Fluke 9140-X-256 Field Dry Well Temperature Calibrator –Choice of Disc

All Fluke Calibration Products
  • Compact, lightweight, practical calibrator optimised for versatility and efficiency
  • Temperature range: 35°C to 350°C
  • Available in five models with varying disc inserts
SKU
Fluke 9140-X-256
MPN
3015868

Read More

View All Dry Block / Metrology Well Calibrators

The Fluke 9140-X-256 Field Dry Well Temperature Calibrator – Choice of Disc can be used to calibrate temperature probes, as well as perform actuation testing via the checking of thermal switches. It has a temperature range of 35°C to 350°C and is available in five models with different interchangeable disc inserts. For further details, please see the table below.

Product Code Product Name  Disc Insert Name  Disc Insert Code  Wells in Disc Insert
9140-A-256 Fluke 9140-A-256 Field Dry Well Temperature Calibrator  A 3140-2 1/16" (1.6mm), 1/4" (6.35mm), 3/8in (9.5mm), 3/16" (4.8mm), 1/8" (3.2mm), 1/2" (12.7mm)
9140-B-256 Fluke 9140-B-256 Field Dry Well Temperature Calibrator  B 3140-3 3/16" (4.8mm), 1/4" (6.35mm), 3/8" (9.5mm), 3/16" (4.8mm), 1/4" (6.35mm), 3/8" (9.5mm)
9140-C-256 Fluke 9140-C-256 Field Dry Well Temperature Calibrator  C 3140-4 6x 1/4" (6.35mm)
9140-D-256 Fluke 9140-D-256 Field Dry Well Temperature Calibrator  D 3140-6 3mm, 4mm, 6mm, 3mm, 4mm, 6mm
9140-DW-256 Fluke 9140-DW-256 Field Dry Well Temperature Calibrator  DW NO INSERT NO INSERT

Each disc insert features a selection of variously sized wells optimised for holding probes of differing diameters. These inserts are interchangeable allowing the user to tailor the instrument to the application.

The Fluke 9140-X-256 Field Dry Well Temperature Calibrator has been designed so that when it is used with discs featuring larger diameter wells it has a uniformity of 0.4°C, and a uniformity of 0.1°C when used with discs featuring smaller diameter wells. Further to this, the Fluke 9140-X-256 has a minimum stability of ±0.05°C and is extremely efficient at reaching desired temperatures. For example, the Fluke 9140-X-256 Field Dry Well Temperature Calibrator can reach the following temperatures in the following times:

  • From ambient temperature (23°C) to 350°C takes twelve minutes
  • From 350°C to 100°C takes fifteen minutes

The heating and cooling rates can be adjusted via the front panel, adding to this product’s adaptability and ease-of-use. This unit is also supplied with an RS-232 interface which can be used with the provided Fluke Interface-It software to operate the Fluke calibrator from a PC. Together these accessories can be used to adjust set points and ramp rates, as well as conduct thermal switch tests whilst recording data, log dry-well readings and create electronic strip charts. Again these accessories and capabilities add to the versatility, adaptability and efficiency of the Fluke 9140-X-256.

Moreover, the Fluke 9140-X-256 Field Dry Well Temperature Calibrator is supplied with a NIST-traceable calibration. In addition to this, it is also easy to re-calibrate this tester in order to maintain its accuracy. The case need not be removed, making this process both more efficient and cost-effective.

The instrument is calibrated to an accuracy of ±0.5°C, allowing the operator to use the Fluke 9140-X-256 Field Dry Well Temperature Calibrator’s display as a reference. Alternatively, he/she can connect an external thermometer for use as a reference during calibration.

Finally, in terms of its physical design, this instrument has been optimised to be compact, lightweight and portable. Its ergonomic size and weight of only six-pounds make it easy to carry in one hand. The Fluke 9140-X-256 Field Dry Well Temperature Calibrator is therefore suitable for applications both within calibration laboratories and in the field.

The Fluke 9140-X-256 Field Dry Well Temperature Calibrator – Choice of Disc is a practical, easy-to-use, adaptable temperature calibrator optimised for speed and versatility.

Fluke 9140-X-256 Field Dry Well Temperature Calibrator – Choice of Disc Key Features

  • Calibrate temperature probes as well as perform actuation testing by checking thermal switches
  • Available in five models with various interchangeable disc inserts
  • Interchangeable disc inserts each include wells of varying sizes optimised for holding probes of differing diameters
  • Uniformity of 0.4°C when used with discs including larger well diameters
  • Uniformity of 0.1°C when used with discs featuring smaller well diameters
  • Minimum stability of ±0.05°C
  • From ambient temperature (23°C) to 350°C takes twelve minutes
  • From 350°C to 100°C takes fifteen minutes
  • Efficient at reaching desired temperatures
  • The RS-232 interface can be used with the Fluke Interface-it Software to operate the calibrator remotely from a computer
  • Using the RS-232 and aforementioned software the user can adjust set points and ramp rates, as well as conduct thermal switch tests whilst recording data, log dry-well readings and create electronic strip charts
  • NIST-traceable calibration
  • Easy to recalibrate
  • The case does not need to be removed in order to recalibrate the instrument saving the user time and money
  • Calibrated to an accuracy of ±0.5°C
  • The display can be used as a reference
  • Alternatively, an external thermometer can be connected to serve as a reference during calibration
  • Compact, lightweight and portable
  • Weight: 6 pounds
  • Easily carried in one hand
  • Suitable for applications in calibration laboratories and in the field
  • A practical, easy-to-use, adaptable temperature calibrator optimised for speed and versatility

What’s Included?

  • Your Choice of Fluke 9140-X-256 Field Dry Well Temperature Calibrator – Choice of Disc
  • NIST-traceable calibration
  • RS-232 Interface
  • Fluke’s Interface-It Software
£3,069.00
£3,682.80 inc vat
Free Delivery*
Important Notice
This item is made-to-order exclusively for you once your order is placed. As a result, it is not eligible for cancellation or return under our standard policy. Your statutory rights remain unaffected.
3069 Reward Points 60 Days Return

Ask An Expert
Price Match
Technical Information
Specification

Fluke 9140-X-256 Field Dry Well Temperature Calibrator –Choice of Disc Technical Specifications

The Fluke 9140-X-256 Field Dry Well Temperature Calibrator – Choice of Disc has a sister product, the Fluke 9103-X-256 Below Ambient Dry Well Calibrator – Choice of Insert; please find below the technical specifications for both models.

Specifications 9103 9140
Range  –25 °C to 140 °C
(–13 °F to 284 °F)
at 23 °C ambient 
35 °C to 350 °C
(95 °F to 662 °F) 
Accuracy  ± 0.25 °C (holes greater than 1/4" [6.35 mm]: ± 1 °C)  ± 0.5 °C (holes greater than 1/4" [6.35 mm]: ± 1 °C) 
Stability  ± 0.02 °C at –25 °C
± 0.04 °C at 140 °C 
± 0.03 °C at 50 °C
± 0.05 °C at 350 °C 
Well-to-Well Uniformity ± 0.1 °C between similarly sized wells ± 0.1 °C with similarly sized wells 
Heating Times  18 minutes from ambient to 140 °C  12 minutes from ambient to 350 °C 
Cooling Times  20 minutes from ambient to –25 °C  15 minutes from 350 °C to 100 °C 
Stabilization Time  7 minutes 
Immersion Depth  124 mm (4.875") 
Inserts Insert A, B, C, or D included (specify when ordering) 
Outside Insert Dimensions  31.8 mm dia. x 124 mm (1.25 x 4.88 in) 
Computer Interface  RS-232 interface
Power  230 V ac (± 10 %), 0.7 A, switchable, 50/60 Hz, 150 W  230 V ac (± 10 %), 2.2 A, switchable, 50/60 Hz, 500 W 
Size (WxHxD)  143 x 261 x 245 mm
(5.63 x 10.25 x 9.63 in) 
152 x 86 x 197 mm
(6 x 3.375 x 7.75 in) 
Weight  5.7 kg (12 lb)  2.7 kg (6 lb) 
NIST-Traceable Certificate  Data at –25 °C, 0 °C, 25 °C, 50 °C, 75 °C, 100 °C, and 140 °  Data at 50 °C, 100 °C, 150 °C, 200 °C, 250 °C, 300 °C, and 350 °C 
Document Downloads
Fluke Industrial Temperature Calibrator Selection Guide Manual/Guide
Fluke 9140-X-256 Field Dry Well Temperature Calibrator - User Guide Supplement Manual/Guide
Fluke 9140-X-256 Field Dry Well Temperature Calibrator - User Guide Manual/Guide
Additional Information
SKU
Fluke 9140-X-256
Manufacturer Part Code
3015868

Customer Reviews

 
Fluke 9140-X-256 Field Dry Well Temperature Calibrator –Choice of Disc
£3,069.00
£3,682.80 inc vat
£3,069.00
£3,682.80 inc vat