Note: This Fluke IR window is available in two variations. Both are the same except model number CV301 comes with a security key for locking the window when not in use.
With Fluke IR windows, you can use your Fluke thermal camera to see what's happening inside electrical panels without the need to open them up!
Easy to install (takes on average just five minutes per window) and protected to the highest standards, Fluke IR windows seal directly into the electrical panel and will automatically ground themselves upon installation for extra protection. Each window comes with a unique code identifier for easy documentation and repair location.
The windows can be used both indoors and outdoors and are available either with or without a security key (model CV301 comes with a key).
Spend £150+ (Ex VAT) on any qualified Fluke or Beha-Amprobe product(s) and claim a free tool of your choice from the list at Fluke Promotion. Valid February 17 2025 - July 31 2025.
Claims are made direct to Fluke. For more information and terms and conditions, visit Fluke Promotion.
Model | CV400 | CV401 | CV300 | CV301 | CV200 | CV201 |
---|---|---|---|---|---|---|
Size | 95mm (4in) | 75mm (3in) | 50mm (2in) | |||
Voltage Range | Any | |||||
NEMA Environment Type | Type 4/12 (indoor/outdoor) | |||||
AutoGround | Yes | |||||
ClirVu Optic | Yes | |||||
Operating Temperature | -40 to 232°C (-40 to 450°F) and 260°C (500°F) intermittent |
|||||
Compatible with All Fluke Cameras | Yes | |||||
Jam Nut Locking System | Yes | |||||
Cover and Fastener Permanently Attached | Yes | |||||
Single-Hole Install | Yes | |||||
Hand Turn and Security Key Door Latch Options | Yes | |||||
Visual Inspection and Fusion Capable | Yes | |||||
Short/Mid/Long-Wave IR and UV Capable | Yes | |||||
Ratings and Testing | ||||||
Arc-Tested (IEEE C37.20.7) | 63kA for 30 cycles @ 60Hz at KEMA | |||||
UL 50V Component Recognition | Yes | |||||
UL 50/NEMA Environmental Rating | NEMA Type 4/12 | |||||
UL1558 | Yes | |||||
CSA C22.2 No. | Yes | |||||
CSA Type Rating | Type 4 | |||||
IP Rating | IP67 at TUV | |||||
Lloyds Register | Up to 11kV marine switchgear, indoor or outdoor (offshore only) | |||||
Vibration Rating | IEC60068-2-6 at TUV | |||||
Humidity Rating | IEC60068-2-3 at TUV | |||||
Installation | ||||||
Actual Mounting Hole Diameter Required | 115.42mm (4.544in) | 89.89mm (3.539in) | 61.37mm (2.416in) | |||
Greenle Punch Kit = Punch/Die | 742BB = 2984AV/2983AV | 739BB = 1431AV/1432AV | 7BB = 441AV/442AV | |||
Recommended Max Panel Thickness | 10 gage | |||||
Overall Window Height | 189.3mm (7.45in) | 141.5mm (5.57in) | 112.9mm (4.45in) | |||
Overall Window Width | 147.1mm (5.79in) | 111.5mm (4.39in) | 83.0mm (3.27in) | |||
Overall Window Thickness | 23.0mm (0.90in) | 16.2mm (0.64in) | 16.2mm (0.64in) | |||
Door Latch | Hand Turn | Security Key | Hand Turn | Security Key | Hand Turn | Security Key |
Optics | ||||||
Optics Insert Diameter | 95mm (3.74in) | 75mm (2.96in) | 50mm (1.97in) | |||
Viewing Aperture Diameter | 87.63mm (3.450in) | 67.95mm (2.675in) | 42.93mm (1.690in) | |||
Viewing Aperture Area | 6032 sq.mm (9.35 sq.in) | 3626 sq.mm (5.62 sq.in) | 1445 sq. mm (2.24 sq.in) | |||
Thickness | 4mm (0.16in) | 2mm (0.08in) |