The Fluke 9100S-X-256 Handheld Dry-Well Tester – Choice of Block is suitable for checking the accuracy of RTDs, thermocouples and small bimetal thermometers. It is available in six models which vary in regards to the block insert supplied with the instrument. For further information, please see the table below.
Product Code | Product Name | Name of Block | Wells in Block Insert |
9100S-A-256 | Fluke 9100S-A-256 Handheld Dry-Well | A | 1/4" (6.4mm), 5/32" (4mm), 3/16" (4.8mm), 1/16" (1.6mm), 3/16" (4.8mm), 1/8" (3.2mm) |
9100S-B-256 | Fluke 9100S-B-256 Handheld Dry-Well | B | 3/8" (9.5mm), 3/16" (4.8mm), 1/8" (3.2mm), 1/4" (6.4mm) |
9100S-C-256 | Fluke 9100S-C-256 Handheld Dry-Well | C | 1/2" (12.7mm) and 3/16" (4.8mm) |
9100S-D-256 | Fluke 9100S-D-256 Handheld Dry-Well | D | 3mm, 4mm, 6mm, 3mm, 4mm, 6mm |
9100S-P-256 | Fluke 9100S-P-256 Handheld Dry-Well | C (PON) | 1/2" (12.7mm) and 3/16" (4.8mm) |
9100S-Y-256 | Fluke 9100S-Y-256 Handheld Dry-Well | Custom Block | Block is customised to the user's requirements |
Its compact size and extensive temperature range (35°C/ 95°F to 375°C / 707°F) makes it suitable for carrying out a number applications in-the-field. This small tester (HxW: 2.5” x 5”) is lightweight and easy to transport. It is also easy-to-use; after plugging it in and switching it on, the user need only follow these few steps in order to ascertain the degree of error present in the instrument-under-investigation:
1.) Using the front panel buttons, set the temperature.
2.) Insert the probe-under-investigation into an appropriately sized well.
3.) Compare the probe’s reading to the reading indicated on the Fluke 9100S-X-256 Handheld Dry-Well Tester’s display. Alternatively, the probe’s reading can be compared to an external reference.
4.) The difference between the measurements indicates the error in the probe.
The readings acquired by the Fluke 9100S-X-256 Handheld Dry-Well Tester have an accuracy of ± 0.25°C to 0.5°C, depending on the setpoint temperature. Further to this, the tester has a stability of ± 0.07°C to 0.3°C, taking just five minutes to reach stabilisation. Readings are indicated on the Fluke 9100S-X-256 Handheld Dry-Well Tester’s display, which has a resolution of 0.1 degrees. These accuracies, stabilities and resolutions are made possible as a result of the integrated Fluke calibration temperature controller.
Finally, the Fluke 9100S-X-256 Handheld Dry-Well Tester is also supplied with an RS-232 interface and Fluke’s Interface-It Software, facilitating the user’s ability to monitor and control temperatures remotely.
The Fluke 9100S-X-256 Handheld Dry-Well Tester – Choice of Block is a portable, adaptable, sophisticated tester, suitable for evaluating a variety of pressure sensing instruments.
Fluke 9100S-X-256 Handheld Dry-Well Tester – Choice of Block Key Features
- Check the accuracies of RTDs, thermocouples and small bimetal thermometers
- Available in six models with varying block inserts
- Temperature range: 35°C/ 95°F to 375°C / 707°F
- Compact size: 2.5” x 5” (HxW)
- Lightweight
- Easy to transport
- Plug in and switch on
- Use the front panel buttons to set the temperature
- Insert the probe-under-investigation into the appropriately sized well
- Compare the probe’s reading to the reading indicated on the Fluke 9100S-X-256 Handheld Dry-Well Tester’s display
- Alternatively, the probe’s reading can be compared to an external reference
- The difference between the measurements indicates the error in the probe
- Has an accuracy of ± 0.25°C to 0.5°C, depending on the setpoint temperature
- Stability of ± 0.07°C to 0.3°C
- Display resolution: 0.1 degrees
- Integrated Fluke calibration temperature controller
- RS-232 interface and Fluke Interface-It software are included
- Can be used to monitor and control temperatures from the user’s PC
- Portable, adaptable, sophisticated tester, suitable for evaluating a variety of pressure sensing instruments
What’s Included?
- Your Choice of Fluke 9100S-X-256 Handheld Dry-Well Tester – Choice of Block
- NIST-Traceable Calibration
- RS-232 Interface
- Fluke Interface-It Software
Fluke 9100S-X-256 Handheld Dry-Well Tester – Choice of Block Technical Specifications
Range | 35 °C to 375 °C (95 °F to 707 °F |
Accuracy | ± 0.25 °C at 50 °C; ± 0.25 °C at 100 °C; ± 0.5 °C at 375 °C |
Stability | ± 0.07 °C at 50 °C; ± 0.1 °C at 100 °C; ± 0.3 °C at 375 °C |
Well-to-Well Uniformity | ± 0.2 °C with sensors of similar size at equal depths within wells |
Heating Times | 35 °C to 375 °C: 9.5 minutes |
Stabilization | 5 minutes |
Cooling Times | 375 °C to 100 °C: 14 minutes |
Well Depth | 102 mm (4 in);1.6 mm (1/16 in) hole is 89 mm (3.5 in) deep |
Power | 230 V ac (± 10 %), 0.8 A, 45–55 Hz, 175 W |
Size (HxWxD) | 57 x 125 x 150 mm (2.25 x 4.9 x 6.1 in) |
Weight | 1 kg (2 lb 3 oz) |
Computer Interface | RS-232 interface with Interface-it Software |
NIST-Traceable Calibration | Data at 50 °C, 100 °C, 150 °C, 200 °C,250 °C, 300 °C, and 375 °C |