Kewtech’s L8 Legionella Test Kit is a useful temperature measuring kit for monitoring the temperature of water systems to ensure the conditions required for Legionella bacteria growth do not exist. To this end, it includes:
- Kewtech KEW301 Dual Channel Thermometer
- Kewtech REGV30 Surface Probe with K-Type Connector
- Kewtech REGV25 Liquid Probe with K-Type Connector
- Two Additional K-Type Thermocouples
Kewtech KEW301 Dual Channel Thermometer Overview
Capable of measuring temperatures between -200°C to +1370°C to a resolution of 0.1°C, the Kewtech KEW301 Dual Channel Thermometer is a digital thermometer compliant with IEC801-2 and IEC584 standards. It features dual input channels, a dual reading display, and is supplied with two thermocouples. In addition to this, the Kewtech KEW301 Dual Channel Thermometer includes handy functions such as Relative, Min, Max, Average, and Auto Power Off.
Please click here for more information about the Kewtech KEW301 Dual Channel Thermometer.
What’s Included?
- Kewtech KEW301 Dual Channel Thermometer
- Kewtech REGV30 Surface Probe with K-Type Connector
- Kewtech REGV25 Liquid Probe with K-Type Connector
- Two Additional K-Type Thermocouples
Kewtech KEW301 Technical Specifications
Numerical Display | 4 digit liquid crystal display (LCD) |
Measurement Range | -200 to 1370°C (-328 to 2498°F) |
Resolution | -200 to 200°C: 0.1°C 800 to 1370°C: 1°C -200 to 200°F: 0.1°F else 1°F |
Maximum Voltage at Thermocouple Input | 60V DC or 24V RMS AC |
Power Requirements | 9V battery, NEDA 1604 or JIS 006P or IEC6F22 |
Battery Life | Approx 100 hours with alkaline battery |
Sample Rate | 0.6 times per second |
Dimensions | 184 x 64 x 30mm |
Weight | 210g (approx) |
Environmental | |
Operating Temperature | 0 to 50°C (32 to 122°F) |
Operating Humidity | 0 to 80% RH |
Storage Temperature | -10 to 60°C |
Storage Humidity | 0 to 80% RH |
Altitude | Up to 2000m |
Accuracy: At (23 ± 5°C) | |
-200 to 200°C | ±(0.3% reading + 1°C) |
200 to 400°C | ±(0.5% reading + 1°C) |
400 to 1370°C | ±(0.3% reading + 1°C) |
-328 to 400°F | ±(0.5% reading + 2°F) |
-200 to 200°F | ±(0.3% reading + 2°F) |
200 to 400°F | ±(0.5% reading + 2°F) |
400 to 2498°F | ±(0.3% reading + 2°F) |
T1-T2 Measurements | ±(0.5% T1-T2 reading + 2°C) or (0.5% T1-T2 reading +2°F) |