This version of the Fluke i3000s comes with a long-length, 7" diameter flexible cable that is designed to be bent around difficult applications in order to test current levels.
The Fluke i3000s isn't a clamp meter, but is a clamp device that is designed to be used with other Fluke devices such as oscilloscopes, recorders, dataloggers and multimeters. Once attached to the meter and secured to a conductor point this device can be used to measure current across three ranges of 30A, 300A and 3000A with 1, 10 or 100mV/A output.
This product is CAT III 600V safety rated.
Specifications
- Current ranges 30 A, 300 A, 3000 A, AC rms
- Output sensitivity (AC-coupled) 100 mV, 10 mV, 1 mV per A
- Load impedance 100 kΩ minimum
- Accuracy at +25 °C ± 1 % of range (45 Hz to 65 Hz)
- Linearity 10 % to 100 % of range ± 0.2 % of reading
- Noise 8 mV ac rms (30 A), 2 mV ac rms (300 A, 3000 A)
- Frequency range 10 Hz to 50 kHz (-3 dB)
- Phase error < ± 1 º (45 Hz to 65 Hz), ± 10 º (at 20 kHz)
- Position sensitivity with cable > 25 mm from the coupling ± 2 % of range
- External field with cable > 200 mm from the head ± 1 % of range
- Power supply 2 x AA/MN 1500/LR6 Alkaline, , 400 hours, low battery indicator or dedicated external power supply
- Temperature Coefficient ± 0.08% of reading per °C
- Working voltage see Safety standards section 600 V AC rms or DC
- Head Circumference 610 mm (24 in)
- Head cable diameter 14.3 mm (0.56 in)
- Head bend radius 38.1 mm (1.5 in)
- Cable length (head to electronics) 2 m (6.56 ft)
- Output connection 0.5 m cable terminated with safety BNC connector. Supplied with 4mm safety plug adapter
- Operating temperature range -20 °C to +90 °C (-4 °F to 190 °F) (head) -20 °C to +85 °C (-4 °F to 185 °F) (electronics)
- Storage temperature range -40 °C to +105 °C (-40 °F to 221 °F) (head) -20 °C to +85 °C (-4 °F to 185 °F) (electronics)
- Operating humidity 15 % to 85 % (non-condensing)
- Weight 180 g (0.396 lb) (head) 190 g (0.419 lb) (electronics)
- Safety standards BS EN 61010-1: 2001 BS EN 61010-2-032: 2002 BS EN 61010-031: 2002 600 Vrms, Category III, Pollution Degree 2 Use of the probe on uninsulated conductors is limited to 600 V AC rms or dc and frequencies below 1 kHz.
- EMC standards EN 61326: 1998 +A1, A2, & A3
- Maximum conductor size 610 mm or 914 mm, depending on model
Reviews
SKU | i3000s flex-36 |
---|---|
Manufacturer Part Code | 2584901 |
Model Ref | i3000s flex-36 |