Looking around for a great entry-level PAT kit? Our HPAT600/2 bundle 1 is perfect for those new to the industry, or those simply looking for an easy-to-use tester that does everything with minimal fuss.
Our PAT testing kits are completely exclusive to us. We've put them together to give those interested in PAT testing all the equipment they need for a vastly reduced price without the hassle of buying everything separately.
In this bundle, you'll receive all standard manufacturer-issued items:
You will also receive an additional pack from us which includes:
The upgraded version of the Martindale HPAT500/2, the HPAT600/2 includes built-in non-downloadable memory, making it easier to manage your testing results.
Simple and easy to use, the HPAT600/2 is one of the smallest testers on the market, making it ideal for testing appliances round offices, in shops and other low-volume applications.
Not sure if this is the right kit for you? We also have several other kits available for the HPAT600/2.
This table outlines the difference between each.
Item Description | HPAT600/2 PAT Tester Essentials Kit (Bundle 1) | HPAT600/2 PAT Tester Professional Kit (Bundle 2) |
---|---|---|
Deluxe Carrying Case Keep all of your equipment safe and in one place with this large-size carrying case! (appearance of case may vary depending on current stock) |
√ | √ |
Socket Tester Need to check if your sockets are working right? Just plug this in to a standard UK plug socket and if there's a problem, the socket tester will let you know about it! |
√ | √ |
eLearning PAT Testing Course - Includes Exam and Certificate Gain a certificate of competency to carry out PAT testing in just two hours with our online PAT course and exam. Teams of staff may be trained by purchasing the course multiple times; each staff member will be assigned a unique activation code and login. |
√ |
√ |
PASS PAT Testing Logbook Keep a record of all of your testing with our logbook. The book includes carbon-copied records, allowing you to keep one for yourself and give the other to customers or keep for a reference. |
√ | √ |
Microwave Leakage Detector When PAT testing, it's common practice to check microwaves are also not emitting high levels of radiation. With our microwave leakage detector you'll be able to do this testing with ease. |
√ | √ |
PASSPTA21 - IEC (C13 Female) You'll need this adaptor to connect your PAT tester to laptop/PC power leads and other similar equipment which has a cloverleaf-shaped connector. |
√ | √ |
PASSPTA29 - IEC Plug (C14) This adaptor is used to connect to laptop power supplies, portable projectors and other similar equipment. |
√ | √ |
PASSPTA28 - IEC Plug (C14) You'll find several appliances such as game consoles, laptop power supplies, audio/visual equipment and more use this type of connector - with this adaptor, you can connect them up to your PAT tester. |
√ | √ |
CK Tools AV05050 5 Piece Insulated Screwdriver Kit A handy set of insulated screwdrivers (suitable for live working to 1000V) suitable for a wide variety of applications. |
√ | √ |
WM1 - 500 x Passed PAT Testing Labels You'll need these every time an appliance passes a test - just tear one off, fill in the fields (appliance ID, your name, test date and next test due date) and stick on the appliance when done. |
√ | √ |
WM6500 - 500 x Circular Passed PAT Testing Labels These circular-shaped PAT labels are great for plug tops and any other appliance. The labels also include space for ticking the month/year the next test is due. |
√ | √ |
WM12 250 - 250 x Cable Wrap Labels These passed labels wrap around a wire/cable from an appliance and are recommended for use with power supplies or on appliances where you can't stick a label. They also include space for writing your appliance ID, name, test date and next test date. |
√ | √ |
WM7 250 - 250 x Failed PAT Testing Labels You won't need these as often as your passed labels, but you'll need to apply one of these whenever an appliance fails a test. If it does fail, the item should be taken out of service for repair or replacement |
√ | √ |
SimplyPats Manual PAT Testing Software Keep a database of your PAT testing information on your PC and print reports with SimplyPats Manual software. Please note that this software is manual entry; you cannot download directly from the PAT tester and you will need to type in records by hand. |
- | √ |
Earth Continuity | |
Test Voltage | 4V DC (into open circuit) |
Test Current | 200mA DC (into short circuit) |
Range | 0 to 19.99Ω |
Resolution | 0.01Ω |
Accuracy | ± (5% of reading + 2 digits) |
Fixed Pass Limits | |
Lead | ≤ 0.10 Ω = PASS > 0.10Ω ≤ 0.20Ω = NOTE x.xx PASS* |
Class I | Class I ≤ 0.10 Ω = PASS > 0.10Ω ≤ 0.20Ω = NOTE x.xx PASS* |
Note | *Allows user defined pass values to be recorded, eg. for long cord lengths. |
User settable limits | ≤0.1Ω to ≤0.9Ω in 0.1Ω steps |
Insulation | |
Test Voltage | User selectable > 250V DC at 1mA / > 500V DC at 1mA (< 312.5V DC open circuit / < 625V DC open circuit) |
Test Current | Test current: 1.5mA (into short circuit) |
Ranges | 2.00MΩ, 20.0MΩ, 200MΩ |
Resolution | 0.01MΩ |
Accuracy | <100MΩ ± (5% reading + 2 digits) >100MΩ ± (10% reading + 2 digits) |
Fixed Pass Levels | Lead: ≥ 1.0 MΩ Class I: ≥ 1.0 MΩ Class II: ≥ 2.0 MΩ |
Pass level | Lead: ≥ 1.0MΩ, Class I: ≥ 1.0MΩ, Class II: ≥ 2.0MΩ |
User Settable PASS level | ≥ 0.3MΩ to ≥ 1MΩ in 0.1MΩ steps ≥ 1MΩ to ≥ 10MΩ in 1MΩ steps |
Fuse Checks | |
Test Voltage | 4V DC (into open circuit) |
Test Current | 200mA DC (into short circuit) |
Pass Level | >2mA |
Simulatted Load Test | |
Test voltage | 4V DC (into open circuit) |
Test current | 200mA DC (into short circuit) |
Accuracy | ± (5% reading + 2 digits) |
Threshold for ‘Simulated Current Hi’ | 16A |
Memory | 200 tests stored for on-screen recall |
General | |
Overload Protection | 300V AC/DC |
Protection class | IP20 |
Safety | Complies to BS EN 61010-1 |
Temperature Range | -10 to 40°C, non-condensing |
Batteries | 6 x 1.2V AA NiMH rechargeable batteries 1800mAh, or greater |
Battery Life | Fully charged, minimum 600 complete tests. The HPAT500 will operate fully from the battery charger in the event of discharged batteries. Do not remove batteries. |
Auto Shut Down | After 10 minutes of inactivity, or when battery low |
Battery Charger Input | 230V 50Hz |
Battery Charger Output | 12VDC at 300mA, 5.5 jack x 2.5 bore centre positive |
Dimensions | 90 x 210 x 54mm |
Weight | Approx 700g (including batteries & leads) |