Fluke TiS75+ Thermal Imaging Camera
The Fluke TiS75+ Thermal Imaging Camera is a handheld infrared-imaging camera with a resolution of 384px x 288px, a 40mk thermal sensitivity, and a -50°C to +550°C temperature range with a ±2°C/2% accuracy. It is also equipped with a 42° x 30° field-of-view, a minimum focus distance of 0.5m, and supports both manual and fixed focus.
Furthermore, it includes an array of imaging and annotation functions. It has 6 colour palettes, colour alarms, measurement tools, and a Picture-in-Picture mode.
Dew Point Colour Alarm
The Fluke TiS75+ also features a Dew Point Colour Alarm. It functions by calculating the Dew Point and subsequently displaying everything within the FOV that is at the dew point temperature or below as a thermal image, and everything in the FOV that is above the dew point temperature as a digital image. This allows the user to see where condensation is forming and asses where objects are on the dew point scale.
In addition to this, thermographers can use the camera’s voice annotations feature to add voice notes (up to 60s) to every thermal image. This means users can identify and record faults in real time. Moreover, individuals can save time identifying images by using the IR-PhotoNotes function to capture photos of asset numbers or other identifiers. These images serve as a reference when looking at thermal pictures on a computer.
Asset Tagging
Similarly, as the Fluke TiS75+ is Fluke Connect enabled, it supports asset taggin
g. Users need only scan an asset’s QR code and the TiS75+ will automatically save corresponding images to the asset’s dedicated folder. This results in greater overall efficiency as thermographers do not need to spend time sorting images.
The Fluke TiS75+ Thermal Imaging Camera is a water- and dust-resistant (IP54), handheld, infrared-imaging camera. It has been drop-tested from 2m and is equipped with a 3.5” VGA touchscreen display. It is ideal for efficient, proactive maintenance and allows users to capture thermal images with the relevant information embedded in the picture.
Optional Frame Rates
There are two versions of this thermal camera: one with a 9Hz frame rate and one with a 27Hz frame rate. Please see the table below for further information.
SKU | Frame Rate |
5160037 | 9Hz |
5160043 | 27Hz |
Videos
Key Features
- A handheld, infrared-imaging camera with a Dew Point Colour Alarm
- Two models available: 9Hz and 27Hz
- IR resolution: 384px x 288px
- Thermal sensitivity: 40mk
- Temperature range: -50°C to +550°C
- Accuracy: ±2°C/2%
- FOV: 42° x 30°
- Minimum focus distance: 0.5m
- Manual and fixed focus
- 6 colour palettes
- Colour alarms
- Measurement tools
- Picture-in-Picture mode
- Dew Point Colour Alarm: calculates the dew point and displays everything at or below this temperature as a thermal image, and everything above it as a digital image
- Voice annotations: record voice notes of up to 60s
- IR-PhotoNotes: capture images of asset numbers or identifiers
- Fluke Connect enabled
- Asset tagging: automatically sorts images into the relevant asset’s folder; simply scan the asset’s QR code
- Water- and dust-resistant (IP54)
- Drop-tested from 2m
- 3.5” VGA touchscreen display
- Ideal for efficient, proactive maintenance
- Capture thermal images with the relevant information embedded in the picture
What’s Included?
- Your Choice of Fluke TiS75+ Thermal Imaging Camera
- AC Power Supply
- 2x Lithium-ion Smart Batteries
- Two-bay Smart Battery Charger
- USB Cable
- 4GB microSD card
- Hard Carry Case
- Soft Transport Bag
- Adjustable Hand Strap
The Desktop Software and User Manual are available as a free download from Fluke.
Fluke TiS Thermal Camera Comparison Table
Model | Fluke TiS20+MAX | Fluke TiS55+ | Fluke TiS60+ | Fluke TiS75+ |
---|---|---|---|---|
Infrared Resolution | 120 x 90px | 256 x 192px | 320 x 240px | 384 x 288px |
IFOV | 7.6 mRad | 1.91 mRad | 1.86 mRad | 1.91 mRad |
Field of View | 50° x 38° | 28° x 20° | 34.1° x 25.6° | 42° x 30° |
Min Focus Distance | 0.5m | 0.46m | 0.15m manual focus 0.5m focus marker | |
Sensitivity | 60mK | 40mK | 45mK | 40mK |
Focus System | Fixed focus | Manual focus | Fixed focus | Manual focus |
Temperature Range | -20 °C to +400 °C | -20 °C to +550 °C | -20 °C to 400 °C | -20 °C to +550 °C |
Asset Tagging | - | Automatically organize and file thermal images by scanning QR codes | - | Automatically organize and file thermal images by scanning QR codes |
Voice Annotation | - | 60 second maximum audio recording via Bluetooth Audio Headset Profile (HSP) connection to external device. (sold separately) | ||
VIR-PhotoNotes | - | 1 | 3 | 3 |
Dew Point Calculation | - | - | - | Yes |
Video recording | - | - | - | Yes |
Remote operation | - | - | - | Yes |
User-definable spot markers | Hot and cold spot markers | 3 user-adjustable spot markers for a single pixel each | 5 user-adjustable spot markers for a single pixel each | |
User defined measurement boxes | - | 3 user-adjustable rectangles | User defined measurement boxes, Expandable-contractible measurement box | 5 user-adjustable rectangles |
Fluke TiS55+ & TiS75+ Thermal Imaging Camera Specifications
Model | TiS75+ | TiS55+ |
Infrared resolution | 384 x 288 (110,592 pixels) | 256 x 192 (49,152 pixels) |
IFOV | 1.91 mRad | 1.91 mRad |
Field of view | 42° x 30° | 28° x 20° |
Minimum focus distance | 0.5 m | 0.5 m |
Focus system | Manual focus and 1 meter focus marker | Manual focus and 1 meter focus marker |
Wireless connectivity | Yes, to PC, iPhone® and iPad® (iOS 4s and later), Android™ 4.3 and up, and WiFi and LAN (where available) |
Yes, to PC, iPhone® and iPad® (iOS 4s and later), Android™ 4.3 and up, and WiFi and LAN (where available) |
Fluke Connect app compatible | Yes*, connect your camera to your smartphone, and images taken automatically upload to the Fluke Connect app for saving and sharing | Yes*, connect your camera to your smartphone, and images taken automatically upload to the Fluke Connect app for saving and sharing |
Fluke Connect Assets optional software | Yes*, assign images to assets and create work orders. Easily compare measurement types —whether mechanical, electrical or infrared images—in one location |
Yes*, assign images to assets and create work orders. Easily compare measurement types —whether mechanical, electrical or infrared images—in one location |
Asset Tagging | Scan a QR code to automatically organize and file thermal images with Fluke Connect™ | Scan a QR code to automatically organize and file thermal images with Fluke Connect™ |
IR-Fusion technology | AutoBlend continuous 0 % to 100 %. Adds the context of the visible details to your infrared image | AutoBlend continuous 0 % to 100 %. Adds the context of the visible details to your infrared image |
Picture-In-Picture (PIP) | Yes | Yes |
Display | 3.5" (8.9 cm landscape) touchscreen 640 x 480 LCD |
3.5" (8.9 cm landscape) touchscreen 640 x 480 LCD |
Ergonomic design | Designed for one-handed use | Designed for one-handed use |
Thermal sensitivity | 40 mk | 40 mk |
Level and span | Smooth auto and manual scaling | Smooth auto and manual scaling |
Fast auto-rescale in manual mode | Yes | Yes |
Minimum span (in manual mode) | 3° °C (4.5 °F) | 3° °C (4.5 °F) |
Minimum span (in auto mode) | 5°C (9.0 °F) | 5°C (9.0 °F) |
Built-in digital camera (visible light) | Up to 5mp | Up to 5mp |
Frame rate | 9 Hz or 27 Hz models | 9 Hz or 27 Hz models |
Dew point calculation | Yes, on camera | No |
Data Storage and Image Capture | ||
Internal memory | ~500 images | ~500 images |
External memory | ≥4 GB SD card (>1000 images) | ≥4 GB SD card (>1000 images) |
Image capture, review, save mechanism |
One-handed image capture, review, and save capability |
One-handed image capture, review, and save capability |
Image file formats | Non-radiometric BMP or JPEG or fully-radiometric is2 |
Non-radiometric BMP or JPEG or fully-radiometric is2 |
Memory review | Yes | Yes |
Software | Fluke Connect software—full analysis and reporting software with access to the Fluke Connect | Fluke Connect software—full analysis and reporting software with access to the Fluke Connect |
Analyze and store radiometric data on a PC | Yes | Yes |
Export file formats with Fluke Connect Software | is3, is2, BMP, GIF, JPEG, PNG, TIFF | is2, BMP, GIF, JPEG, PNG, TIFF |
Voice annotation | Yes, 60 second maximum audio recording via Bluetooth Audio Headset Profile (HSP) connection to external device. | Yes, 60 second maximum audio recording via Bluetooth Audio Headset Profile (HSP) connection to external device. |
IR-PhotoNotes | Yes. Up to 3 extra user-selectable visible light image capture to be included in IS2 file. | Yes. Up to 1 extra user-selectable visible light image capture to be included in IS2 file. |
Text annotations | After IS2 capture, user can type in a note using on-screen keyboard. | After IS2 capture, user can type in a note using on-screen keyboard. |
Video recording and formats | Standard and radiometric video. Up to 5 minutes recording length. avi and is3 | No |
Remote control operations | Yes | No |
Auto capture (temperature and interval) | Yes. User-selectable time interval for capturing IS2 or Jpeg files. | Yes. User-selectable time interval for capturing IS2 or Jpeg files. |
Battery | ||
Batteries (field-replaceable, rechargeable) |
Lithium-ion rechargeable battery | Lithium-ion rechargeable battery |
Battery life | ≥ 3.5 hours continuous without WiFi (Actual life depends on settings and usage) |
≥ 3.5 hours continuous without WiFi (Actual life depends on settings and usage) |
Battery charging time | ≤2.5 hours to full charge | ≤2.5 hours to full charge |
Battery charging system | Ti SBC3B Two-Bay Battery Charger or in-Imager charging. |
Ti SBC3B Two-Bay Battery Charger or in-Imager charging. (does not come with two-bay battery charger) |
AC operation | AC operation with included power supply, universal adapters included Output: 15 VDC, 2 A |
AC operation with included power supply, universal adapters included Output: 15 VDC, 2 A |
Power saving | User-selectable sleep and power off | User-selectable sleep and power off |
Temperature Measurement | ||
Temperature range (not calibrated below -10 °C) |
-20 °C to 550 °C (not calibrated below -10 °C) | -20 °C to 550 °C (not calibrated below -10 °C) |
Accuracy | ±2 °C or 2 % (whichever is greater) at 25 °C ambient temperature | ±2 °C or 2 % (whichever is greater) at 25 °C ambient temperature |
On-screen emissivity correction | Yes, “top ten” material list plus numerical adjustment between 0.01 and 1.00 |
Yes, “top ten” material list plus numerical adjustment between 0.01 and 1.00 |
On-screen reflected background temperature compensation |
Yes | Yes |
On-screen transmission correction | Yes | Yes |
Colour Palettes | ||
Standard palettes | 6 | 6 |
General Specifications | ||
Colour alarms | Yes. User-selectable hot and cold point and internal/external range color alarms. Modifies palettization of IR image by limiting which pixels are drawn using palette colors based on the pixel temperature. |
Yes. User-selectable hot and cold point and internal/external range color alarms. Modifies palettization of IR image by limiting which pixels are drawn using palette colors based on the pixel temperature. |
Infrared spectral band | ~8-14μm | ~8-14μm |
Operating temperature | -10 °C to 50 °C (14 °F to 122 °F) | -10 °C to 50 °C (14 °F to 122 °F) |
Storage temperature | -20 °C to 50 °C (-4 °F to 122 °F) without batteries |
-20 °C to 50 °C (-4 °F to 122 °F) without batteries |
Relative humidity | 10 % to 95 % non-condensing | 10 % to 95 % non-condensing |
Spot temperature | Center spot (unmovable) | Center spot (unmovable) |
User-definable spot markers | Yes, 5 user-adjustable spot markers for a single pixel each. Position is adjustable. Temperature value for marker shown on screen. User can choose to switch display on/off for each marker. |
Yes, 3 user-adjustable spot markers for a single pixel each. Position is adjustable. Temperature value for marker shown on screen. User can choose to switch display on/off for each marker. |
User-defined measurement boxes | Yes, 5 user-adjustable rectangles. Size and position are adjustable. Rectangle statistics shown on screen: Min, Max, Average temperature. User can choose to switch display on/off for each marker. |
Yes, 3 user-adjustable rectangles. Size and position are adjustable. Rectangle statistics shown on screen: Min, Max, Average temperature. User can choose to switch display on/off for each marker. |
Hard case | Rugged hard carrying case with soft transport bag, including adjustable strap | Rugged hard carrying case with soft transport bag, including adjustable strap |
Safety standards | IEC 61010-1: Pollution Degree 2 | IEC 61010-1: Pollution Degree 2 |
Electromagnetic compatibility | IEC 61326-1: Portable Electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class A |
IEC 61326-1: Portable Electromagnetic Environment; IEC 61326-2-2 CISPR 11: Group 1, Class A |
Australian RCM | RCM IEC 61326-1 | RCM IEC 61326-1 |
US FCC | 47 CFR 15 Subpart C Sections 15.207, 15.209, 15.249 |
47 CFR 15 Subpart C Sections 15.207, 15.209, 15.249 |
Vibration | 10 Hz to 150 Hz, 0.15 mm, IEC 60068-2-6 | 10 Hz to 150 Hz, 0.15 mm, IEC 60068-2-6 |
Shock | 30 g, 11 ms, IEC 60068-2-27 | 30 g, 11 ms, IEC 60068-2-27 |
Drop | Engineered to withstand 2 m drop | Engineered to withstand 2 m drop |
Sized (H x W x L) | ~ (26.7 cm x 10.1 cm x 14.5 cm) ~ (10.5 in x 4.0 in x 5.7 in) |
~ (26.7 cm x 10.1 cm x 14.5 cm) ~ (10.5 in x 4.0 in x 5.7 in) |
Weight (battery included) | ≤2.27 kg (5 lb) | ≤2.27 kg (5 lb) |
Enclosure rating | IP54 | IP54 |
Warranty | Two-years (standard) | Two-years (standard) |
Recommended calibration cycle | Two-years (assumes normal operation and normal aging) |
Two-years (assumes normal operation and normal aging) |
Supported languages | Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish |
Czech, Dutch, English, Finnish, French, German, Hungarian, Italian, Japanese, Korean, Polish, Portuguese, Russian, Simplified Chinese, Spanish, Swedish, Traditional Chinese, and Turkish |
RoHS compliant | Yes | Yes |
Reviews