The Kid-Safe Anti-Fog PPE Children's Face Visor/ Shield offers full-face protection against liquid droplets, sprays and splashes. It is designed to be worn by children aged four years and older.
The Kid-Safe Anti-Fog PPE Children's Face Visor/ Shield is lightweight and comprised of two parts: an adjustable, comfortable headband and an anti-fog visor printed with a brightly coloured rainbow. The Kid-Safe Anti-Fog PPE Children's Face Visor/ Shield is easy to assemble and can be altered to accommodate various head sizes, prescription glasses and face masks.
The Kid-Safe Anti-Fog PPE Children's Face Visor/ Shield is made from optical-grade, clear, recyclable 300micron P.E.T. It has the following dimensions, 272mm x 210mm (WxL), ensuring that it will cover the child’s mouth, nose and eyes.
This lightweight, low-cost Kid-Safe Anti-Fog PPE Children's Face Visor/ Shield is ideal for protecting children against the transmission of infection in busy areas such as schools, hospitals and public transport.
Kid-Safe Anti-Fog PPE Children's Face Visor/ Shield Key Features
- Provides full-face protection against liquid droplets, sprays and splashes
- For children aged 4+
- Lightweight
- Comprised of two easy-to-assemble parts: a headband and visor
- The comfortable, adjustable headband can be altered to accommodate a range of head sizes
- The anti-fog visor is printed with a brightly coloured rainbow
- Can be worn with prescription glasses and face masks
- Made from optical-grade, clear, recyclable 300micron P.E.T
- Dimensions (WxL): 272mm x 210mm
- Covers the child’s eyes, mouth and nose
- Low cost
- Protect children against the transmission of infection in busy areas such as schools, hospitals and public transport
What’s Included?
- Kid-Safe Anti-Fog PPE Children's Face Visor/ Shield
Sonel PVM-1530 Photovoltaic Meter
Parameter | Measurement Range | Display Range | Resolution | Accuracy |
---|---|---|---|---|
Voltage | ||||
AC voltage | 0.0 V…1000.0 V | 0.0 V…1000.0 V | 0.1 V | ±(2% m.v. + 6 digits) |
DC voltage | 0.0 V…1500.0 V | 0.0 V…1500.0 V | 0.1 V | ±(0.5% m.v. + 2 digits) |
Frequency | 10.0 Hz…100.0 Hz | 0 Hz…100.0 Hz | 0.1 Hz | ±(0.5% m.v. + 2 digits) |
Short Circuit Current ISC | ||||
Voltage 1500 V DC | 0.00…30.00 A | 0.00…30.00 A | 0.01 A | ±(1% m.v. + 2 digits) |
Voltage 1000 V DC | 0.00…40.00 A | 0.00…40.00 A | 0.01 A | ±(1% m.v. + 2 digits) |
Insulation Resistance | ||||
Insulation resistance at the AC side | ||||
• Measuring voltage 250 V | 250 kΩ…200 MΩ acc. to IEC 61557-2 |
0.0 kΩ…200.0 MΩ | from 0.1 kΩ | ±(3% m.v. + 8 digits) |
• Measuring voltage 500 V | 500 kΩ…500 MΩ acc. to IEC 61557-2 |
0.0 kΩ…500.0 GΩ | from 0.1 kΩ | ±(3% m.v. + 8 digits) |
• Measuring voltage 1000 V | 1000 kΩ…1.000 GΩ acc. to IEC 61557-2 |
0.0 kΩ…1.000 GΩ | from 0.1 kΩ | ±(3% m.v. + 8 digits) |
Insulation resistance at the DC side | ||||
• Measuring voltage 250 V / 500 V / 1000 V / 1500 V | 250 kΩ…500 GΩ acc. to IEC 61557-2 |
0.0 kΩ…500.0 GΩ | from 0.1 kΩ | ±(8% m.v. + 8 digits) |
Resistance of Protective Conductors and Equipotential Bondings | ||||
Measurement of resistance of protective conductors and equipotential bondings with ±200 mA current | 0.10 Ω…1999 Ω acc. to IEC 61557-4 |
0.00 Ω…1999 Ω | from 0.01 Ω | from ±(2% m.v. + 3 digits) |
Operating Current | as for CMP-1015-PV | as for CMP-1015-PV | as for CMP-1015-PV | as for CMP-1015-PV |
Power Measurement | 0.0 kW…999.0 kW | 0.0 kW…999.0 kW | 0.1 kW | ±(6% m.v. + 5 digits) |
Sonel IRM-1 Solar Radiation & Temperature Meter
Parameter | Measurement Range | Display Range | Resolution | Accuracy |
---|---|---|---|---|
Irradiance | ||||
Measurement in W/m2 | 100 W/m2 …1400 W/m2 | 0 W/m2 …1400 W/m2 | 1 W/m2 | ±(5% m.v. + 2 digits) |
Measurement in BTU/ft2 h | 32 BTU/ft2h…444 BTU/ft2h | 0 BTU/ft2h…444 BTU/ft2h | 1 BTU/ft2h | ±(5% m.v. + 2 digits) |
PV and Ambient Temperature | ||||
Measurement in °C | -20.0°C…100.0°C | -20.0°C…100.0°C | 0.1°C | ±(1% m.v. + 5 digits) |
Measurement in °F | -4.0°F…212.0°F | 4.0°F…212.0°F | 0.1°F | ±(1% m.v. + 5 digits) |
Inclination Angle | -90°…+90° | -90°…+90° | 1° | ±2° |
Position Direction - Compass | 0°…360° | 0°…360° | 1° | ±5° |
Sonel CMP-1015-PV Digital Clamp Meter
Measurement Functions | Range | Resolution | Accuracy |
---|---|---|---|
AC Current | up to 1000 A | from 0.01 A | ±(2.5% m.v. + 5 digits) |
DC Current | up to 1000 A | from 0.01 A | ±(2.0% m.v. + 8 digits) |
AC Voltage | up to 1000 V | from 0.001 mV | from ±(1.2% m.v. + 5 digits) |
DC Voltage | up to 1500 V | from 0.1 mV | from ±(0.5% m.v. + 5 digits) |
AC+DC Voltage | up to 1000 V | from 0.001 V | from ±(1.5% m.v. + 20 digits) |
Low Z (AC / DC Voltage) | up to 1000 V | from 0.001 V | ±(3.0% m.v. + 40 digits) |
Low Z AC+DC | up to 1000 V | from 0.001 V | ±(3.5% m.v. + 40 digits) |
Resistance | up to 60.00 MΩ | from 0.1 Ω | from ±(0.8% m.v. + 5 digits) |
Frequency | up to 10.00 MHz | from 0.01 Hz | ±(0.2% m.v. + 5 digits) |
Capacitance | up to 100.0 mF | from 0.01 nF | from ±(3.0% m.v. + 8 digits) |
Duty Cycle (%) | 10.0…90.0% | 0.1% | ±(1.2% m.v. + 8 digits) |
Temperature Measurement | -40.0…+1000ºC -40.0…+1832ºF |
0.1ºC 0.1ºF |
±(1.5% m.v. + 3ºC) ±(1.0% m.v. + 5.4ºF) |
Continuity / Diode test | ✓ / ✓ |
Reviews
SKU | TS-FV-K |
---|---|
Manufacturer Part Code | TS-FV-K |