Reading temperature levels in a wide variety of applications doesn't have to be difficult - with the Fluke 62 MAX infrared thermometer, you can get quick, accurate and reliable measurements of surface temperatures without the need to make direct contact.
You can use the Fluke 62 MAX infrared thermometer anywhere; these units are made tough with dust and water resistance as well as ultra-durable casing which can withstand a drop from a height of up to 3m. There's a reason why this thermometer's tagline is 'Handle Without Care' - take a look at the video below to see how useful and durable this infrared (IR) thermometer really is.
Making a measurement with the Fluke 62 MAX is simple - just use the built-in precision laser point to determine your measurement point and the thermometer will quickly determine surface temperature with a high degree of accuracy.
There's many benefits to using the Fluke 62 MAX for your temperature measurements, including:
Reliable temperature measurements go hand-in-hand with HVAC work; thankfully, Fluke's 62 MAX thermometer delivers the accuracy and reliability you need.
This infrared thermometer is suitable for many different HVAC applications, including:
Why not also consider upgrading to Fluke's 62 MAX+ model instead?
It may look the same as the standard 62 MAX, but the Plus model has even higher accuracy, wider temperature range and a number of other benefits.
This table shows the difference between each.
Function | Fluke 62 MAX | Fluke 62 MAX+ |
---|---|---|
Temperature Range | -30 to 500°C (-22 to 932°F) | -30 to 650°C (-22 to 1202°F) |
Accuracy | ± 1.5 °C or ± 1.5 % of reading ± 2.0 at -10 °C to 0 °C ± 3.0 at -30 °C to -10 °C |
± 1°C or ± 1.0 % of reading ± 2.0 at -10 °C to 0 °C ± 3.0 at -30 °C to -10 °C |
Response Time | <500 ms (95 % of reading) Spectral Response: 8 to 14 microns Emissivity: 0.10 to 1.00 |
<300 ms (95 % of reading) Spectral Response: 8 to 14 microns Emissivity: 0.10 to 1.00 |
Optical Resolution | 10:1 (calculated at 90 % energy) | 12:1 (calculated at 90 % energy) |
Display Resolution | 0.1 °C (0.2 °F) | 0.1 °C (0.2 °F) |
Repeatability of Readings | ± 0.8 % of reading or <± 1.0 °C (2 °F), whichever is greater |
± 0.5 % of reading or <± 0.5 °C (1 °F), whichever is greater |
Power | AA Battery | AA Battery |
Laser Pointer | Single laser | Dual lasers |
Temperature Range | -30 °C to 500 °C (-22 °F to 932 °F) |
Accuracy | ±1.5 °C or ±1.5% of reading, whichever is greater -10 °C to 0 °C: ±2.0 -30 °C to -10 °C: ±3.0 |
Response Time (95%) | <500 ms (95% of reading) |
Optical Resolution | 10:1 (calculated at 90% energy) |
Display Resolution | 0.1 °C (0.2 °F) |
Repeatability of Readings | ±0.8% of reading or <±1.0 °C (2 °F), whichever is greater |
Power | AA battery |
Battery Life | 10 hours with laser and backlight on |
Weight | 255 g (8.99 oz) |
Size | (175 x 85 x 75) mm (6.88 x 3.34 x 2.95) inches |
Operating Temperature | 0 °C to 50 °C (32 °F to 122 °F |
Storage Temperature | -20 °C to 60 °C (-4 °F to 140 °F), (without battery) |
Operating Humidity | 10 % to 90 % RH non-condensing at 30 °C (86 °F) |
Operating Altitude | 2000 meters above mean sea level |
Storage Altitude | 12,000 meters above mean sea level |
IP Rating | IP 54 per IEC 60529 |
Drop Test | 3m |
Vibration Shock | IEC 68-2-6 2.5 g, 10 to 200 Hz, IEC 68-2-27, 50 g, 11 m |
EMC | EN 61326-1:2006 EN 61326-2:2006 |
Compliance | EN/IEC 61010-1: 2001 |
Laser Safety | FDA and EN 60825-1 Class II |