The Martindale HPAT400 Pass/Fail PAT Tester is a simple, non-downloadable PAT tester. It is IT-safe and can be used to test a variety of electrical appliances. It features a one-touch operating system, allowing the user to select the relevant automatic test sequence by pressing the corresponding button. The tester can be set to perform automatic, full test sequences for Class I or Class II appliances or power leads. This instrument also includes an IT-safe 200mA earth bond test.
To extend the HPAT400’s testing capabilities even further, it is equipped with an integrated three-phase plug and is supplied with an extension lead adapter, and earth bond probe with clip. This PAT tester can also be used with a range of OPTIONAL adapters for testing 110V appliances.
The PAT Tester will show test results on its backlit display; results are communicated using a simple and clear PASS or FAIL indication. Please note that this model will not display values.
The small, lightweight design makes it suitable for testing in a variety of locations, for instance beneath desks or at wall-mounted monitors. Other practical features include connection diagrams printed on the body of the instrument, which are designed to aid the user with conducting tests correctly. It is also supplied with a practical Test & Go Carry Case with a separate pocket for accessories.
The Martindale HPAT400 Pass/Fail PAT Tester is a small, simple-to-use, non-downloadable PAT tester suitable for performing quick and complete tests of an array of electrical equipment.
HPAT400 | HPAT500/2 | HPAT600/2 | |
---|---|---|---|
Class I/II Test | Yes | ||
Lead Test | Yes | ||
Pass/Fail Indication | Yes | ||
Test Values Displayed | No | Yes | |
Selectable Limits | No | Yes | |
Test Mode | Auto | Auto/Manual | |
Run Test | No | Simulated | |
Earth Continuity Test Current | 200mA | ||
Insulation Test Voltage | 250/500V | ||
110V Appliances | With additional accessory | ||
Memory | No | 200 results | |
Power | Alkaline batteries | Rechargeable batteries |
Enjoy peace of mind with a Free PAT Card included with every purchase. Keep track of essential safety checks effortlessly!
Earth Continuity | |
Test voltage | 4V DC (into open circuit) |
Test current | 200mA DC (into short circuit) |
Accuracy | ± 0.03Ω |
Pass Limits | Lead ≤ 0.20 Ω = PASS |
Class I ≤ 0.20 Ω = PASS | |
Insulation | |
Fixed voltage | >500V DC at 1mA (< 625V DC into open circuit) |
Test current | 1.5mA (into short circuit) |
Accuracy | ± 0.1MΩ |
Pass limits | Lead: ≥ 1.0 MΩ |
Class I: ≥ 1.0 MΩ | |
Class II: ≥ 2.0 MΩ | |
Fuse Check | |
Test voltage | 4V DC (into open circuit) |
Test current | 200mA DC (into short circuit) |
Pass level | >2mA |
General | |
Overload protection | 300V AC/DC |
Protection class | IP20 |
Safety | Complies to BS EN 61010-1 |
Temperature Range | -10 to 40°C, non-condensing |
Batteries | 6 x AA alkaline batteries |
Battery Life | minimum 600 complete tests |
Auto Power Down | After 10 minutes of inactivity, or when battery low |
Dimensions | 90 x 210 x 54mm |
Weight | Approx 700g (including batteries & leads) |