Fluke P3012-P Gas Deadweight Tester – With Pump

SKU
FLK-P3012-P
Rating:
0%
(0)
Reward Points
:
10707
£10,707.60 £8,923.00
Free UK Delivery*
Advice & Support Call 01642 931329 or contact us
Price Match We won't be beaten, let us know
 Fluke P3012-P Gas Deadweight Tester – With Pump

The Fluke P3012-P Gas Deadweight Tester – With Pump can be used to calibrate pressure sensing instruments, such as transducers, transmitters, gauges or pressure switches. There are three models available in this range. These models vary with regards to their pressure ranges and measurement units; for further information please see the table below.

Product Code Product Name  Pressure Range
P3012-KPA-P Fluke P3012-KPA-P Gas Deadweight Tester 100kPA with Pump 1.5 to 100kPa
P3012-MBAR-P Fluke P3012-MBAR-P Gas Deadweight Tester 1000 mbar with Pump 15 to 1000 mbar
P3012-INH2O-P Fluke P3012-INHH2O-P Gas Deadweight Tester 400 inH2O with Pump 5 to 400 inH2O

The inclusion of a hand pump allows the user to generate pressure up to 300psi (20 bar), however, an external gas source may also be connected to the tester via the /NPT female external supply port. The Fluke P3012-P Gas Deadweight Tester includes a high-quality needle valve allowing the user to make fine pressure adjustments.

The Fluke P3012-P Gas Deadweight Tester is only able to produce pressure; however, other Fluke dual pressure and vacuum models are available. The pressure generated within the tester causes the piston and cylinder assembly to rise. The user balances this upward force by adding accurately calibrated weight masses on to the piston. The total pressure is determined by adding the total value of the weight masses to the piston weight and carrier assembly.

The piston/ cylinder assembly includes a floatation indicator and is manufactured to the highest standards, with traceable accuracies to international standard laboratories, such as the National Institute of Standards and Technology (NIST).  It is optimised to provide stability and durability, as well as limit the effects of distortion and thermal coefficients.  

Moreover, each model is supplied with an ISO 17025 accredited calibration certificate and is calibrated to standard gravity (980.665 cm/s²). This gives the Fluke P3012-P Gas Deadweight Tester an accuracy of 0.015% of the reading. This accuracy can be improved to 0.008% as the Fluke P3012-P can be calibrated to local gravity in order to account for the effect of this force on the weight masses.  

In addition to a calibration certificate, the Fluke P3012-P Gas Deadweight Tester is also supplied with spare seals and 1/8, 1/4, 3/8, 1/2 NPT and BSP adapters as well as M20 and M14 metric adapters. The instrument itself includes a detachable lid allowing the user to transport the Fluke P3012-P Gas Deadweight Tester safely and easily. 

The inclusion of a selection of adapters, along with the Fluke P3012-P Gas Deadweight Tester’s test station design with O-rings, adds to the practicality and convenience of this instrument, as the user does not require PTFE tape or wrenches to connect additional modules to the tester. Furthermore, its mounted spirit level and adjustable feet improves the ease with which this calibrator may be set up and ensures that it can be used within a variety of environments without compromising its accuracy.

Finally, any weight masses supplied with this tester are constructed from series 3 non-magnetic austenitic stainless steel and are marked with both the instrument’s serial number and the nominal pressure value relative to the pressure piston. These masses are supplied in a robust weight box with a secure locking mechanism, again ensuring that they can be safely and easily transported between worksites.

The Fluke P3012-P Gas Deadweight Testers – With Pump are accurate, practical instruments ideal for calibrating a variety of pressure sensing instruments.

Fluke P3012-P Gas Deadweight Tester – With Pump Key Features

  • Calibrate pressure sensing instruments such as transducers, transmitters, gauges and pressure switches
  • Three models available with various pressure ranges and measuring units
  • The hand pump can be used to generate pressure up to 300psi (20 bar)
  • Attach an external gas source via the /NPT female external supply port
  • High-quality needle valve for fine pressure adjustments
  • Weight masses are added on to the piston to balance the upward force caused by pressure
  • The total pressure is determined by adding the total value of the weight masses to the piston weight and carrier assembly
  • Piston/ cylinder assembly includes a floatation indicator
  • Piston/ cylinder is manufactured to the highest standards with traceable accuracies to international standard laboratories (NIST)
  • Piston/ cylinder is optimised to provide stability and durability
  • Piston/cylinder is optimised to limit the effects of distortion and thermal coefficients
  • Supplied with an ISO 17025 accredited calibration certificate
  • Calibrated to standard gravity (980.665 cm/s²)
  • Option to calibrate the tester to local gravity
  • Standard accuracy of 0.015% of the reading
  • Standard accuracy can be improved to 0.008%
  • Supplied with spare seals
  • 1/8, 1/4, 3/8, 1/2 NPT and BSP adapters are provided
  • M20 and M14 metric adapters included
  • Detachable lid allows the user to transport the tester safely and easily
  • Test station design
  • O-rings remove the need for wrenches or PTFE tape when connecting additional instruments
  • Mounted spirit level
  • Adjustable feet
  • Weight masses are constructed from series 3 non-magnetic austenitic stainless steel
  • Weight masses are stored in a robust weight box with a secure locking mechanism
  • Accurate, practical instruments ideal for calibrating pressure measuring equipment

What’s Included?

  • Your choice of Fluke P3012-P Gas Deadweight Tester – With Pump
  • Weight Masses
  • Removable Lid
  • ISO 17025 Accredited Calibration Certificate
  • Spare Seals
  • 1/8, 1/4, 3/8, 1/2 NPT and BSP Adapters
  • M20 and M14 Metric Adapters

Fluke P3012-P Gas Deadweight Tester – With Pump Technical Specifications

Accuracy 
Accuracy ±0.015% of reading (±0.008% optional)

*Accuracy based on % of reading from 10% to 100% of the piston range when used in accordance with the corrections found on the calibration certificate. Below 10% ± (accuracy class) x 10% of the piston range.

Mass and PCU Materials of Construction 
Standard weight material Series 3 non-magnetic austenitic stainless steel
Weight density 7.8 g/cm³
Optional fractional weights Solution heat treated aluminium
Weight density 2.7 g/cm³
Piston Material Ceramic
Cylinder Material Martensitic steel
Coefficient of Expansion 11 ppm/°C
General 
Test port adaptors 1/8, 1/4, 3/8 and ½ NPT or BSP
Instrument weight 24 lbs
Instrument size 17.5 W x 12 D x 8.5 H
Mass set weight (typical) 65 lbs
Minimum Standard weight Increments 1 inH2O, (5 mbar)
Built-in Pressure Hand Pump Max pressure 300 psi (20 bar)
Fluke P3000 Series Deadweight Pressure Tester - Datasheet Datasheets Fluke Deadweight Pressure Tester Selection Guide Manuals & Guides