HD Electric Hi-Test MOV Arrester and Leakage Tester – 15kV AC

The HD Electric Hi-Test MOV Arrester and Leakage Tester is a high voltage tester with a limited current. It can be used for a range of troubleshooting, quality assurance, cost-saving and training applications.

The two options listed in the drop-down menu differ in regards to the voltage of the charging adapter included with each unit. Please see the ‘What’s Included?’ section for further information.

The HD Electric Hi-Test MOV Arrester and Leakage Tester -15kV AC can be used to test MOV arresters up to a 15kV AC class; please note that this instrument cannot be used to test gap type or hybrid MOV/ gap type arresters such as Hubbell Optima and Cooper VariGAP. This instrument is also capable of testing fuses, transformer bushings and tank lids, as well as bell type, distribution class polymers, and cross arm pin insulators that are within the HD Electric Hi-Test MOV Arrester and Leakage Tester’s voltage range. The HD Electric Hi-Test MOV Arrester and Leakage Tester has a DC output voltage range of 0 to 21 kV.

The HD Electric Hi-Test MOV Arrester and Leakage Tester is designed to perform safe, non-destructive tests and can be used to troubleshoot the causes of blinking lights and radio and television interference: these problems are often caused by non-visible damage to arresters and distribution boards. It is also possible to test MOV arresters for shorts and sparkover voltages using the HD Electric Hi-Test MOV Arrester and Leakage Tester.

Tests are conducted by connecting the HD Electric Hi-Test MOV Arrester and Leakage Tester’s test leads to the top and bottom of the instrument-under-investigation, a DC voltage is then applied to the component. To determine the exact voltage at which an arrester conducts the user can alter the potential difference that is applied. The applied voltage, as well as the measured leakage current, are viewable via the dedicated bright, easy-to-read LED displays.

The LED display for voltage indicates DC voltages with AC equivalent increments, whilst the LED scale for leakage current increases in increments of 5mA up to 50mA; if the current exceeds the upper limit the HD Electric Hi-Test MOV Arrester and Leakage Tester will show a ‘full-on’ display. Via these displays, the user can see the current leakage for any applied voltage. He/she can also use the HD Electric Hi-Test MOV Arrester and Leakage Tester to determine the maximum voltage that the arrester can support when at full conduction.

As the user is able to increase the amount of voltage applied to the instrument-under-investigation, the HD Electric Hi-Test MOV Arrester and Leakage Tester can be used to demonstrate the function and behaviour of arresters and other components when the potential difference is increased.

Additionally, the testing capabilities of the HD Electric Hi-Test MOV Arrester and Leakage Tester makes it suitable for ascertaining the quality of new arresters and insulators prior to installation. It can also be used to identify arresters and insulators that are functional and may be reused. This allows the user to manage his/her materials budget more effectively.

The portable, lightweight design of the HD Electric Hi-Test MOV Arrester and Leakage Tester makes it suitable for use across various locations, including on-site, in transformer rebuild shops, maintenance yards, and training facilities.

Additionally, to facilitate handsfree usage, this instrument is supplied with a pivoting handle and belt clip. It can be used for three to five days without recharge due to the inclusion of a sealed, lead-acid, rechargeable 12V DC battery. The Auto Shut-off feature also ensures that battery life is preserved when the HD Electric Hi-Test MOV Arrester and Leakage Tester is not in operation.

The HD Electric Hi-Test MOV Arrester and Leakage Tester is an ergonomic, easy-to-use and effective high voltage, limited-current, non-destructive tester. It can be used to troubleshoot and asses MOV arresters, insulators and various other components safely, as well as demonstrate the functions and behaviours of this equipment.

HD Electric Hi-Test MOV Arrester and Leakage Tester – 15kV AC Key Features

  • A high-voltage tester with a limited current
  • Suitable for troubleshooting, quality assurance, cost-saving and training applications
  • Options differ in regards to the voltage of the charging adapter included with each unit
  • Test MOV arresters up to a 15kV AC class
  • CANNOT be used to test gap type or hybrid MOV/ gap type arresters such as Hubbell Optima and Cooper VariGAP
  • Test fuses, transformer bushings and tank lids
  • Test bell type, distribution class polymers, and cross arm pin insulators within the unit’s voltage range
  • DC output voltage range: 0-21kV
  • Perform safe, non-destructive tests
  • Troubleshoot the causes of blinking lights, and radio and television interference
  • Find non-visible damage
  • Test MOV arresters for shorts and sparkover voltages
  • Equipped with two test leads which are connected to the top and bottom of the arrester
  • A voltage is passed through the arrester
  • Alter the applied potential difference to determine the exact voltage at which an arrester conducts
  • Two bright, easy-to-read LED scales: one for applied voltage, one for the measured leakage current
  • The LED display for voltage indicates DC voltages with AC equivalent increments
  • The LED scale for leakage current goes up to 50mA in 5ma increments
  • When a leakage current in excess of 50mA is detected a ‘full-on’ display will show
  • See the current leakage for any applied voltage
  • Determine the maximum voltage the arrester can support when at full conduction
  • Can be used to demonstrate the function and behaviour of arresters and other components when voltage is increased
  • Assess the quality of new arresters and insulators prior to installation
  • Identify functional arresters and insulators that may be reused
  • Allows the user to manage his/her materials budget more effectively
  • Portable and lightweight
  • Suitable for use on-site, in transformer rebuild shops, maintenance yards and training facilities
  • Supplied with a pivoting handle and belt clip facilitating handsfree use
  • Sealed, lead-acid, rechargeable, 12V DC battery that can provide 3-5 days of power from a single charge
  • Auto Shut-off
  • An ergonomic, easy-to-use and effective high voltage, limited-current, non-destructive tester
  • Troubleshoot and asses MOV arresters and insulators safely
  • Demonstrate the functions and behaviours of MOV arresters, insulators and other HV components

What’s Included?

HD Electric Hi-Test HISAT-15 MOV Arrester and Leakage Tester

  • HD Electric Hi-Test MOV Arrester and Leakage Tester – 15kV AC
  • Battery
  • High-Voltage Test Lead
  • Ground Return Lead
  • Static Ground Lead
  • 120V AC Charging Adapter

HD Electric Hi-Test HISAT-15/220P MOV Arrester and Leakage Tester

  • HD Electric Hi-Test MOV Arrester and Leakage Tester – 15kV AC
  • Battery
  • High-Voltage Test Lead
  • Ground Return Lead
  • Static Ground Lead
  • 220V AC Charging Adapter

HD Electric Hi-Test MOV Arrester and Leakage Tester – 15kV AC Technical Specifications 

DC Output Voltage Range 0-21kV
Arrester Classes  Up to 15kV AC
Common Arrester Ratings That Can Be Tested 3, 6, 9, 10*, 12*, 15*kV
Voltage Resolution  700 VDC
Dimensions 12" x 5" x 8"(31 cm x 13 cm x 20 cm)
Note *Tests for sparkover voltage on MOV types only