FREE - PASS The Complete Guide to EET (PAT) Testing, 5th Edition
Buy a PAT testing kit and get an updated PAT Testing Guide worth £24.99. This 129 page indepth PAT testing book is a great addition to your kit. View PAT Guide
Kewtech EZYPAT PAT Tester - Kit 2
The Kewtech EZYPAT PAT Tester – PAT Professional Kit (Bundle 2) consists of the Kewtech EZYPAT PAT Tester (supplied with standard manufacturer’s accessories) and an array of additional PAT testing accessories, such as fuses, labels, logbook and the SimplyPats Manual PAT Testing Software. For a comprehensive overview of the items included in this bundle, please see the ‘What’s Included?’ section.
The Kewtech EZYPAT PAT Tester has the following testing capabilities:
- 200mA continuity
- 1-second quick check continuity test
- 5-second continuity test
- 250V DC insulation test
- 500V DC insulation test
- Substitute leakage test
- Polarity check
- Extension lead test
It is suitable for performing manual dead tests on extension leads, as well as Class I and Class II appliances without electronic on/off switches. To this end it includes pre-programmed automatic test sequences for extension leads and Class I and Class II appliances which can be run via pressing clearly labelled function buttons.
Other functions present on this entry-level model include a Test Lead Null setting, which eliminates test lead resistance thereby ensuring that tests are conducted accurately, and an Appliance Pre-Check feature. The latter feature allows the user to ascertain whether the appliance-under-investigation is powered on or off prior to commencing any tests, protecting both the user and the instrument from damage.
Further to this, the inclusion of a low current continuity test and 250V insulation test ensures that the Kewtech EZYPAT PAT Tester is IT safe, expanding its scope-for-use.
The Kewtech EZYPAT PAT Tester is battery powered and can perform approximately 1400 tests over the course of a battery life cycle. Results of these tests are indicated on the tester’s large, backlit display. The Kewtech EZYPAT PAT Tester’s backlight will change to green when a test has been passed and will change to red if it has been failed. This colour change along with a written PASS or FAIL indication, and a numerical value, add to the ease-of-use of this tester.
Furthermore, it can be easily adapted using the supplied Kewtech accessories to suit the test environments and/or to facilitate the operator’s testing requirements. The Kewtech EZYPAT PAT Tester is supplied with an extension lead adapter and an earth continuity test lead with a probe and crocodile clip.
The Kewtech EZYPAT PAT Tester is a simple yet comprehensive portable appliance tester. This lightweight, ergonomic instrument is ideal for those wishing to check extension leads, and Class I and Class II appliances without electronic on/off switches.
Key Features
- Battery operated PAT tester
- 200mA continuity
- 1-second quick check continuity test
- 5-second continuity test
- 250V DC insulation test
- 500V DC insulation test
- Substitute leakage test
- Polarity check
- Extension lead test
- Optimised for performing manual dead tests on extension leads, as well as Class I and Class II appliances without electronic on/off switches
- Pre-programmed automatic test sequences for extensions leads and Class I and Class II appliances
- Run the pre-programmed automatic test sequences for the above instruments via pressing dedicated, clearly labelled function buttons
- Entry-level model in Kewtech’s EZYPAT/SMARTPAT range
- Test Lead Null setting
- Appliance pre-check function
- IT safe
- Perform approximately 1400 tests over the course of the battery’s lifetime
- Large, backlit display
- Backlight turns green to indicate a PASS
- Backlight turns red to indicate a FAIL
- Supplied with an extension lead adapter and an earth continuity test lead with a probe and crocodile clip
- A simple yet comprehensive portable appliance tester
- Lightweight and ergonomic
- Use with the Kewtech KEWPAT App in Manual mode to collect data and create reports
- The Kewtech KEWPAT App is available for free download from the App Store (iOS) and Google Play (Android)
- Ideal for those wishing to check extension leads, and Class I and Class II appliances without electronic on/off switches
What’s Included?
- Kewtech EZYPAT PAT Tester (supplied by Kewtech)
- EZYLEAD Extension Lead Adapter (supplied by Kewtech)
- EZYEARTH Earth Continuity Test Lead with Probe and Crocodile Clip (supplied by Kewtech)
- Carry Bag with Strap (supplied by Kewtech)
- Quick Start Guide (supplied by Kewtech)
- Soft Shell Cary Case
- Socket Tester
- eLearning PAT Testing Course - Includes Exam and Certificate
- PASS PAT Testing Logbook
- Microwave Leakage Detector
- PASSPTA21 – IEC (C13 Female) to Cloverleaf (C6 Male) PAT Adapter
- PASSPTA29 – IEC Plug (C14) to Cloverleaf (C5) PAT Adapter
- PASSPTA28 – IEC Plug (C14) to Fig 8 (C7) PAT Adapter
- CK Tools AVO5050 5 Piece Insulated Screwdriver Set
- 500 x Passed PAT Testing Labels
- 500 x Circular Passed PAT Testing Labels
- 250 x Cable Wrap Labels
- 250 x Failed PAT Testing Labels
- SimplyPats Manual PAT Testing Software
The Kewtech EZYPAT PAT Tester is also available in another bundle, the Kewtech EZYPAT PAT Tester PAT Essentials Kit (Bundle 1). Please see the table below for an overview of the items included in both this bundle and Bundle 1.
Item Description | EZYPAT PAT Tester - PAT Essentials Kit (Bundle 1) | EZYPAT PAT Tester - PAT Professional Kit (Bundle 2) |
---|---|---|
Soft Shell Carrying Case Keep all of your equipment safe and in one place with this large-size carrying case with a customisable foam insert |
√ | √ |
Socket Tester Need to check if your sockets are working right? Just plug this into a standard UK plug socket and if there's a problem, the socket tester will let you know about it! |
√ | √ |
eLearning PAT Testing Course - Includes Exam and Certificate Gain a certificate of competency to carry out PAT testing in just two hours with our online PAT course and exam. Teams of staff may be trained by purchasing the course multiple times; each staff member will be assigned a unique activation code and login. |
√ |
√ |
PASS PAT Testing Logbook Keep a record of all of your tests with our logbook. The book includes carbon-copied records, allowing you to keep one for yourself and give the other to customers or keep for a reference. |
√ | √ |
Microwave Leakage Detector When PAT testing, it's common practice to check microwaves are also not emitting high levels of radiation. With our microwave leakage detector, you'll be able to do this testing with ease. |
√ | √ |
PASSPTA21 - IEC (C13 Female) You'll need this adapter to connect your PAT tester to laptop/PC power leads and other similar equipment which has a cloverleaf-shaped connector. |
√ | √ |
PASSPTA29 - IEC Plug (C14) This adaptor is used to connect to laptop power supplies, portable projectors and other similar equipment. |
√ | √ |
PASSPTA28 - IEC Plug (C14) You'll find several appliances such as game consoles, laptop power supplies, audio/visual equipment and more use this type of connector - with this adapter, you can connect them up to your PAT tester. |
√ | √ |
CK Tools AV05050 5 Piece Insulated Screwdriver Kit A handy set of insulated screwdrivers (suitable for live working to 1000V) suitable for a wide variety of applications. |
√ | √ |
WM1 - 500 x Passed PAT Testing Labels You'll need these every time an appliance passes a test - just tear one off, fill in the fields (appliance ID, your name, test date and next test due date) and stick on the appliance when done. |
√ | √ |
WM6500 - 500 x Circular Passed PAT Testing Labels These circular-shaped PAT labels are great for plug tops and any other appliance. The labels also include space for ticking the month/year the next test is due. |
√ | √ |
WM12 250 - 250 x Cable Wrap Labels These passed labels wrap around a wire/cable from an appliance and are recommended for use with power supplies or on appliances where you can't stick a label. They also include space for writing your appliance ID, name, test date and next test date. |
√ | √ |
WM7 250 - 250 x Failed PAT Testing Labels You won't need these as often as your passed labels, but you'll need to apply one of these whenever an appliance fails a test. If it does fail, the item should be taken out of service for repair or replacement |
√ | √ |
SimplyPats Manual PAT Testing Software Keep a database of your PAT testing information on your PC and print reports with SimplyPats Manual software. Please note that this software is manual entry; you cannot download directly from the PAT tester and you will need to type in records by hand. |
- | √ |
- PASS The Complete Guide to EET (PAT) Testing, 5th Edition - PASS-PAT-HB, typically £24.99
Kewtech EZYPAT/ SMARTPAT Comparision Table
Specification | EZYPAT | EZYPAT PLUS | SMARTPAT |
200mA Continuity Test | X | X | X |
250V Insulation Test | X | X | X |
500V Insulation Test | X | X | X |
Substitute Leakage Test | X | X | X |
Polarity Check | X | X | X |
110V Load and Run Test | X | X | |
230V Load and Run Test | X | X | |
Portable RCD Test | X | ||
Compatible with KEWPAT App | X | ||
Customisable Test Sequences | X |
Kewtech EZYPAT PAT Tester – Battery Operated Technical Specifications
Protective Conductor Resistance Test | |
Measuring Range | 0.00 - 20.00 Ω (NULL value inc)* |
Over-range Indication | > 20.00 Ω |
Resolution | 0.01Ω |
Open-circuit Voltage | 5 V ±0.4 V DC |
Measuring Current | 200 mA DC (nominal value) |
Accuracy | ±3%rdg ±5dgt |
* Resistances exceeding 3 Ω cannot be cancelled by NULL function. |
|
Insulation | |
Measuring Range | 0.00 - 20.00 MΩ |
Over-range Indication | > 20.00 MΩ |
Resolution | 0.01 MΩ |
No-load Voltage | 250V : 250 V DC +20%, -0% |
500V: 500 V DC +20%, -0% | |
Short-circuit Current | 1.5 mA DC or less |
Rated Current | 250V: 1 -1.2 mA with a load of 0.25 MΩ |
500V: 1 to 1.2 mA with a load of 0.5 MΩ | |
Accuracy | ±2%rdg±3dgt |
Substitute Leakage | |
Measuring Range | 0.10 - 12.00 mA rms |
Over-range Indication | > 12.00 mA |
Resolution | 0.01mA |
Open-circuit Voltage/ Frequency | 30 V ±5 V rms / 50 Hz ±5% |
Measuring Circuit | 1.2 mA AC ±0.5 mA (when measuring 12.00 mA) |
Accuracy | ±3%rdg±5dgt |
Insulation Testy Between L-N | |
Open-circuit Voltage | 4.5 V ±0.5 V DC |
Criteria of Judgement |
100 kΩ ±20 kΩ or less: LCD shows “<0.10 MΩ” and the measurement is halted. |
Physical Specifications | |
Safety |
IEC/EN61010-1 CAT II 300V-instrument |
EMC | EN61326-1, 2-2 |
Possible number of |
Approx. 1400 times |
Boxed Weight | 1.61Kg |
Boxed Dimensions (L x W x D) | 261 x 140 x 130mm |
Reviews
SKU | EZYPATBUNDLE2 |
---|---|
Manufacturer Part Code | EZYPATBUNDLE2 |