Fluke Networks DSX Cable Analyser

The Fluke Networks DSX Cable Analyser facilitates copper and fibre cable testing and certification to industry standards. There are two versions of the Fluke Networks DSX Cable Analyser available:

  • Fluke Networks DSX-5000 Cable Analyser suitable for testing up to 10 Gig Ethernet in Cat 5e, Cat 6, Cat 6A or Class FA cabling systems
  • Fluke Networks DSX-8000 Cable Analyser suitable for testing up to 40 Gig Ethernet in Cat 8 cabling systems.

Fluke Networks DSX Cable Analyser Comparison

DSX-5000 Cable Analyser  DSX-8000 Cable Analyser
Cat 6A / Class EA test time 10 seconds 8 seconds
Cat 8 / Class I/II test time - 16 seconds
HDTDX/HDTDR diagnostic test times ≈ 3 seconds ≈ 3 seconds
Internal memory ≈ 12,000 Cat 6A with plots ≈ 5,000 Cat 8 with plots; ≈ 12,000 Cat 6A with plots
>Level V Accuracy (1 GHz)

Level VI/2G Accuracy (2 GHz) -

Resistance Unbalance measurement

Shield integrity check and distance to fault

TCL measurement

ELTCTL measurement

CDNEXT measurement

CMRL measurement

Built-in Alien XTalk capability

Channel Adapter 1 GHz Range 2 GHz Range
Permanent Link Adapter 1 GHz Range 2 GHz Range

Fluke Networks DSX Cable Analyser Tests

Designed to exceed the IEC Level V specification with less than half the allowable crosstalk margin, the Fluke Networks DSX Cable Analysers deliver reliable, accurate results across the full frequency range. They can complete full Cat 6A or Class FA standards tests in under ten seconds and can verify two cables at two wavelengths in both directions using the copper or fibre module.

Additionally, the Fluke Networks DSX Cable Analyser supports balance measurements such as Transverse Conversion Loss (TCL) and Equal Level Transverse Conversion Transfer Loss (ELTCTL). Providing a fast method of project completion and system acceptance, the Fluke Networks DSX Cable Analyser offer a PASS/FAIL result and allow you to review individual test parameters by numerically or graphically. They also support a complete suite of Resistance Unbalance standards needed for Power over Ethernet.

Fluke Networks DSX Cable Analyser Diagnostics

Moreover, unlike other testers, the Fluke Networks DSX Cable Analysers’ diagnostic capabilities have no frequency limitation. A dedicated diagnostics button runs all troubleshooting tests and saves the data. Results are also displayed graphically, allowing you to look down the cable and pinpoint crosstalk, return loss, or shield faults on any given link. The Fluke Networks DSX Cable Analysers can store up to 12 000 test results with full graphics.

Furthermore, a patented AC measurement technique makes the Fluke Networks DSX Cable Analysers the only testers capable of reporting the distance to shield integrity issues. This is particularly advantageous when checking datacentres as other testers will either miss issues or indicate a break in a shield but be unable to indicate the location. The Fluke Networks DSX Cable Analysers can do both.

Fluke Networks DSX Cable Analysers are Easy to Use

Equipped with a new ProjX management system, the Fluke Networks DSX Cable Analysers minimise set-up errors or data loss because:

  • All job-specific details are saved under a simple name
  • Provides test results by cable ID
  • Merges changes without duplicates
  • Defaults to the last copper or fibre module installed

In addition to this, the ProjX management system provides a real-time 0-100% job completion scale; offers the operator the option to isolate tests requiring additional investigation; and includes a “Fix Later” function which generates an automatic list of corrections, helping to ensure reliable, accurate testing. The ProjX management system makes it easy to switch between projects, track progress, and collate results.

A Taptive user interface also adds to the Fluke Networks DSX Cable Analysers' ease of use. This high-quality, touchscreen ensures all jobs are accessible from the menu screen. Simply touch the test and a large display will confirm which checks need to be performed. To ensure correct configuration the Fluke Networks DSX Cable Analysers provide simplified diagrams and animated instructions to help you set up the mesurements.

Fluke Networks LinkWare Management Software

Create reports and upgrade the Fluke Networks DSX Cable Analysers’ software using Fluke Networks’ LinkWare Management Software. Logos may be uploaded to reports. The Fluke Networks LinkWare Software also includes a new statistical report function. This option creates charts and diagrams from test results allowing you to assess your cabling plant performance and infrastructure, as well as spot anomalies.

Furthermore, using the Fluke Networks LinkWare Management Software, project managers can manage workflow and consolidate test results.

The Fluke Networks DSX Cable Analysers are industry-leading, efficient, easy-to-use copper and fibre cable testers.

Fluke Networks DSX Cable Analyser Key Features

  • Analyser for copper and fibre cable testing and certification to industry standards
  • Fluke Networks DSX-5000 Cable Analyser suitable for testing up to 10 Gig Ethernet in Cat 5e, Cat 6, Cat 6A or Class FA cabling systems
  • Fluke Networks DSX-8000 Cable Analyser suitable for testing up to 40 Gig Ethernet in Cat 8 cabling systems.
  • Exceed IEC V specification
  • Less than half the allowable crosstalk margin
  • Reliable, accurate results across the full frequency range
  • Complete full Cat 6A or Class FA standard tests in less than 10 seconds
  • Verify two fibres at two wavelengths in both directions using the copper module
  • Transverse Conversion Loss (TCL)
  • Equal Level Transverse Conversion Transfer Loss (ELTCTL)
  • Fast method of project completion and system acceptance
  • PASS/FAIL result
  • Review individual test parameters by value or graph
  • Supports Resistance Unbalance standards needed for Power over Ethernet
  • No frequency limit on diagnostic capabilities
  • Diagnostics button runs all troubleshooting tests and saves the data
  • Results are displayed graphically
  • Pinpoint crosstalk, return loss, or shield faults
  • Store up to 12 000 test results with full graphics
  • Patented AC measurement technique
  • Reports the distance to shield integrity issues
  • Perfect for checking datacentres
  • ProjX management system minimises set-up errors and data loss
  • All job-specific details are saved under a simple name
  • Provides test results by cable ID
  • Merges changes without duplicates
  • Defaults to the last copper or fibre module installed
  • Real-time 0-100% job completion scale
  • Option to isolate tests
  • Fix Later function
  • Taptive, touchscreen user interface
  • All jobs are accessible via the menu screen
  • Simplified diagrams and animated instructions for setting up tests
  • Create reports and upgrade the testers’ software using Fluke Networks LinkWare Management Software
  • Logos can be uploaded to reports
  • Statistical report function
  • Mange workflow and collate test results using the Fluke Networks LinkWare Management Software
  • Industry-leading, efficient, easy-to-use copper and fibre cable testers

What’s Included?

  • Fluke Networks DSX-5000 OR DSX-8000 Cable Analyser
  • Remote Unit

Fluke Networks DSX Cable Analyser Technical Specifications 

Cable Types 
Shielded and unshielded pair LAN cabling TIA Cat 3, 4, 5, 5e, 6, 6A, 8: 100 Ω ISO/IEC Class C, D, E, EA, F, FA and I/II: 100 Ω and 120 Ω
Standard Link Interface Adapters 
Permanent link adapters Plug type: shielded RJ45
Optional Plug type: Tera (for DSX-5000 only, DSX-8000 version available summer 2017)
Channel Adapters Jack type: shielded RJ45
Optional Jack type: Tera, GG45 (for DSX-5000 only, DSX-8000 version available summer 2017)
Test Standards 
TIA Cat 3, 4, 5, 5e, 6, 6A, 8 per TIA 568 Series
ISO/IEC Class C, D, E, EA, F, FA, I/II certification per ISO/IEC 11801 Series
Maximum frequency DSX-8000: 2000 MHz; DSX-5000 1000 MHz
General Specifications 
Autotest Time DSX-8000: Full 2-way Autotest of Cat 5e or 6/Class D or E: 7 seconds Full 2-way Autotest of Cat 6A/Class EA: 8 seconds Full 2-way Autotest of Cat 8: 16 seconds
DSX-5000: Full 2-way Autotest of Cat 5e or 6/Class D or E: 9 seconds Full 2-way Autotest of Cat 6A/Class EA: 10 seconds
Support test parameters (The selected test standard determines the test parameters and the frequency range of the tests) Wire Map, Length, Propagation Delay, Delay Skew, DC Loop Resistance, Insertion Loss (Attenuation), Return Loss (RL), NEXT, Attenuation-tocrosstalk Ratio (ACR-N), ACR-F (ELFEXT), Power Sum ACR-F (ELFEXT), Power Sum NEXT, Power Sum ACR-N, Power Sum Alien Near End Xtalk (PS ANEXT), Power Sum Alien Attenuation Xtalk Ratio Far End (PS AACR-F)
Input protection Protected against continuous telco voltages and 100 mA over-current. Occasional ISDN over-voltages will not cause damage
Display 5.7 in LCD display with a projected capacitance touchscreen
Case High impact plastic with show absorbing overmould
Dimensions Main Versiv unit with DSX module and battery installed: 2.625 in x 5.25 in x 11.0 in (6.67 cm x 13.33 cm x 27.94 cm)
Weight Main Versiv unit with DSX module and battery installed: 3 lbs, 5oz (1.28 kg)
Main unit and remote Lithium ion battery pack, 7.2 V
Typical battery life 8 hours
Charge time* Tester off: 4 hours to charge from 10 % capacity to 90 % capacity
Languages supported English, French, German, Italian, Japanese, Portuguese, Spanish, Chinese, Korean, Russian, Trad Chinese, Czech, Polish, Swedish, Hungarian
Calibration Service center calibration period is 1 year
Environmental Specifications 
Operating Temperature 32° F to 113° F (0° C to 45° C)
Storage Temperature -22° F to +140° F (-30° C to +60° C)
Operating relative humidity (% RH without
condensation)
0% to 90%, 32° F to 95° F (0° C to 35° C)
0% to 70%, 95° F to 113° F (35° C to 45 °C)
Vibration Random, 2 g, 5 Hz-500 Hz
Shock 1 m drop test with and without module and adapter
Safety CSA 22.2 No. 61010, IEC 61010-1 3rd Edition
Operating altitude 13,123 ft (4,000 m)
10,500 ft (3,200 m) with ac adapter
EMC EN 61326-1