Measure the temperature of two points simultaneously with this thermocouple thermometer from Kewtech.
Designed for use with industry-standard type K thermocouples (two included), the KEW301 can measure temperature from a single input (choice of T1 or T2) or from both simultaneously (T1-T2) for checking differential temperature levels.
This thermometer can measure temperature levels from -200 to 1370°C (-328 to 2498°F) with resolution as low as 0.1°C/°F. The thermometer includes a dual display backlit LCD screen which shows either single or dual testing results and has a tripod connector on the rear for hands-free use.
This meter includes MAX/MIN and AVG modes + a relative function.
Kewtech KEW301 Dual Channel Thermometer Key Features
- Dual channels - accepts two type K thermocouples
- Dual display - shows either a single measurement or T1-T2 measurements
- PC interface
- Automatic power off when left idle
- Backlit LCD screen
- MAX/MIN/AVG modes
- Relative function
- Tripod connector
What's Included?
- Kewtech KEW301 Dual Channel Thermometer
- 2 x K-Type Bead Probes
- Battery
- Carrying Case
- Instruction Manual
Kewtech KEW301 Technical Specifications
Numerical Display | 4 digit liquid crystal display (LCD) |
Measurement Range | -200 to 1370°C (-328 to 2498°F) |
Resolution | -200 to 200°C: 0.1°C 800 to 1370°C: 1°C -200 to 200°F: 0.1°F else 1°F |
Maximum Voltage at Thermocouple Input | 60V DC or 24V RMS AC |
Power Requirements | 9V battery, NEDA 1604 or JIS 006P or IEC6F22 |
Battery Life | Approx 100 hours with alkaline battery |
Sample Rate | 0.6 times per second |
Dimensions | 184 x 64 x 30mm |
Weight | 210g (approx) |
Environmental | |
Operating Temperature | 0 to 50°C (32 to 122°F) |
Operating Humidity | 0 to 80% RH |
Storage Temperature | -10 to 60°C |
Storage Humidity | 0 to 80% RH |
Altitude | Up to 2000m |
Accuracy: At (23 ± 5°C) | |
-200 to 200°C | ±(0.3% reading + 1°C) |
200 to 400°C | ±(0.5% reading + 1°C) |
400 to 1370°C | ±(0.3% reading + 1°C) |
-328 to 400°F | ±(0.5% reading + 2°F) |
-200 to 200°F | ±(0.3% reading + 2°F) |
200 to 400°F | ±(0.5% reading + 2°F) |
400 to 2498°F | ±(0.3% reading + 2°F) |
T1-T2 Measurements | ±(0.5% T1-T2 reading + 2°C) or (0.5% T1-T2 reading +2°F) |
Temperature Coefficient | For ambient temperatures from 0 to 18°C and 28 to 50°C, for each °C ambient below 18°C or above 28°C add the following tolerance into the accuracy spec: 0.01% of reading + 0.03°C (0.01% of reading + 0.06°F) |
Reviews
SKU | KEW301 |
---|---|
Manufacturer Part Code | KEW301 |
Model Ref | KEW301 Thermometer |