All Fluke Calibration Products

Fluke 9142-X-256 Field Metrology Well with Selectable Disc Insert

SKU
Fluke 9142-X-256
Rating:
0%
(0)
Reward Points
:
7447
£7,447.20 £6,206.00
Made to Order
Free UK Delivery*

Black Friday - Free Items With Orders Over £300

Black Friday Freebies
Spend £100 to £749.99
LED Head Torch (Worth: £15.99)

Spend Over £750
Free LED Head Torch & Extendable Flash Light (Worth: £35.98)

Prices Ex VAT
Advice & Support Call 01642 931329 or contact us
Price Match We won't be beaten, let us know
Fluke 9142-X-256 Field Metrology Well

The Fluke 9142-X-256 Field Metrology Well is rugged, efficient, accurate, portable and lightweight. It is able to calibrate an array of sensor types, and despite its compact size does not compromise on key EA requirements such as:

  • Accuracy
  • Stability
  • Axial (vertical) uniformity
  • Well-to-well uniformity
  • Loading
  • Hysteresis

This field metrology well is available in seven versions, as detailed in the drop-down selection. These versions differ only in their disc inserts. For further information concerning the above disc inserts please consult the table below.

Fluke 9142-X-256 Field Metrology Well Model Name 9142 Insert Name Part Number  Hole Types
9142-A-256 A 9142-INSA Imperial Misc Holes
9142-B-256 B 9142-INSB Imperial Comparison Holes
9142-C-256 C 9142-INSC 0.25-inch Holes
9142-D-256 D 9142-INSD Metric Comparison Holes
9142-DW-256 DW N/A **INDICATES THAT A DISC IS NOT INCLUDED**
9142-E-256 E 9142-INSE Metric Misc Holes with 0.25-inch Hole
9142-F-256 F 9142-INSF Metric Comparison Misc Holes with 0.25-inch hole
For a visual indication of how these discs will appear, please see the attached datasheet listed under 'Technical Specifications'.

**Please be aware that this version of the Fluke 9142 Field Metrology Well does not come with process electronics, however, models including process electronics are available here.

These top-of-the-range field metrology wells are highly accurate and are calibrated using high-quality, traceable, accredited PRTS. They are supplied with an IEC-1705 NVLAP  accredited calibration certificate, backed by thorough, reliable uncertainty analysis: this analysis takes into account temperature gradient, loading effect and hysterics.

The Fluke 9142-X-256 Field Metrology Well has a display accuracy of ±0.2°C and will remain stable to ±0.01°C beyond its full range. The Fluke 9142- X-256 has a range of –25 °C to150 °C and only takes 15 minutes to cool to the lowest temperature (from 23°C) and 23 minutes to reach the highest temperature (from 23ºC).

This product is also equipped with a stability indicator which will visually and audibly alert the user of the Fluke 9142-X-256 Field Metrology Well’s stability within the selected criteria.

Not only is this product optimised for efficiency, accuracy and durability, it is also designed to be as easy-to-use and convenient as possible. To this end it features two types of automated thermostatic switch test procedures:

  • Auto Setup: will run a three-cycle calibration procedure and provide a final result for the dead band temperature (indicated on  the LCD display), with only minimal data entry, i.e. the nominal switch temperature
  • Manual Setup: facilitates the user’s ability to customise and tailor the calibration procedure.

Both automated thermostatic switch test procedures enable swift and easy temperature tests.  In addition to this, the Fluke 9142-X-256 Field Metrology Well contains pre-programmed calibration routines which are easily accessible via the product’s memory. 

The Fluke 9142-X-256 Field Metrology Well is easy to navigate; it features function keys and menu navigation buttons which allow the user to access all the field metrology well's inputs.  Further to this, the front panel also includes a ‘SET PT’ button allowing the user to quickly set the block temperature, whilst the large LCD display allows for easy reading of results.

Finally, the Fluke 9142-X-256 Field Metrology Well is supplied with Model 9930 Interface-it Software which allows the user to export data into a calibration report or an ASCII file (raw data can also be viewed on the Fluke 9142-X-256’s screen).

The Fluke 9142-X-256 Field Metrology Well is a versatile, accurate, efficient and convenient product ideal for calibrating 4-20mA transmitters and simple thermostatic switches among other sensors.

 Fluke 9142-X-256 Field Metrology Well with Selectable Disc Insert Key Features

  • Field metrology well available in seven models with different disc inserts
  • Rugged, efficient, easy-to-use, accurate, lightweight and portable
  • Does not compromise on EA criteria
  • Calibrated using high-quality, traceable, accredited PTS
  • Supplied with IEC-1705 NVLAP accredited calibration certificate
  • Full range accuracy of ±0.2°C
  • Remains stable to ± 0.01°C beyond its range
  • Range of –25 °C to 150 °C
  • Takes 15 minutes to cool to its lowest temperature from 23ºC
  • Takes 23 minutes to heat to its highest temperature from 23ºC
  • Visual and audible stability indicator
  • Two types of automated thermostatic switch procedures: auto-setup and manual-setup
  • Contains pre-programmed calibration procedures stored in its memory
  • Function keys
  • Menu navigation buttons
  • Easily access all inputs via front panel
  • ‘SET PT’ button for entering block temperature
  • Large LCD display
  • Supplied with Model 9930 Interface-it Software facilitating the exportation of data
  • Ideal for calibrating 4-20mA transmitters, simple thermostatic switches and an array of sensors

What’s Included?

  • Your choice of Fluke 9142-X-256 Field Metrology Well with Selectable Disc Insert
  • User Manual
  • Technical Manual on CD
  • Serial Cable
  • Model 9930 Interface-it Software
  • Report of Calibration
  • Insert Removal Tool

Fluke 9142-X-256 Field Metrology Well with Selectable Disc Insert Technical Specifications and Fluke 914X-X-256 Comparison Table

Technical Specifications 9142 - X-256 9143-X-256 9144-X-256
Temperature Range at 23°C –25 °C to 150 °C(–13 °F to 302 °F) 33 °C to 350 °C(91 °F to 662 °F) 50 °C to 660 °C (122°F to 1220 °F)
Display Accuracy ± 0.2 °C Full Range ± 0.2 °C Full Range

± 0.35 °C at 50 °C 

± 0.35 °C at 420 °C 

± 0.5 °C at 660 °C

Stability  ± 0.01 °C Full Range

 

± 0.02 °C at 33 °C

± 0.02 °C at 200 °C

± 0.03 °C at 350 °C

 

 

± 0.03 °C at 50 °C

 ± 0.04 °C at 420 °C 

± 0.05 °C at 660 °C

Axial Uniformity at 40 mm (1.6 in) ± 0.05 °C Full Range

± 0.04 °C at 33 °C

± 0.1 °C at 200 °C

± 0.2 °C at 350 °C

± 0.05 °C at 50 °C

± 0.35 °C at 420 °C

± 0.5 °C at 660 °C

Radial Uniformity ± 0.01 °C Full Range

 

± 0.01 °C at 33 °C

± 0.015 °C at 200 °C

± 0.02 °C at 350 °C

± 0.02 °C at 50 °C 

± 0.05 °C at 420 °C 

± 0.10 °C at 660 °C

Loading Effect (with a 6.35 mm reference probe and three 6.35 mm probes) ± 0.006 °C Full Range ± 0.015 °C Full Range

 

± 0.015 °C at 50 °C

± 0.025 °C at 420 °C

± 0.035 °C at 660 °C

 

Hysteresis 0.025 0.03 0.1
Operating Conditions 0 °C to 50 °C, 0 % to 90 % RH (non-condensing)
Environmental Conditions (for all specifications except temperature range) 13 °C to 33 °C
Immersion (Well) Depth 150 mm (5.9 in)  
Insert OD 30 mm (1.18 in) 25.3 mm (1.00 in) 24.4 mm (0.96 in)
Heating Time

16 min: 23 °C to 140 °C

23 min: 23 °C to 150 °C

25 min: –25 °C to 150 °C

 

5 min: 33 °C to 350 °C

 

15 min: 50 °C to 660 °C

Cooling Time 

15 min: 23 °C to –25 °C

 25 min: 150 °C to –23 °C

32 min: 350 °C to 33 °C

14 min: 350 °C to 100 °C

35 min: 660 °C to 50 °C

25 min: 660 °C to 100 °C

 

Resolution 0.01 °
Display  LCD, °C or °F user-selectable
Size (HxWxD) 290 mm x 185 mm x 295 mm (11.4 x 7.3 x 11.6 in)
Weight 8.16 kg (18 lb) 7.3 kg (16 lb) 7.7 kg (17 lb)
Power Requirements 100 V to 115 V (± 10 %) 50/60 Hz, 635 W 230 V (± 10 %) 50/60 Hz, 575 W 100 V to 115 V (± 10 %), 50/60 Hz, 1400 W 230 V (± 10 %), 50/60 Hz  1800W
Computer Interface RS-232 and 9930 Interface-it control software included
Fluke 914X Field Metrology Well - Datasheet Datasheets Fluke 914X Field Metrology Well Series - User Manual Manuals & Guides

Reviews

Additional Information
SKU Fluke 9142-X-256
Manufacturer Part Code 3054314

Made to Order item: This item is made-to-order with a lead time once the order is placed. Once an order is placed it cannot be cancelled or returned unless the unit is found to be faulty.