All Martindale Products

Martindale CM84 AC/DC Clamp Meter

SKU
MARCM84
Rating:
0%
(0)
Reward Points
:
158
£190.20 £158.50
Only 1 in Stock
Advice & Support Call 01642 931329 or contact us
Price Match We won't be beaten, let us know
Martindale CM84 AC/DC Clamp Meter - Kit

Test more with the CM84, the upgraded version of Martindale's CM82 clamp meter!

The main difference between the two testers is that the CM84 is both an AC and DC clamp, whereas the CM82 is only AC. It can test AC current from 400A to 1000A and also tests DC current across the same range, with both measurements carried out with high levels of accuracy.

It doesn't stop there either; the CM84 has a built-in multimeter so it can calculate DC voltage to 1000V, AC voltage to 750V, resistance to 40MΩ, frequency to 1MHz and continuity/diode testing.

The CM84 has 57mm jaws and is CAT IV 600V and CAT III 1000V rated.

Martindale CM84 AC/DC Clamp Meter Key Features

  • Measurements of AC and DC current to 1000A
  • DC voltage measurements to 1000V
  • AC voltage measurements to 750V
  • Resistance measurements to 40MΩ
  • Frequency measurements to 1MHz
  • Continuity/diode test
  • 57mm jaws

What's Included?

  • Martindale CM84 AC/DC Clamp Meter
  • Carrying Case
  • TL16 Test Leads
  • 9V PP3 Battery (Installed)
  • Instructions

Martindale CM82 Technical Specifications

All specified accuracies are at 23°C ± 5°C, <70% RH for 1 year
Temperature Coefficient: 0.1 x (specified accuracy) per °C (0°C to 18°C, 28°C to 50°C)
All accuracies below are expressed as ± (percentage of reading + digits)

DC Voltage   
Range Resolution Input Impedance Accuracy
400mV 0.1mV >100MΩ 0.5% + 2
4V 0.001V 10MΩ
40V 0.01V 9.1MΩ
400V 0.1V
1000V 1V
AC Voltage   
Range Resolution Input Impedance Accuracy (50Hz to 500Hz)
400mV 0.1mV >100MΩ Not specified
4V 0.001V 10MΩ 1.5% + 5
40V 0.01V 9.1MΩ
400V 0.1V
750V 1V
AC Current   
Range Resolution Accuracy
50Hz to 60Hz/60 to 400Hz
40A 0.01A 2.0% + 6
3.0% + 6
400A 0.1
1000A 1A 2.0% + 6 (≤600A)
2.5% + 6 (>600A)
3.0% + 6 (≤600A)
3.5% + 6 (>600A)
 
DC Current   
Range Resolution Accuracy
400A 0.1A 2.0% + 5  
1000A 1A 2.0% + 5 (≤600A)
3.0% + 5 (>600A)
Resistance  
Range Resolution Open Circuit Voltage Accuracy
400Ω 0.1Ω -1.2V DC 1.0% + 5
4kΩ 0.001kΩ -0.45V DC
40kΩ 0.01kΩ
400kΩ 0.1kΩ
4MΩ 0.001MΩ 2.0% + 5
40MΩ 0.01MΩ 3.5% + 5
Capacitance  
Range Resolution Accuracy
4nF 0.001nF Not specified
40nF 0.01nF
400nF 0.1nF
4μF 0.001μF 3.0% + 15
40μF 0.01μF 3.0% + 10
400μF 0.1μF
4mF 0.001mF 5.0% + 10
Frequency  
Range Resolution Accuracy
4kHz 0.001kHz 0.1% + 3
40kHz 0.01kHz
400kHz 0.1kHz
1MHz 0.001MHz

(further tech specs in attached datasheet/manual)

Accessories related to this product:
Martindale CM84 Clamp Meter - Datasheet Datasheets Martindale CM84 Clamp Meter - User Manual Manuals & Guides

Reviews

Additional Information
SKU MARCM84
Manufacturer Part Code MARCM84