The device integrates with Versiv / LinkWare or mobile phones via the Fi-In app. With automated pass/fail analysis available in seconds, the compact, ergonomic design and autofocus functionality make inspections efficient and comfortable. The compact, ergonomic design with autofocus ensures fast and effortless testing, even when inspecting hundreds of cables or ports.
Call 01642 931 329 or complete the form:
Spend £150+ (Ex VAT) on any qualified Fluke or Beha-Amprobe product(s) and claim a free tool of your choice from the list at Fluke Promotion. Valid February 17 2025 - July 31 2025.
Claims are made direct to Fluke. Terms and conditions apply.
Temperature Range | Operating: -10 °C to +45 °C (+14 °F to +113 °F) Storage: -10 °C to +60 °C (+14 °F to +140 °F) |
---|---|
Humidity Range | Operating: 0 % to 95 % (32 °F to 95 °F, 0 °C to 35 °C) RH non-condensing Storage: 0 % to 95 % (95 °F to 113 °F, 35 °C to 45 °C) RH non-condensing |
Altitude | Operating: 4,000 m (3,200 m with AC adapter) Storage: 12,000 m |
Vibration | 2 g, 5 Hz to 500 Hz |
Shock | 1 metre drop test |
Safety | IEC 61010-1: Pollution Degree 2 |
EMC | IEC 61326 1: Controlled Electromagnetic Environment; IEC 61326-2-1 CISPR 11: Group 2, Class A USA (FCC): 47 CFR 15 Intentional Radiators: This device complies with part 15 of the FCC Rules. |
Endtype Support | Single Fiber and MPO: 1x8 (8 fibers), 1x12 (8, 10, or 12 fibers), 1x16 (16 fibers), 2x12 (16, 20, or 24 fibers), 2x16 (32 fibers) |
Test Limits | IEC 61300-3-35 ED. 2 MM IEC 61300-3-35 ED. 2 SM APC IEC 61300-3-35 ED. 3 MM IEC 61300-3-35 ED. 3 SM APC Document Only |
Optional automated Pass/Fail Test Time | Less than 2 seconds per fibre |
Camera Type | 5 Megapixel 1/4-inch CMOS sensor |
Field of View | FOV MPO View All - 4800 x 2000 µm FOV Single Fiber - 985x1310 µm |
Resolution | 1 µm |
Light Source | LED, >100,000 hr life |
Endface Illumination | Coaxial blue LED |
Port Illumination | White LED |
Battery Type | Lithium-ion; 10.8-hour life |
Power Adapter | Input: 100 to 240 VAC ±10%, 50/60Hz Output: 15 VDC, 2 A maximum Class II |
Wireless Transmission* | Output power: <100 mW Frequency ranges: 2.4 GHz (2412 MHz to 2462 MHz) |
Dimensions | 6.625 in x 5.375 in x 2.125 in (168 mm x 137 mm x 54 mm) (with no dust cap or adapter tip) Length with dust cap: 7.5 in (191 mm) |
Weight | 11.5 oz (326 gm) (with dust cap and no adapter tip) |
* For more information, go to www.flukenetworks.com/manuals and search for “Radio Frequency Data for Class A” |