Hanna Instruments HI-98194 Multiparameter Waterproof Meter

All Hanna Instruments Products
  • Colour coded, field replaceable sensors
  • Auto sensor recognition
  • Automatic logging of up to 45,000 samples
SKU
HI-98194
MPN
HI-98194

Read More

View All pH Meters & Water Quality Testers

The Hanna HI-98194 Multiparameter Meter can measure up to 12 critical parameters. These include pH, ORP, conductivity, TDS, resistivity, salinity, dissolved oxygen, temperature, and atmospheric pressure. It has a waterproof IP67 enclosure and is suitable for environmental fieldwork, aquaculture, and wastewater analysis.

The HI-7698194 quick-connect probe features field-replaceable sensors and includes a 4-metre cable. Other features of the HI-98194 include a backlit graphic LCD screen, an on-board Help Menu, and data logging capabilities, with space for up to 45,000 samples. Data is transferable to a PC through the HI-920015 micro USB cable and Hanna software.

Key Features

  • IP67-rated waterproof, rugged enclosure for meter, IP68 for probe
  • Colour-coded, field replaceable sensors
  • Auto sensor recognition
  • Rugged Carrying Case
  • Automatic logging of up to 45,000 samples
  • Store measurement data at the press of a button
  • On-screen context-specific help is readily available at the press of a button
  • PC connectivity via opto-isolated micro-USB with Hanna software
  • Up to 360 hours of battery life, powered by (4) 1.5V batteries
  • pH specific
    • Up to three-point calibration with five standard buffers and one custom buffer available
  • EC/TDS/Resistivity specific
    • Single point calibration from six standards (84?S/cm, 1413 ?S/cm, 5.00 mS/cm, 12.88 mS/cm, 80 mS/cm, 111.8 mS/cm)
    • Automatic temperature compensation, configurable temperature coefficient range from 0.00 to 6.00%/°C
    • Choice of reference temperatures at 20 or 25°C
    • Absolute conductivity can be displayed along with the temperature-compensated value
    • Auto ranging
    • Practical Salinity Scale (PSU)based on conductivity calibration
  • Dissolved Oxygen specific
    • Display units in % saturation of mg/L (ppm)
    • Salinity compensation for concentration
    • Pressure compensation for concentration
    • Built-in barometer with user-selectable units (mmHg, inHg, atm, psi, kPa, mbar)
    • Temperature compensation
    • Automatic polarisation of the probe at startup
    • Ready-to-use HDPE pre-tensioned membrane caps are easy to replace
  • Setup screen - a host of configurable options such as time, date, temperature units and different languages for help screens and guides
  • Quick Calibration - a single-point calibration for pH, conductivity, and dissolved oxygen
  • Probe specifics
    • Multiparameter pH/EC/DO/Temperature probe
    • Waterproof connection
    • Multistrand-multiconductor shielded cable
    • IP68 sensor

What's Included?

  • Multiparameter Waterproof Meter
  • HI-7698194 probe with 4m cable
  • HI-7698194-1 pH/ORP sensor
  • HI-7698194-3 EC sensor
  • HI-76981942 Probe maintenance kit
    • HI-7042S DO electrolyte solution
    • DO membrane caps (5)
    • O-rings for sensors (5)
    • Syringe with grease to lubricate the O-rings
  • HI-7698194-2 DO sensor
  • HI-9298194 Hanna PC software
  • HI-920015 micro USB cable
  • 1.5V AA batteries (4)
  • Instruction manual
  • Quick start guide
  • Quality certificate
  • Rugged carrying case with custom thermo-formed insert
£1,925.50
£2,310.60 inc vat
Free Delivery*
Important Notice
This item is made-to-order exclusively for you once your order is placed. As a result, it is not eligible for cancellation or return under our standard policy. Your statutory rights remain unaffected.
1925 Reward Points 60 Days Return

Ask An Expert
Price Match
Technical Information
Specification
pH/mV Range 0.00 to 14.00 pH/± 600.0 mV
Resolution 0.01 pH/ 0.1 mV
Accuracy ±0.02 pH/ ±0.5 mV
Calibration automatic one, two or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer
ORP Range ±2000.0 mV
ORP Resolution 0.1 mV
ORP Accuracy ±1.0 mV
ORP Calibration automatic at one custom point (relative mV)
EC Range 0 to 200 mS/cm (absolute EC up to 400 mS/cm)
EC Resolution Manual:
1μS/cm
0.001 mS/cm
0.01 mS/cm
0.1 mS/cm
Automatic:
1μS/cm from 0 to 9999 μS/cm
0.01 mS/cm from 10.00 to 99.99 mS/cm
0.1 mS/cm from 100.0 to 400.0 mS/cm
Automatic mS/cm:
0.001 mS/cm from 0.000 to 9.999 mS/cm
0.01 mS/cm from 10.00 to 99.99 mS/cm
0.1 mS/cm from 100.0 to 400.0 mS/cm
EC Accuracy ±1% of reading or ± 1μS/cm whichever is greater
EC Calibration automatic single point, with six standard solutions (84μS/cm, 1413μS/cm, 5.00mS/cm, 12.88 mS/cm, 80.0 mS/cm, 111.8 mS/cm) or custom point
TDS Range 0 to 400.0 ppt (g/L) (the maximum value depends on the TDS factor)
TDS Resolution Manual:
1 ppm (mg/L)
0.001 ppt (g/L)
0.1 ppt (g/L)
1 ppt (g/L)
Automatic:
1ppm (mg/L) from 0 to 9999 ppm (mg/L)
0.01 ppt (g/L) from 10.00 to 99.99 ppt (g/L)
0.1 ppt (g/L) from 100.0 to 400.0 ppt (g/L)
Automatic ppt (g/L):
0.001 ppt (g/L) from 0.000 to 9.999 PPT(g/L) from 10.00 to 99.99 ppt (g/L)
0.1 ppt (g/L) from 100.0 to 400.0 pp (g/L)
TDS Accuracy ±1% of reading or ±1 ppm (mg/L) whichever is greater
TDS Calibration based on conductivity or salinity calibration
Resistivity Range 0 to 999999 Ω.cm
0 to 1000.0 kΩ.cm
0 to 1.0000 MΩ.cm
Resistivity Resolution dependent on the resistivity reading
Resistivity Calibration based on conductivity or salinity calibration
Salinity Range 0.00 to 70.00 PSU
Salinity Resolution 0.01 PSU
Salinity Accuracy ±2% of reading or ±0.01 PSU whichever is greater
Salinity Calibration based on conductivity calibration
Seawater σ Range 0.0 to 50.0 σt, σ0, σ15
Seawater σ Resolution 0.1 σ t, σ0, σ 15
Seawater σ Accuracy ±1 σ t, σ0, σ 15
Seawater σ Calibration based on conductivity or salinity calibration
Dissolved Oxygen Range 0.0 to 500.0%
0.00 to 50.00 ppm
DO Resolution 0.1%
0.01 ppm (mg/L)
DO Accuracy 0.0 to 300.0%
±1.5% of reading or ±1.0% whichever is greater
300.0 to 500.0%
±3% of reading
0.00 to 30.00 ppm (mg/L)
±1.5% of reading or ±0.10 ppm (mg/L). whichever is greater
30.00 ppm (mg/L) to 50.00 ppm (mg/L)
±3% of reading
DO Calibration automatic one or two points at 0.100% or one custom point
Atmospheric Pressure Range 450 to 850 mm Hg
17.72 to 33.46 in Hg
600.0 to 1133.2 mbar
8.702 to 16.436 psi
0.5921 to 1.1184 atm
60.00 to 113.32 kPa
Atmospheric Pressure Resolution 0.1 mm Hg
0.01 in Hg
0.1 mbar
0.001 psi
0.0001 atm
0.01 kPa
Atmospheric Pressure Accuracy ±3mm Hg within ±15°C from the temperature during calibration
Atmospheric Pressure Calibration automatic at one custom point
Temperature Range -5.00 to 55.00°C
Temperature Resolution 0.01°C
Temperature Accuracy ±0.15°C
Temperature Calibration Automatic at one custom point
Additional Specifications
Maximum probe immersion Depth - 20 metres
Temperature compensation automatic from -5 to 55°C
Logging Memory 45,000 records (continuous logging or log-on demand of all parameters)
Logging Interval one second to three hours
PC Connectivity via USB (with Hanna PC software)
Environment 0 to 50°C
RH 100% IP67
Battery Type/Life 1.5V AA batteries (4)/approximately 360 hours of continuous use without backlight (50 hours with backlight)
Dimensions/Weight 185 x 93 x 35.2 mm/400g
Document Downloads
Hanna Instruments HI-98194 Multiparameter Waterproof Meter User Manual Manual/Guide
Additional Information
SKU
HI-98194
Manufacturer Part Code
HI-98194

Customer Reviews

 
Hanna Instruments HI-98194 Multiparameter Waterproof Meter
£1,925.50
£2,310.60 inc vat
£1,925.50
£2,310.60 inc vat