Fluke 9172-X-256 Field Metrology Well – Choice of Insert

The Fluke 9172-X-256 Field Metrology Well – Choice of Insert is available in seven models with different disc inserts. For further information, please see the table below.

Product Code  Product Name 9172 Disc Insert Name Disc Insert Part Number  Hole Types
9172-A-256 Fluke 9172-A-256 Field Metrology Well A 9172-INSA Misc Holes
9172-B-256 Fluke 9172-B-256 Field Metrology Well B 9172-INSB Comparison Holes
9172-C-256 Fluke 9172-C-256 Field Metrology Well C 9172-INSC 0.25-inch Holes
9172-D-256 Fluke 9172-D-256 Field Metrology Well D 9172-INSD Metric Comparison Holes
9172-DW-256 Fluke 9172-DW-256 Field Metrology Well DW N/A **INDICATES THAT A DISC IS NOT INCLUDED**
9172-E-256 Fluke 9172-E-256 Field Metrology Well E 9172-INSE Metric Misc Holes with 0.25-inch Ref Hole
9172-F-256 Fluke 9172-F-256 Field Metrology Well F 9172-INSF Metric Comparison Misc Holes with 0.25-inch Ref Hole
For a visual indication of how these discs will appear, please see the attached datasheet listed under 'Technical Specifications'.

PLEASE NOTE that these instruments do NOT include integrated reference thermometry, therefore they cannot read external PRTs with ITS-90 coefficients. Versions of these instruments with integrated reference thermometry are available here.

The Fluke 9172-X-256 Field Metrology Well has a temperature range of 35°C to 425°C and can be used to calibrate an array of temperature sensing equipment such as thermometers, temperature probes and thermal switches. This temperature calibrator has been designed to provide the user with all the practicality and convenience of a dry-well calibrator but with the stability, uniformity and accuracy of bath temperature calibrators.

Dependent on temperatures, this instrument is able to offer a heat source with a stability of ±0.005°C to ±0.01°C. This is made possible as a result of the inclusion of Fluke’s patent-pending proprietary electronics and dual-zone control (analogue and digital). These features also help to maintain the instrument’s repeatability and display accuracy of ±0.2°C (at 425°C). Moreover, the Fluke 9172-X-256 Field Metrology Well is calibrated using accredited, traceable PRTs which, again, work to ensure and maintain the instrument’s accuracy. The precise calibration of this instrument also reduces the effects of hysteresis to 0.04°C.

In addition to this, the Fluke 9172-X-256 Field Metrology Well has been designed to keep loading effects and temperature gradients to a minimum. Again the inclusion of Fluke’s proprietary electronics and dual-zone control contribute to the reduction of these entities, as does the depth of the instrument’s well. At 203mm deep, the integrated well is able to provide the operator with a homogeneous temperature zone of 60mm (from the bottom of the well) with an axial/vertical uniformity of (up to) ± 0.05°C. The Fluke 9172-X-256 Field Metrology Well is also able to provide a radial uniformity of (up to) ±0.01°C.

The depth of the well also ensures that thermometers and probes may be properly immersed thereby reducing the possibility of stem conduction errors at high temperatures. Once more, this improves the accuracy of calibrations carried out using the Fluke 9172-X-256 Field Metrology Well.

The design, features and calibration of this instrument help to ensure that it fulfils the six critical components of performance (calibrated display accuracy, stability, axial uniformity, radial uniformity, loading effects and hysteresis) as detailed in the European Metrology Community’s EA-10/13 Document. The design of this instrument also adds to this instrument’s practicality and expands its scope-for-use. It is compact, lightweight and rugged making it suitable for use in a variety of industrial and/or hard-to-access environments.

It includes a large, LCD display which allows the user to view the block temperature, cut-out temperature, stability criteria and ramp rate quickly and easily. The numeric keypad, onscreen menus, and a function key for selecting between °C and °F facilitate the user’s ability to configure the instrument to suit the application. Moreover, this instrument includes four pre-programmed calibration tasks which can be tailored to the user’s needs via the entry of up to eight temperature set points with ‘ramp and soak’ times between each point.

In addition to this, the Fluke 9172-X-256 Field Metrology Well includes a Switch Test protocol for zeroing in on the ‘dead-band’ for thermal switches.

The instrument's RS-232 interface and the supplied Fluke Modell 9930 Interface-It Software provide the user with the option to view results and operate the Fluke 9172-X-256 Field Metrology Well remotely via his/her computer. The user is able to access and adjust the instrument’s features, functions and settings using this interface and software.

Alternatively, the Fluke 9172-X-256 Field Metrology Well may be used with Fluke’s MET / TEMP II Software (NOT included) to perform automated calibrations of RTDs, thermocouples and thermistors.

The Fluke 9172-X-256 Field Metrology Well – Choice of Insert is an adaptable, versatile and practical instrument ideal for calibrating a variety of temperature sensing instruments used in an array of industry sectors.

Fluke 9172-X-256 Field Metrology Well – Choice of Insert Key Features

  • Available in seven models with varying disc inserts
  • Does NOT include integrated reference thermometry
  • Temperature range: 35°C to 425°C
  • Can be used to calibrate an array of temperature sensing equipment including thermometers, temperature probes and thermal switches
  • Provides the practicality and convenience of a dry well calibrator
  • Offers the accuracy, stability and uniformity of a bath temperature calibrator
  • Stability: ±0.005°C to ±0.01°C (dependent on temperature)
  • Includes Fluke’s patent-pending proprietary electronics
  • Dual-zone control (digital and analogue)
  • Display accuracy of ±0.2°C (at 425°C) or better
  • Calibrated using accredited and traceable PRTs
  • Reduces the effects of hysteresis to 0.04°C
  • Well depth of 203mm
  • Provides a homogeneous temperature zone of 60mm
  • Axial uniformity: up to ±0.05°C (dependent on temperature)
  • Radial uniformity: ±0.01°C (dependent on temperature)
  • The depth of well reduces the possibility of stem conduction errors at high temperatures
  • Fulfils the six critical components of performance as outlined by the EA-10/13
  • Compact, lightweight and rugged
  • Large, LCD display
  • View block temperature, cut-out temperature, stability criteria and ramp rate via the display
  • Function key for selecting between °C and °F
  • Numeric keypad
  • Onscreen menus
  • Includes four pre-programmed calibration tasks
  • The user is able to enter eight setpoint temperatures and ‘ramp and soak’ times between these points
  • Switch Test protocol for zeroing in on the ‘dead-band’ for thermal switches
  • RS-232 interface
  • Supplied with Fluke’s Model  9930 Interface-it Software
  • Interface and software allow the user to view results and operate the instrument remotely
  • Can be used with Fluke’s MET/ TEMP II Software (NOT included)
  • Adaptable, versatile and practical instrument ideal for calibrating a variety of temperature sensing instruments

What’s Included?

  • Your Choice of Fluke 9172-X-256 Field Metrology Well – Choice of Insert
  • Fluke Model 9930 Interface-It Software

Fluke 9172-X-256 Field Metrology Well – Choice of Insert Technical Specifications

The Fluke 9172-X-256 Field Metrology Well – Choice of Insert is part of Fluke's series of 917X Metrology Wells. The technical specifications for the models in this series are detailed below. 

Specifications 9170 9171 9172 9173
Range
(at 23 °C ambient)
–45 °C to 140 °C
(–49 °F to 284 °F)
–30 °C to 155 °C
(–22 °F to 311 °F)
35 °C to 425 °C
(95 °F to 797 °F)
50 °C to 700 °C†
(122 °F to 1292 °F)
Display Accuracy ± 0.1 °C full range ± 0.1 °C: 35 °C to 100 °C
± 0.15 °C: 100 °C to 225 °C
± 0.2 °C: 225 °C to 425 °C
± 0.2 °C: 50 °C to 425 °C
± 0.25 °C: 425 °C to 660 °C
Stability ± 0.005 °C full range ± 0.005 °C: 35 °C to 100 °C
± 0.008 °C: 100 °C to 225 °C
± 0.01 °C: 225 °C to 425 °C
± 0.005 °C: 50 °C to 100 °C
± 0.01 °C: 100 °C to 425 °C
± 0.03 °C: 425 °C to 700 °C
Axial Uniformity
(60 mm)
 
± 0.1 °C at –45 °C
± 0.04 °C at –35 °C
± 0.02 °C at 0 °C
± 0.07 °C at 140 °C
± 0.025 °C at –30 °C
± 0.02 °C at 0 °C± 0.07 °C at 155 °C
 
± 0.05 °C: 35 °C to 100 °C
± 0.1 °C: 100 °C to 225 °C
± 0.2 °C: 225 °C to 425 °C
 
± 0.1 °C: 50 °C to 100 °C
± 0.25 °C: 100 °C to 425 °C± 0.4 °C: 425 °C to 700 °C
Radial Uniformity
 
± 0.01 °C full range ± 0.01 °C: 35 °C to 100 °C
± 0.02 °C: 100 °C to 225 °C
± 0.025 °C: 225 °C to 425 °C
± 0.01 °C: 50 °C to 100 °C
± 0.025 °C: 100 °C to 425 °C
± 0.04 °C: 425 °C to 700 °C
Loading Effect
(with a 6.35 mm
reference probe and
three 6.35 mm probes)
± 0.02 °C at –45 °C
± 0.005 °C at –35 °C
± 0.01 °C at 140 °C
± 0.005 °C at –30 °C
± 0.005 °C at 0 °C
± 0.01 °C at 155 °C
± 0.01 °C full range ± 0.02 °C at 425 °C
± 0.04 °C at 700 °C
Hysteresis 0.025 °C 0.04 °C 0.07 °C
Well Depth 160 mm (6.3 in) 203 mm (8 in)
Resolution 0.001 °C
Display LCD, °C or °F, user-selectable
Key Pad Ten key with decimal and +/- button. Function keys, menu key, and °C / °F key.
Cooling Time
 
44 min: 23 °C to –45 °C
19 min: 23 °C to –30 °C
19 min: 140 °C to 23 °C
30 min: 23 °C to –30 °C
25 min: 155 °C to 23 °C
220 min: 425 °C to 35 °C
100 min: 425 °C to 100 °C
235 min: 700 °C to 50 °C
153 min: 700 °C to 100 °C
 
Heating Time 32 min: 23 °C to 140 °C
45 min: –45 °C to 140 °C
44 min: 23 °C to 155 °C
56 min: –30 °C to 155 °C
27 min: 35 °C to 425 °C 46 min: 50 °C to 700 °C
Size (HxWxD) 366 x 203 x 323 mm (14.4 x 8 x 12.7 in)
Weight 14.2 kg (31.5 lb) 15 kg (33 lb) 13.2 kg (29 lb) 15 kg (33 lb)
Power 115 V ac (± 10 %), or
230 V ac (± 10 %), 50/60 Hz, 550 W
115 V ac (± 10 %), or
230 V ac (± 10 %), 50/60 Hz, 1025 W
Computer Interface RS-232 Interface with 9930 Interface-it control software included
Traceable Calibration
(NIST)
Data at –45 °C, 0 °C, 50 °C, 100 °C, and 140 °C Data at –30 °C, 0 °C, 50 °C, 100 °C, and 155 °C Data at 100 °C, 150 °C, 250 °C, 350 °C, and 425 °C Data at 100 °C, 200 °C, 350 °C, 500 °C, and 660 °C
†Calibrated to 660 °C; reference thermometer recommended at higher temperatures.
Fluke 917X Field Metrology Well – Datasheet Datasheets Fluke 917X Field Metrology Well – User Manual Manuals & Guides

Reviews

Additional Information
SKU Fluke 9172-X-256
Manufacturer Part Code 3016013

Made to Order item: This item is made-to-order with a lead time once the order is placed. Once an order is placed it cannot be cancelled or returned unless the unit is found to be faulty.