Kewtech EZYPAT-PLUS PAT Tester
The Kewtech EZYPAT-PLUS PAT Tester is an easy-to-use, non–downloading, battery operated PAT Tester optimised for testing Class I and Class II appliances, including items which require a power supply in order to be fully tested, i.e. appliances with electronic on/off switches such as computers and TVs. Furthermore, this PAT tester can also be used to examine extension leads.
The Kewtech EZYPAT-PLUS PAT Tester is the intermediate model in Kewtech’s range of new EZYPAT/ SMARTPAT PAT testers (for more information regarding these models please see the comparison table under the ‘Technical Specifications’). Therefore in addition to including all the tests and features found on the EZYPAT (available here), the EZYPAT-PLUS can also conduct leakage tests at 110V and 230V.
Measurement Capabilities
Like its sister product, the EZYPAT, this instrument can perform:
- 200mA earth continuity tests (IT safe)
- Appliance status pre-check (can be used to check whether the appliance under investigation is on or off)
- Quick continuity check (1 second)
- 5-second continuity check
- 250V DC insulation tests (IT safe)
- 500V DC insulation tests
- Substitute leakage tests (with selectable parameters)
- Extension lead tests
Moreover, the individually labelled function keys facilitate the user’s ability to run automatic test sequences customised for Class I and Class II appliances and extension leads; whilst the Kewtech EZYPAT-PLUS PAT Tester’s Test Lead Null setting ensures that insulation readings are not affected by the resistance found in the its test leads.
The accompanying EZYLEAD Extension Lead Adapter; EZYEARTH Earth Continuity Test Lead with Probe and Crocodile Clip and EZYMAIN Mains Lead all work to ensure that this PAT tester can be quickly and easily adapted to perform numerous tests in a variety of environments.
The results of these tests are clearly indicated on the Kewtech EZYPAT-PLUS PAT Tester’s large, easy-to-read, backlit display which turns red in the event of a failed test and green in the event of a passed one. The PAT Tester is also ergonomically designed and lightweight making it practical as well as versatile and easy-to-use. Its battery operation also adds to its practicality, as this PAT tester can perform up to approximately 1400 tests before the batteries begin to expire.
Overall the PAT tester is the ideal solution to intermediate PAT Testing requirements.
Key Features
- Non-downloading PAT tester optimised for testing Class I and Class II appliances as well as extension leads
- Battery-operated
- Suited to testing appliances with electronic on/off switches, i.e. items that need to be powered on in order to be fully tested
- Includes all the features found on the EZYPAT
- 200mA earth continuity tests (IT safe)
- Appliance status pre-check (can be used to check whether the appliance under investigation is on or off)
- Quick continuity check (1 second)
- 5-second continuity check
- 250V DC insulation tests (IT safe)
- 500V Dc insulation tests
- Substitute leakage tests (with selectable parameters)
- Extension lead tests
- IT safe
- EZYPAT-PLUS also performs leakage tests at 110V and 230V
- Individually labelled function keys allow the user to run tailored automatic test sequences
- Test Lead Null setting
- EZYLEAD Extension Lead Adapter
- EZYEARTH Earth Continuity Test Lead with Probe and Crocodile Clip
- EZYMAIN Mains Lead
- Large, easy-to-read, backlit display
- Display turns green when a test is passed
- Display turns red when a test is failed
- Ergonomic and lightweight
- Can perform up to 1400 tests before batteries begin to expire
- Use with the Kewtech KEWPAT App to collect data and create reports manually
- The Kewtech KEWPAT App is available for free download from the App Store (iOS) and Google Play (Android)
What’s Included?
- Kewtech EZYPAT-PLUS PAT Tester –Battery Operated
- EZYLEAD Extension Lead Adapter
- EZYEARTH Earth Continuity Test Lead with Probe and Crocodile Clip
- EZYMAIN Mains Lead
- Carry Bag with Strap
- Quick Start Guide
- End of Line Calibration Certificate
Kewtech PAT Tester Comparison
EZYPAT | EZYPAT Plus | SMARTPAT | |
---|---|---|---|
200mA continuity Test | Yes | ||
250V Insulation Test | Yes | ||
500V Insulation Test | Yes | ||
Substitute Leakage Measurement | Yes | ||
Polarity Check | Yes | ||
110V Load and Run Test | - | Yes | |
230V Load and Run Test | - | Yes | |
Portable RCD Test | - | - | Yes |
Compatible with KEWPAT App | - | Yes | |
Customisable Test Sequences | - | - | Yes |
Videos
PAT Test with Kewtech
Enjoy peace of mind with a Free PAT Card included with every purchase. Keep track of essential safety checks effortlessly!
- Essential Bundle (1,000 Labels & Logbook) - PAT-ESSENTIAL-BUNDLE, typically £77.98
- IT Bundle (3 x IEC Adaptors & Socket Tester) - PAT-IT-BUNDLE, typically £46.96
- Tolsen Tools 7-Piece Insulated Screwdriver Set - TS-9900012, typically £16.99
Kewtech EZYPAT/ SMARTPAT Comparision Table
Specification | EZYPAT | EZYPAT PLUS | SMARTPAT |
200mA Continuity Test | X | X | X |
250V Insulation Test | X | X | X |
500V Insulation Test | X | X | X |
Substitute Leakage Test | X | X | X |
Polarity Check | X | X | X |
110V Load and Run Test | X | X | |
230V Load and Run Test | X | X | |
Portable RCD Test | X | ||
Compatible with KEWPAT App | X | ||
Customisable Test Sequences | X |
Kewtech EZYPAT PAT Tester – Battery Operated Technical Specifications
Protective Conductor Resistance Test | |
Measuring Range | 0.00 - 20.00 Ω (NULL value inc)* |
Over-range Indication | > 20.00 Ω |
Resolution | 0.01Ω |
Open-circuit Voltage | 5 V ±0.4 V DC |
Measuring Current | 200 mA DC (nominal value) |
Accuracy | ±3%rdg ±5dgt |
* Resistances exceeding 3 Ω cannot be cancelled by NULL function. |
|
Mains Voltage | |
Display Range | 30 - 270 V |
Hi/Lo Indication |
< 30 V: No voltage indication |
Resolution & Accuracy | 1 V ±3%rdg ±5dgt |
Insulation | |
Measuring Range | 0.00 - 20.00 MΩ |
Over-range Indication | > 20.00 MΩ |
Resolution | 0.01 MΩ |
No-load Voltage | 250V : 250 V DC +20%, -0% |
500V: 500 V DC +20%, -0% | |
Short-circuit Current | 1.5 mA DC or less |
Rated Current | 250V: 1 -1.2 mA with a load of 0.25 MΩ |
500V: 1 to 1.2 mA with a load of 0.5 MΩ | |
Accuracy | ±2%rdg±3dgt |
Substitute Leakage | |
Measuring Range | 0.10 - 12.00 mA rms |
Over-range Indication | > 12.00 mA |
Resolution | 0.01mA |
Open-circuit Voltage/ Frequency | 30 V ±5 V rms / 50 Hz ±5% |
Measuring Circuit | 1.2 mA AC ±0.5 mA (when measuring 12.00 mA) |
Accuracy | ±3%rdg±5dgt |
Insulation Testy Between L-N | |
Open-circuit Voltage | 4.5 V ±0.5 V DC |
Criteria of Judgement |
100 kΩ ±20 kΩ or less: LCD shows “<0.10 MΩ” and the measurement is halted. |
Run Leakage | |
Mains Voltage Range | 100 - 253 V / 50 Hz |
Measuring Range | Load Current: 0.10 - 13.00 A rms |
Leakage Current: 0.10 - 20.00 mA rms | |
Display Range | Load Current: 0.00 - 13.00 A |
Leakage Current: 0.00 - 20.00 mA | |
Over-range Indication | Load Current: > 13.00 A |
Leakage Current: > 20.00 mA | |
Resolution | Load Current: 0.01A |
Leakage Current: 0.01mA | |
Accuracy | Load Current: ±10%rdg ±5dgt |
Leakage Current: ±3%rdg ±5dvgt | |
Max. Rating | Load Current: 3 kVA max. / 15 sec. cont. |
Leakage Current: - | |
Physical Specifications | |
Safety |
IEC/EN61010-1 CAT II 300V-instrument |
EMC | EN61326-1, 2-2 |
Possible number of |
Approx. 1400 times |
Boxed Weight | 1.82Kg |
Boxed Dimensions (L x W x D) | 261 x 140 x 130mm |