The Fluke 9142-X-P-256 Field Metrology Well with Process Electronics and Selectable Disc Insert is a more advanced version of the Fluke 9142-X-256 Field Metrology Well, also available through this website.
This lightweight, robust and portable field metrology well, ideal for use in industrial environments, is available in seven models which differ only in regards to their disc inserts. For further information regarding these inserts please see the table below.
Fluke 9142-X-P-256 Field Metrology Well with Process Electronics Model Name | 9142 Insert Name | Part Number | Hole Types |
9142-A-P-256 | A | 9142-INSA | Imperial Misc Holes |
9142-B-P-256 | B | 9142-INSB | Imperial Comparison Holes |
9142-C-P-256 | C | 9142-INSC | 0.25-inch Holes |
9142-D-P-256 | D | 9142-INSD | Metric Comparison Holes |
9142-DW-P-256 | DW | N/A | **INDICATES THAT A DISC IS NOT INCLUDED** |
9142-E-P-256 | E | 9142-INSE | Metric Misc Holes with 0.25-inch Hole |
9142-F-P-256 | F | 9142-INSF | Metric Comparison Misc Holes with 0.25-inch Hole |
For a visual indication of how these discs will appear, please see the attached datasheet listed under 'Technical Specifications'. |
There are several advantages to the process electronics version of Fluke 9142 Field Metrology Well:
Two-Channel Thermometer Readout
This facilitates the measurement of PRTs, RTDs, thermocouples and 4-20mA transmitters including a 24V loop supply to the power transmitter. This product accepts ITS-90 PRTs and contains reference PRTs with stored, individual calibration constants (located on the memory chip within the housing of the sensor) facilitating the user’s ability to use sensors interchangeably.
The second of the two-channel thermometer readout's channels can be customised to facilitate 2-, 3- or 4-wire RTDs, thermocouples, or 4-20mA transmitters. This feature ensures that it is practical, simple and easy to carry out comparison calibration in the field, without compromising on accuracy as the readout feature features an accuracy of between ±0.01°C and ±0.07°C depending upon the measured temperature.
Transmitter Loop Calibrations
The Fluke 9142-X-P-256 Field Metrology Well makes whole transmitter loop calibration (including the electronics and sensor) easy. This helps to reduce the 75% of transmitter errors caused by un-calibrated sensors. By placing the transmitter sensor in the well with the reference PRT and connecting the transmitter electronics to the front panel, the Fluke 9124-X-P-256 is able to both power and measure transmitter current, whilst simultaneously sourcing and measuring the resultant temperature in the filed metrology well. Through using this process the user is able to obtain as-found and as-left data.
On-Board Non-Volatile Memory
This feature allows the Fluke 9142-X-P-256 to function as a turnkey solution as it is able to document up to twenty tests. When recorded these tests can be assigned and alphanumeric name, and can be recorded with the following information: block temperature, reference temperature, UUT values, error, date and time. All of the recorded test information can be viewed on the field metrology well’s easy-to-read large LCD display or can be exported into a calibration report or ASCII file using the included Model 9930 Interface-It Software.
In addition to these extra features, the Fluke 9142-X-P-256, like the non-process electronics version does not compromise on EA criteria, such as accuracy, stability, axial (vertical) uniformity, well-to-well uniformity, loading and hysteresis, despite its compact size.
Similarly, it also has a range of -25°C to 150°C and takes only 15 minutes to cool to -25°C from 23°C and only 23 minutes to heat to 150°C from 23°C and features both auto and manual setup for automated thermostatic switch test procedure. The manual setup allows the user to customise ramp rate or add additional cycles, whilst the auto setup enables the quick running of a 3-cycle calibration procedure and provides the user with a final dead-band temperature. The auto-setup only requires the user to enter the nominal switch temperature.
Like the Fluke 9142-X-256 Field Metrology Well, the Fluke 9142-X-P-256 Field Metrology Well also has a full range display accuracy of ±0.2°C and new control technology which works to maintain performance even in extreme conditions, to that end this product also remains stable to ±0.01°C over its range. It is also supplied with IEC-17025 NVLAP accredited calibration certificate and features a stability indicator.
This product, like the non-process electronics version, is easy-to-use and includes pre-programmed calibration procedures which are easily accessible via the front panel, as are all the instrument’s inputs. Its function buttons and menu navigation buttons make the front panel easy to navigate, whilst its ‘SET PT’ button facilitates the fast and easy input of block temperature values.
Therefore the Fluke 9142-X-P-256 Field Metrology Well with Process Electronics and Selectable Disc is a comprehensive, practical, accurate and versatile alternative to dry well temperature calibrators.
Fluke 9142-X-P-256 Field Metrology Well with Process Electronics and Selectable Disc Insert Key Features
- Advanced version of the Fluke 9142-X-256 Field Metrology Well
- Available in seven models with different selectable discs
- Lightweight
- Robust
- Portable
- Ideal for use in industrial environments
- Two channel thermometer readout facilitates the measurement of PRTs, RTDs, thermocouples and 4-20mA transmitters including a 24V loop supply to the power transmitter
- Whole transmitter loop calibration is possible and easy, helps to reduce the 75% of transmitter errors caused by un-calibrated sensors.
- On-board volatile memory can store up to 20 tests along with an ID, the block temperature, reference temperature, UUT values, error, date and time
- Does not compromise EA criteria
- Temperature range: -25°C to 150°C
- 15 minutes to cool to -25°C from 23°C
- 23 minutes to heat to 150°C from 23°C
- Auto setup of automated thermostatic switch test procedure
- Manual setup of automated thermostatic switch test procedure
- Full range display accuracy of ±0.2°C
- New control technology maintains excellent performance even in extreme conditions
- Remains stable up to ±0.01°C over its range
- Supplied with IEC-17025 NVLAP accredited calibration certificate
- Stability indicator
- Large, easy-to-read LCD display
- Includes pre-programmed calibration procedures, easily accessible via front panel
- All inputs are easily accessible via front panel
- Function keys
- Menus navigation buttons
- ‘SET PT’ button facilitates the fast and easy input of block temperature values
What’s Included?
- Your choice of Fluke 9142-X-P-256 Field Metrology Well with Process Electronics and Selectable Disc Insert
- User Manual
- Technical Manual on CD
- Serial Cable
- Model 9930 Interface-It Software
- Report of Calibration
- Insert Removal Tool
- Test Leads
- 6-Pin DIN Connector for Reference Probe
Fluke 9142-X-P-256 Field Metrology Well with Process Electronics and Selectable Disc Insert Technical Specifications and Fluke 914X-X-P-256 Comparison Table
Technical Specifications | 9142 - X-P-256 | 9143-X-P-256 | 9144-X-P-256 |
Temperature Range at 23°C | –25 °C to 150 °C(–13 °F to 302 °F) | 33 °C to 350 °C(91 °F to 662 °F) | 50 °C to 660 °C (122°F to 1220 °F) |
Display Accuracy | ± 0.2 °C Full Range | ± 0.2 °C Full Range |
± 0.35 °C at 50 °C ± 0.35 °C at 420 °C ± 0.5 °C at 660 °C |
Stability | ± 0.01 °C Full Range |
± 0.02 °C at 33 °C ± 0.02 °C at 200 °C ± 0.03 °C at 350 °C
|
± 0.03 °C at 50 °C ± 0.04 °C at 420 °C ± 0.05 °C at 660 °C |
Axial Uniformity at 40 mm (1.6 in) | ± 0.05 °C Full Range |
± 0.04 °C at 33 °C ± 0.1 °C at 200 °C ± 0.2 °C at 350 °C |
± 0.05 °C at 50 °C ± 0.35 °C at 420 °C ± 0.5 °C at 660 °C |
Radial Uniformity | ± 0.01 °C Full Range |
± 0.01 °C at 33 °C ± 0.015 °C at 200 °C ± 0.02 °C at 350 °C |
± 0.02 °C at 50 °C ± 0.05 °C at 420 °C ± 0.10 °C at 660 °C |
Loading Effect (with a 6.35 mm reference probe and three 6.35 mm probes) | ± 0.006 °C Full Range | ± 0.015 °C Full Range |
± 0.015 °C at 50 °C ± 0.025 °C at 420 °C ± 0.035 °C at 660 °C
|
Hysteresis | 0.025 | 0.03 | 0.1 |
Operating Conditions | 0 °C to 50 °C, 0 % to 90 % RH (non-condensing) | ||
Environmental Conditions (for all specifications except temperature range) | 13 °C to 33 °C | ||
Immersion (Well) Depth | 150 mm (5.9 in) | ||
Insert OD | 30 mm (1.18 in) | 25.3 mm (1.00 in) | 24.4 mm (0.96 in) |
Heating Time |
16 min: 23 °C to 140 °C 23 min: 23 °C to 150 °C 25 min: –25 °C to 150 °C
|
5 min: 33 °C to 350 °C
|
15 min: 50 °C to 660 °C |
Cooling Time |
15 min: 23 °C to –25 °C 25 min: 150 °C to –23 °C |
32 min: 350 °C to 33 °C 14 min: 350 °C to 100 °C |
35 min: 660 °C to 50 °C 25 min: 660 °C to 100 °C
|
Resolution | 0.01 ° | ||
Display | LCD, °C or °F user-selectable | ||
Size (HxWxD) | 290 mm x 185 mm x 295 mm (11.4 x 7.3 x 11.6 in) | ||
Weight | 8.16 kg (18 lb) | 7.3 kg (16 lb) | 7.7 kg (17 lb) |
Power Requirements | 100 V to 115 V (± 10 %) 50/60 Hz, 635 W 230 V (± 10 %) 50/60 Hz, 575 W | 100 V to 115 V (± 10 %), 50/60 Hz, 1400 W 230 V (± 10 %), 50/60 Hz | 1800W |
Computer Interface | RS-232 and 9930 Interface-it control software included |
||
Process Electronics Specifications | |||
Built-in Reference Thermometer Readout Accuracy (4-Wire Reference Probe)† | ± 0.010 °C at -25 °C ± 0.015 °C at 0 °C ± 0.020 °C at 50 °C ± 0.025 °C at 150 °C ± 0.030 °C at 200 °C ± 0.040 °C at 350 °C ± 0.050 °C at 420 °C ± 0.070 °C at 660 °C |
||
Reference Resistance Range | 0 ohms to 400 ohms | ||
Reference Resistance Accuracy‡ | 0 ohms to 42 ohms: ±0.0025 ohms 42 ohms to 400 ohms: ±60 ppm of reading | ||
Reference Characterizations | ITS-90, CVD, IEC-751, Resistance | ||
Reference Measurement Capability | 4-wire | ||
Reference Probe Connection | 6-pin Din with Infocon Technology | ||
Built-in RTD Thermometer Readout Accuracy |
NI-120: ± 0.015 °C at 0 °C PT-100 (385): ± 0.02 °C at 0 °C PT-100 (3926): ± 0.02 °C at 0 °C PT-100 (JIS): ± 0.02 °C at 0 °C
|
||
RTD Resistance Range |
0 ohms to 400 ohms |
||
RTD Resistance Accuracy‡ |
0 ohms to 25 ohms: ±0.002 ohms 25 ohms to 400 ohms: ±80 ppm of reading |
||
RTD Characterizations |
PT-100 (385),(JIS),(3926), NI-120, Resistance |
||
RTD Measurement Capability |
4-wire RTD (2-,3-wire RTD w\ Jumpers only) |
||
RTD Connection |
4 terminal input |
||
Built-in TC Thermometer Readout Accuracy |
Type J: ± 0.7 °C at 660 °C |
||
TC Millivolt Range |
–10 mV to 75 mV |
||
Voltage Accuracy |
0.025% of reading + 0.01 mV |
||
Internal Cold Junction Compensation Accuracy |
± 0.35 °C (ambient of 13 °C to 33 °C) |
||
TC Connection |
Small connectors |
||
Built-in mA Readout Accuracy |
0.02 % of reading + 2 mV |
||
mA Range |
Cal 4-22 mA, Spec 4-24 mA |
||
mA Connection |
2 terminal input |
||
Loop Power Function | 24 V DC loop power | ||
Built-in Electronics Temperature Coefficient (0 °C to 13 °C, 33 °C to 50 °C) | ± 0.005 % of range per °C | ||
† The temperature range may be limited by the reference probe connected to the readout. The Built-In Reference Thermometer Readout Accuracy does not include the sensor probe accuracy. It does not include the probe uncertainty or probe characterization errors. | |||
‡ Measurement accuracy specifications apply within the operating range and assume 4-wires for PRTs. With 3-wire RTDs add 0.05 ohms to the measurement accuracy plus the maximum possible difference between the resistances of the lead wires. |