Important Notice
This item is made-to-order exclusively for you once your order is placed. As a result, it is not eligible for cancellation or return under our standard policy. Your statutory rights remain unaffected.
The GMI 106223 uses highly advanced laser technology designed to detect natural gas with the aim of enhancing safety and improving detection for fire services, first responders, and utility markets.
General | |
---|---|
Weight | 3 lbs (approx.) |
Carry Case Dimensions | 21” x 17.5” x 9.5” |
Display | 3.5” colour LCD |
Storage | Internal SD card (not removable) |
Power | |
Battery | Removable Rechargeable Lithium-ion pack, 10.8 VDC 2.6Ah |
Battery Run Time | 8 hours at 32°F (approx.) |
Battery Charger | External 110-240 VAC, 50/60 Hz Universal |
Charge Time | 2-3 hours full charge (approx.) |
Charging Indicator | Integrated into a Dual Battery Charger |
Detection/Measurement System | |
Detection Method | Tunable Diode Laser Absorption Spectroscopy (TDLAS) |
Detection Distance | 100 ft (30m) nominal - may vary due to background type and conditions |
Measurement Range | 0 to 50K PPM-M |
Sensitivity | 5 PPM-M at distances from 0 to 100 ft (30m) |
Beam Size | Conical in shape with a 22” diameter at 100 ft (55cm at 30m) |
Lasers | |
IR Laser | Class I |
Spotter Laser | On-time duration is 2 minutes Class 2(II)<2mW @532nm Spot Size is 7mm at 15M |
Eye Safety Warning | Do not stare into the beam or view directly with an optical instrument |
Display | |
Resolution | 320x240 |
Camera | |
Aperture | f/2.6 |
FOV | 94DEG (at6.0mm image circle) |
GPS | |
Compatible with | GPS / GLONASS / Beidou / Galileo |
Communication | Bluetooth 4.2 BLE (to support future features and mobile applications) Wi-Fi USB Dual Mode |
Alarms | |
Digital Methane Detection (DMD) | Audible tone and visible colour border when detection threshold exceeded |
Adjustable Detection Alarm Level | 50' - 1 to 200 PPM-M 100' - 1 to 400 PPM-M |
System Fault & Warnings | Audible alarm and visual indication on the display |
Testing | |
Built-In Self-Test | Verifies operation and adjusts laser wavelength for maximum sensitivity |
Test Gas Cell | Integrated within the carrying case |
Data Logging | |
Saves to Internal Memory | FAULT logs Self-Test logs Captures |
Data Collected | Includes but not limited to: CH4 PPM-M measurement GPS location Timestamp Battery level Battery voltage Serial number of the instrument |
Operating Conditions | |
Operating Temperature | 0° to +122°F (-17° to 50°C) |
Humidity | 5 to 95% RH, non-condensing |
Regulatory | |
Instrument Protection | IP54 (water splash and dust resistant) |
Compliance | EMC (EN61000-6-2, EN6100-6-4) |
Radio Equipment Directive | (2014/53/EU) ETSI EN 301 489-1 v2.2.0 |
EN 61326-1:2013 | |
47 CFR Part 15 & ICES-003 |