Fluke ii905 Acoustic Imager
The Fluke ii905 Acoustic Imager is an ultrasonic-imaging camera optimised for detecting and assessing compressed air, gas, steam, and vacuum leaks in compressed air systems, pipelines, and industrial equipment. The ii905 is the mid-range model in Fluke’s range of ii-Series Acoustic Cameras. Like its sister product the Fluke ii500, the ii905 features advanced leak detection technology that isolates leak sound frequencies and filters background noise. Consequently, the ii905 can be used during factory/business uptime, thereby reducing expensive downtime usually required for routine maintenance. Moreover, like ii500, the ii905 will create and overlay a SoundMap™ onto the corresponding digital image, allowing maintenance technicians to pinpoint leaks easily, efficiently, and effortlessly. The ii905 also builds on the capabilities of the ii500. It will calculate and display the leak size, leak rate, and estimated leak cost, as well as indicate the leak’s severity using a 1-10 LeakQ™ scale. This enables maintenance teams to make informed decisions when prioritising repairs. SoundMap™ digital images and additional data are indicated on the ii905’s large, seven-inch LCD, allowing professionals to see faults clearly. Videos and images may be tagged, annotated and saved to folders in the Fluke ii905 Acoustic Imager’s integrated memory. They may also be shared with team members and repair personnel using the ii905’s Reporting Tool and Wi-Fi connectivity.
Acoustic Imaging
The Fluke ii905 Acoustic Camera expands the ii500’s frequency and detection ranges. It can detect leaks between 2 and 65kHz from a distance of 70m. Automatic filtering of background noise means the Fluke ii905 can be used to conduct routine maintenance inspections during ongoing operations. This negates the need for expensive downtime, allowing businesses to maximise uptime and, therefore, productivity and profitability.
SoundMap™ Technology
An acoustic array of miniature microphones and a dedicated algorithm capture and convert ultrasonics sounds emitted by compressed, air, gas, steam, and vacuum leaks into a SoundMap™. Depending on the frequency range selected, the SoundMap™ will automatically adapt to filter out background noise. The SoundMap™ is superimposed onto a corresponding colour visual image captured by the ii905’s integrated 5MP digital camera. This allows maintenance teams to see and locate leaks clearly and in real-time.
LeakQ™ Assessment
In addition to visually representing acoustic leaks, the ii905 includes a distance-estimation algorithm that it uses to calculate leak size, rate, and estimated cost. Furthermore, like the ii500, the ii905 will indicate the severity of the leak using a LeakQ™ index. This makes assessing leak severity and prioritising repairs simple.
User-friendly Design
The Fluke ii905 Acoustic Imager is built to be easy to use and requires minimal training to operate. It offers capacitive touchscreen operation and a seven-inch 1280 x 800px LCD screen. The Fluke ii905 makes scanning large areas, compressed air systems, and industrial equipment quick and simple.
Videos and images may be tagged to assets and locations as well as annotated with notes. They are saved to folders in the ii905’s 32GB memory and can be shared with relevant persons using the Report Tool and Wi-Fi interface.
Transform Leak Detection with the Fluke ii905 in 4 Easy Steps
- Locate: Quickly and easily scan areas to pinpoint sources of leaks
- Document: Capture screenshots that can be tagged and annotated
- Share: Send screenshots to your team to determine a maintenance schedule
- Repair: investigate the problem further during planned downtime and/or fix it
The Fluke ii905 Acoustic Imager is an easy-to-use, efficient ultrasonic camera perfect for effortlessly detecting and quantifying compressed air, gas, steam, and vacuum leaks.
Key Features
- Ultrasonic-imaging camera for detecting and assessing compressed air, gas, steam, and vaccum leaks
- Scan air systems, pipelines, and industrial equipment for leaks
- Mid-range model in Fluke’s ii-Series of Acoustic Cameras
- Advanced leak detection technology: isolates leak sound frequencies and filters background noise
- Conduct routine maintenance inspections during uptime
- SoundMap™ technology: converts ultrasonic sound into a SoundMap™ that is overlaid onto a digital image
- Pinpoint leaks clearly, precisely, and quickly
- 5MP digital camera
- Frequency range: 2-65kHz
- Detection distance: up to 70m
- LeakQ™ Assessment: calculates the size, rate, and estimated cost of the leak and assigns a severity index (scale: 1-10)
- Easy to use
- Minimal training required
- Capacitive touchscreen
- 7” 1280 x 800px LCD
- 32GB memory
- Report Tool
- Wi-Fi interface
- Tag images and footage
- Annotate images and footage
- Save images and footage to folders
- Share images and footage with relevant persons
- Easy-to-use, efficient ultrasonic camera perfect for detecting and quantifying air, gas, steam, and vacuum leaks
What’s Included?
- Fluke ii905 Acoustic Imager
- AC Power Supply
- Lithium-Ion Smart Battery Pack
- USB Cable
- Adjustable Hand and Neck Strap
- Sensor Array Protection Cover
- Hard Carrying Case
Fluke ii905 Acoustic Imager Technical Specifications
Sensors | |
Frequency band | 2 kHz to 65 kHz |
Detection range1 | 0.5 to > 70 meters (1.6 to > 230 feet) |
Field of view (FOV) | 63°± 5° |
Nominal frame rate | 25 FPS |
Built-in digital camera (visible light) | |
Field of view (FOV) | 63°± 5° |
Focus | Fixed lens |
Zoom | 3 x digital zoom |
Resolution | 5.0 MP |
Display | |
Size | 7" LCD with backlight, sunlight readable |
Resolution | 1280 x 800 (1,024,000 pixels) |
Touchscreen | Capacitive |
Acoustic image | SoundMapTM image |
Image storage | |
Storage capacity | 32 GB (> 8,000 pictures / > 1,600 videos) |
Image format | Blended visual and SoundMapTM .JPG or .PNG |
Video format | Blended visual and SoundMapTM .MP4 |
Video length | Up to 5 minutes |
Digital export | USB-C for data transfer |
Acoustic measurements | |
Measurement range (typical) | 15.4 to 115.2 dB SPL (± 1 dB SPL 2 kHz) 5.6 to 102.5 dB SPL (± 2 dB SPL 19 kHz) 28.4 to 131.1 dB SPL (± 1 dB SPL 35 kHz) 41.8 to 133.1 dB SPL (± 3 dB SPL 52 kHz) |
Classification and quantification | |
LeakQTM | Leak size scale, Leak rate, and Leak cost estimation |
PDQ ModeTM | - |
MecQTM | - |
Auto max/min dB gain | Auto or manual, user-selectable |
Frequency band selection | User selectable through user-made presets or manual entry |
Battery | |
Battery | Rechargeable and field replaceable Li-ion battery |
Battery life | 6 hours |
Battery charging time | 4 hours |
Battery charging system | Internal (USB-C) |
Software | |
Ease of use | Intuitive user interface |
Acoustics: Show dB scale | On/Off |
Acoustics: Min/Max dB | Manual/Auto |
Acoustics: Profiles | Preset capture profiles |
Acoustics: High frequency | - |
Acoustics: Multiple sources | Show single or multiple sources |
Palette: Colors | 3: Grayscale, Ironbow, and Blue-Red |
Palette: Overly transparency | Yes: 1-100 % |
Grayscale mode | Yes |
Centerpoint markers | On/Off |
Trend graphs | Frequency and dB scale |
Spotmarkers | dB level reading at center point of image |
Leak values | Leak costs, Leak volume, LeakQTM scale (1-10) |
Master admin menu | Yes |
Annotation | Asset name; Asset ID; Asset type; Leak type; Gas type; Pressure |
Photo notes | Up to 4 photos notes for reference |
Asset inspection status | 'As left', 'As found', 'Undetermined' |
Asset ID | Text input and automatic QR code based asset ID identification |
Actions annotation | Action requirements, Action priority level, Action notes |
Other | Operating conditions, Weather notes |
General specifications | |
Tripod holder / connector | Yes: 1/4"-20 |
USB | 2 x USB-C |
Wireless | Wi-Fi |
Operating Temperature | -10 to 45 °C (14 to 113 °F) |
Storage Temperature | -20 to 70 °C (-4 to 158 °F) without batteries installed |
Relative humidity | 10 to 95 % non-condensing |
Size (H x W x L) | 186 mm x 322 mm x 68 mm (7.3 inches x 12.7 inches x 2.7 inches) |
Weight (battery included) | 2.0 kg (4.4 pounds) |
Ingress Protection (IP) | IP40 |
Warranty | 2 year |
Fluke Premium Care | Premium Care Standard2 |
Self-diagnostic notification | Array-health test to identify when microphone array needs attention |
Supported languages | Dutch, English, Finish, French, German, Italian, Japanese, Korean, Polish, Portuguese, Simplified Chinese, Spanish, Swedish, Traditional Chinese |
RoHS compliant | Yes |
Safety |
|
General safety | IEC 61010-1: Pollution degree 2 |
Electromagnetic Compatibility (EMC) International | IEC 61326-1: Industry Electromagnetic Environment, CISPR 11: Group 1, Class A |
Korea (KCC) | Class A Equipment (Industrial Broadcasting and Communication) |
USA (FCC) | 47 CFR 15 subpart C |
Notes | ¹ Depending on ambient conditions |
² Subject to regional availability |
Reviews
SKU | FLK-II905 |
---|---|
Manufacturer Part Code | 5594650 |