Fluke FEV300 EV Charging Test Adapter imitates an electric vehicle to stimulate a charging cycle (activates voltage/current output). It can be used with Fluke’s 1664FC Multifunction Installation Tester or oscilloscopes, such as the 120B Series, to check the safety and functionality of EV charging stations according to IEC/EN 61851-1 and IEC/HD 60364-7-222.
There are three versions of the Fluke FEV300 EV Charging Test Adapter available: one without plugs; one with a type-2 plug; and one with a type-1 plug and a type-2 plug. Please see the table below for further details.
FLK-FEV300/BASIC | FLK-FEV300/TY2 | FLK-FEV300/TY1T2 | |
---|---|---|---|
Fluke FEV300 EV Charging Test Adapter | ✔ | ✔ | ✔ |
Fluke Type-1 Plug (FEV300-CON-TY1) | ✖ | ✖ | ✔ |
Fluke Type-2 Plug (FEV300-CON-TY2) | ✖ | ✔ | ✔ |
Soft Carrying Bag | ✔ | ✔ | ✔ |
When used with a compatible multifunction tester or oscilloscope, the Fluke FEV300 EV Charging Test Adapter can conduct the following tests/simulations:
In addition to this, the Fluke FEV300 EV Charging Test Adapter includes terminals for CP signal output, allowing you to check the communication between the adapter (imitating an electric vehicle) and the charging station. Furthermore, L1, L2, L3, N, and PE measuring terminals enable connections to Fluke measurement instruments facilitating further safety and functional tests.
The IP54-rated Fluke FEV300 EV Charging Test Adapter is an adaptable, reliable, and practical instrument for verifying the safety and functionality of electric vehicle charging stations.
General Features | |
Input voltage | Up to 250 V (single phase system) / up to 480 V (three phase system), 50/60 Hz, max 10 A |
Internal power consumption | 3 W max |
FEV300-CON-TY2 Plug | AC charging mode 3, suitable to IEC 62196-2 type 2 socket outlet or fixed cable with vehicle connector (type 2, 7P three-phase) |
FEV300-CON-TY1 Plug | AC charging mode 3, suitable to IEC 62196-2 type 1 or SAE J1772 with vehicle connector (type 1, 5P single-phase) |
Dimensions (H × W × D) | 110 × 45 × 220 mm length without connection cable and test cable |
Weight (including type 1 or type 2 connection cable) |
Approx. 1 kg |
Safety standards | IEC/EN 61010-1, pollution degree 2 IEC/EN 61010-2-030, CAT II 300 V, protection class II |
Ingress protection | IEC 60529: IP54 (housing) IEC 60529: IP54 (measuring terminals with protection caps in place, connector/ plug in connected condition or with protection caps in place, otherwise IP20) |
Operating temperature | -20 °C to 40 °C |
Storage temperature | -20 °C to 50 °C |
Operating humidity range | 10 % to 85 % relative humidity non-condensing |
Storage relative humidity | 0 % to 85 % non-condensing |
Operating altitude | 2000 m max. |
Functions | |
PE Pre-Test | Visible indication >50 V AC/DC between PE conductor and touch sensor |
PP Simulation | Open, 13 A, 20 A, 32 A, 63 A |
CP States | State A, B, C, D |
CP Error state “E” | On/off (CP signal short-circuited to PE) |
PE Error state "F" (Earth fault) | On/off (interruption of PE conductor) |
Outputs (for test purpose only) | |
Measuring terminals L1, L2, L3, N, PE | Max. 250/480 V, max. 10 A |
CP signal output terminals | Approx. +/-12 V |