All HD Electric Company Products

HD Electric TILT II Transformer Testers

SKU
HD-TL-XXX-Y
Rating:
0%
(0)
Call For Pricing

We require additional information before you purchase this product

or Call 01642 931 329 to discuss product options

HD Electric TILT II Transformer Testers

The HD Electric TILT II Transformer Tester can be used to check de-energised transformers for major defects before energising. Testing transformers with this tool can prevent line workers from installing a fuse on shortened transformers.

There are four versions of the HD Electric TILT II Transformer Tester available: two with a manual self-test and two with an automatic self-test. Manual self-test versions feature tabs on the side of the unit allowing the user to verify the HD Electric TILT II Transformer Tester’s functionality as required; automatic self-test models will check the battery, lights, beeper and electronics each time the TEST button is pressed.

Each of these models is supplied with large copper alligator clips with heavy-duty boots and heavy-duty rubber insulated coiled test leads. Select models are also supplied with a magnet (see the ‘What’s Included?’ section for further details) allowing the user to connect the HD Electric TILT II Transformer Tester to the exterior of units/ machinery thereby facilitating hands-free operation.

The HD Electric TILT II Transformer Tester is equipped with a simple-to-use single-button operating system; it will continually run tests for as long as this button is pressed. The HD Electric TILT II Transformer Tester is suitable for the following applications:

  • Quickly and easily checking transformers and their connections
  • Testing the primary and secondary sides of new, reworked, single- or three-phase transformer installations for short circuits before energising
  • Testing the primary and secondary sides of de-energised transformers without disconnecting these units
  • Testing the secondary sides of transformers and all the connections made to this side (up to and including the meter) before energising
  • Quickly verifying whether secondary connections are shorted
  • Screening incoming and outgoing transformers for primary and secondary shorts or opens (including internal fuses and breakers) before energising

The HD Electric TILT II Transformer Tester is suitable for checking 1Ø and 3Ø overhead, pad-mounted and potential transformers as well as other distribution transformers.

The HD Electric TILT II Transformer Tester will indicate whether a short circuit or open circuit has been detected via super bright LEDs; it will also offer a clear visual and audible indication when test results are OK. The HD Electric TILT II Transformer Tester can differentiate between a true short and a low instance of transformer winding.

The HD Electric TILT II Transformer Tester is a compact, lightweight, easy-to-use high-voltage instrument suitable for quickly and easily testing power distribution systems for shorts and opens. For further information regarding the HD Electric TILT II Transformer Tester, please see the following video.

HD Electric TILT II Transformer Testers Key Features

  • Check de-energised transformers for major defects before energising
  • Prevent line workers from installing a fuse on shortened transformers
  • Four versions: two with manual self-test, two with automatic self-test
  • Manual self-test models feature tabs on the side of the unit
  • Automatic self-test models automatically check the battery, lights, beeper and electronics each time the TEST button is pressed
  • Supplied with large copper alligator clips with heavy-duty boots
  • Heavy-duty rubber insulated coiled test leads
  • Select models are supplied with a magnet (see ‘What’s Included?’)
  • The magnet can be used to attach the tester to the exterior of units/ machinery facilitating hands-free usage
  • Simple-to-use single-button operating system
  • Continually performs tests as long as the TEST button is pressed
  • Quickly and easily check transformers and their connections
  • Test the primary and secondary sides of new, reworked, single- or three-phase transformer installations for short circuits before energising
  • Test the primary and secondary sides of de-energised transformers without disconnecting these units
  • Test the secondary sides of transformers and all the connections made to this side (up to and including the meter) before energising
  • Quickly verify whether secondary connections are shorted
  • Screen incoming and outgoing transformers for primary and secondary shorts or opens (including internal fuses and breakers) before energising
  • Check 1Ø and 3Ø overhead, pad-mounted and potential transformers, as well as other distribution transformers
  • Super bright LEDs
  • LED indicators for open circuits and short circuits
  • Issues a visual and audible alert when test results are OK
  • Able to differentiate between a true short and a low instance of transformer winding
  • Powered by a 9V lithium/ alkaline battery
  • A compact, lightweight, easy-to-use high voltage instrument
  • Suitable for quickly and easily testing power distribution systems for shorts and opens

What’s Included?

HD Electric TILT II Transformer Tester with Manual Self-Test

  • HD Electric TILT II Transformer Tester with Manual Self-Test
  • HD Electric B-8 Padded Carrying Case
  • Instruction Manual

HD Electric TILT II Transformer Tester with Manual Self-Test & Magnet

  • HD Electric TILT II Transformer Tester with Manual Self-Test
  • Magnet
  • HD Electric B-8 Padded Carrying Case
  • Instruction Manual

HD Electric TILT II Transformer Tester with Automatic Self-Test

  • HD Electric TILT II Transformer Tester with Automatic Self-Test
  • HD Electric B-8 Padded Carrying Case
  • Instruction Manual

HD Electric TILT II Transformer Tester with Automatic Self-Test & Magnet

  • HD Electric TILT II Transformer Tester with Automatic Self-Test
  • Magnet
  • HD Electric B-8 Padded Carrying Case
  • Instruction Manual

Model Overview 

Products Model
HD-TL-MAN-N HD-TL-MAN-M HD-TL-AST-N HD-TL-AST-M
HD Electric TILT II Transformer Tester with Manual Self-Test X X
HD Electric TILT II Transformer Tester with Automatic Self-Test X X
Magnet X X
HD Electric B-8 Padded Carrying Case X X X X
Instruction Manual X X X X

HD Electric TILT II Transformer Testers Technical Specifications 

SHORT ≤ 10Ω varies with battery voltage
OPEN ≥ 10Ω varies with battery voltage
Transformer O.K Minimum inductance 800µH
Capacitor O.K Minimum capacitance 0.5µf
Maximum capacitance 300µf
Dimensions 5.75”x 3.5”x 1.5” (14.60 cm x 8.89 cm x 3.81cm)
Test Leads 21”(53.34 cm) retracted,
54”(137.16 cm) fully extended
Battery Powered by a 9V lithium or alkaline battery
Weight TILT II 1lb.,1oz. (0.47 kg)
TILT II with magnet 1lb., 2 oz. (0.51 kg)
HD Electric TILTII and Quick-Check Transformer & Capacitor Testers - Datasheets Datasheets HD Electric TILT II & Quick-Check Transformer & Capacitor Testers with Automatic Self-Test - User Manual Manuals & Guides HD Electric TILT II & Quick-Check Transformer & Capacitor Testers with Manual Self-Test - User Manual Manuals & Guides

Reviews

Additional Information
SKU HD-TL-XXX-Y
Manufacturer Part Code TL-AST-N