The HPAT500/2 is designed to streamline the PAT testing process, offering simplicity with its small, battery-powered design and one-button operation. This versatile tester is suitable for both 240V and 110V appliances (adapter lead required) and can perform class I, class II, and power lead testing procedures. It includes a dedicated IT-safe 200mA DC earth bond test with two pass levels for sensitive IT equipment. Unlike entry-level PAT testers, the HPAT500/2 features a PASS/FAIL indicator on its high-contrast, backlit screen and displays full test readings for record-keeping in the included logbook. Get your hands on this efficient and reliable PAT tester bundle pack today!
Both manufacturer's and our own accessories are listed.
You'll also get the following PAT essential accessories:
Interested in the HPAT500/2? Why not also upgrade straight to bundle 2, which comes with everything you see here plus software and a deluxe carrying case?
Item Description | HPAT500/2 PAT Tester Essentials Kit (Bundle 1) | HPAT500/2 PAT Tester Professional Kit (Bundle 2) |
---|---|---|
Soft Shell Carrying Case Keep all of your equipment safe and in one place with this large-size carrying case with a customisable foam insert
|
√ | √ |
Socket Tester Need to check if your sockets are working right? Just plug this in to a standard UK plug socket and if there's a problem, the socket tester will let you know about it! |
√ | √ |
eLearning PAT Testing Course - Includes Exam and Certificate Gain a certificate of competency to carry out PAT testing in just two hours with our online PAT course and exam. Teams of staff may be trained by purchasing the course multiple times; each staff member will be assigned a unique activation code and login. |
√ |
√ |
PASS PAT Testing Logbook Keep a record of all of your testing with our logbook. The book includes carbon-copied records, allowing you to keep one for yourself and give the other to customers or keep for a reference. |
√ | √ |
Microwave Leakage Detector When PAT testing, it's common practice to check microwaves are also not emitting high levels of radiation. With our microwave leakage detector you'll be able to do this testing with ease. |
√ | √ |
PASSPTA21 - IEC (C13 Female) You'll need this adaptor to connect your PAT tester to laptop/PC power leads and other similar equipment which has a cloverleaf-shaped connector. |
√ | √ |
PASSPTA29 - IEC Plug (C14) This adaptor is used to connect to laptop power supplies, portable projectors and other similar equipment. |
√ | √ |
PASSPTA28 - IEC Plug (C14) You'll find several appliances such as game consoles, laptop power supplies, audio/visual equipment and more use this type of connector - with this adaptor, you can connect them up to your PAT tester. |
√ | √ |
CK Tools AV05050 5 Piece Insulated Screwdriver Kit A handy set of insulated screwdrivers (suitable for live working to 1000V) suitable for a wide variety of applications. |
√ | √ |
WM1 - 500 x Passed PAT Testing Labels You'll need these every time an appliance passes a test - just tear one off, fill in the fields (appliance ID, your name, test date and next test due date) and stick on the appliance when done. |
√ | √ |
WM6500 - 500 x Circular Passed PAT Testing Labels These circular-shaped PAT labels are great for plug tops and any other appliance. The labels also include space for ticking the month/year the next test is due. |
√ | √ |
WM12 250 - 250 x Cable Wrap Labels These passed labels wrap around a wire/cable from an appliance and are recommended for use with power supplies or on appliances where you can't stick a label. They also include space for writing your appliance ID, name, test date and next test date. |
√ | √ |
WM7 250 - 250 x Failed PAT Testing Labels You won't need these as often as your passed labels, but you'll need to apply one of these whenever an appliance fails a test. If it does fail, the item should be taken out of service for repair or replacement |
√ | √ |
SimplyPats Manual PAT Testing Software Keep a database of your PAT testing information on your PC and print reports with SimplyPats Manual software. Please note that this software is manual entry; you cannot download directly from the PAT tester and you will need to type in records by hand. |
- | √ |
Earth Continuity | |
Test Voltage | 4V DC (into open circuit) |
Test Current | 200mA DC (into short circuit) |
Range | 0 to 19.99Ω |
Resolution | 0.01Ω |
Accuracy | ± (5% of reading + 2 digits) |
Fixed Pass Limits | |
Lead | ≤ 0.10 Ω = PASS > 0.10Ω ≤ 0.20Ω = NOTE x.xx PASS* |
Class I | Class I ≤ 0.10 Ω = PASS > 0.10Ω ≤ 0.20Ω = NOTE x.xx PASS* |
Note | *Allows user defined pass values to be recorded, eg. for long cord lengths. |
Insulation | |
Test Voltage | User selectable > 250V DC at 1mA / > 500V DC at 1mA (< 312.5V DC open circuit / < 625V DC open circuit) |
Test Current | Test current: 1.5mA (into short circuit) |
Ranges | 2.00MΩ, 20.0MΩ, 200MΩ |
Resolution | 0.01MΩ |
Accuracy | <100MΩ ± (5% reading + 2 digits) >100MΩ ± (10% reading + 2 digits) |
Fixed Pass Levels | Lead: ≥ 1.0 MΩ Class I: ≥ 1.0 MΩ Class II: ≥ 2.0 MΩ |
Pass level | Lead: ≥ 1.0MΩ, Class I: ≥ 1.0MΩ, Class II: ≥ 2.0MΩ |
Fuse Checks | |
Test Voltage | 4V DC (into open circuit) |
Test Current | 200mA DC (into short circuit) |
Pass Level | >2mA |
General | |
Overload Protection | 300V AC/DC |
Protection class | IP20 |
Safety | Complies to BS EN 61010-1 |
Temperature Range | -10 to 40°C, non-condensing |
Batteries | 6 x 1.2V AA NiMH rechargeable batteries 1800mAh, or greater |
Battery Life | Fully charged, minimum 600 complete tests. The HPAT500 will operate fully from the battery charger in the event of discharged batteries. Do not remove batteries. |
Auto Shut Down | After 10 minutes of inactivity, or when battery low |
Battery Charger Input | 230V 50Hz |
Battery Charger Output | 12VDC at 300mA, 5.5 jack x 2.5 bore centre positive |
Dimensions | 90 x 210 x 54mm |
Weight | Approx 700g (including batteries & leads) |