit) |
Test Current | Test current: 1.5mA (into short circuit) |
Ranges | 2.00MΩ, 20.0MΩ, 200MΩ |
Resolution | 0.01MΩ |
Accuracy | <100MΩ ± (5% reading + 2 digits) >100MΩ ± (10% reading + 2 digits) |
Fixed Pass Levels | Lead: ≥ 1.0 MΩ Class I: ≥ 1.0 MΩ Class II: ≥ 2.0 MΩ |
Pass level | Lead: ≥ 1.0MΩ, Class I: ≥ 1.0MΩ, Class II: ≥ 2.0MΩ |
User Settable PASS level | ≥ 0.3MΩ to ≥ 1MΩ in 0.1MΩ steps ≥ 1MΩ to ≥ 10MΩ in 1MΩ steps |
Fuse Checks | |
Test Voltage | 4V DC (into open circuit) |
Test Current | 200mA DC (into short circuit) |
Pass Level | >2mA |
Simulatted Load Test | |
Test voltage | 4V DC (into open circuit) |
Test current | 200mA DC (into short circuit) |
Accuracy | ± (5% reading + 2 digits) |
Threshold for ‘Simulated Current Hi’ | 16A |
Memory | 200 tests stored for on-screen recall |
General | |
Overload Protection | 300V AC/DC |
Protection class | IP20 |
Safety | Complies to BS EN 61010-1 |
Temperature Range | -10 to 40°C, non-condensing |
Batteries | 6 x 1.2V AA NiMH rechargeable batteries 1800mAh, or greater |
Battery Life | Fully charged, minimum 600 complete tests. The HPAT500 will operate fully from the battery charger in the event of discharged batteries. Do not remove batteries. |
Auto Shut Down | After 10 minutes of inactivity, or when battery low |
Battery Charger Input | 230V 50Hz |
Battery Charger Output | 12VDC at 300mA, 5.5 jack x 2.5 bore centre positive |
Dimensions | 90 x 210 x 54mm |
Weight | Approx 700g (including batteries & leads) |