Highly accurate, packed with functionality and extremely tough (drop tested to a height of 1m), the Fluke 87V is the perfect digital multimeter for use in industrial conditions including testing and general maintenance in power distribution, plant automatic and for use on all electro-mechanical industrial equipment.
Fluke's 87V is designed to accurately measure complex signals, allowing it to be used to measure adjustable speed drives with exceptional accuracy. With this technology it's possible to determine accurate measurements of noisy pulse-width modulated AC voltage, accurately measure frequency (motor speed) and special built-in shielding blocks high frequency, high-energy noise generated by large drive systems.
The Fluke 87V digital multimeter is also perfect for all standard electrical measurements; this powerful, true RMS digital multimeter can measure AC/DC voltage and current, resistance, capacitance, duty cycle, frequency, temperature, conductance and continuity.
This digital multimeter includes a huge range of additional functions including auto/manual ranging, MIN/MAX/AVERAGE recording, two-level backlight, data hold, analogue bargraph and much, much more.
Voltage DC | |
Maximum Voltage | 1000V |
Accuracy | ±(0.05% + 1) |
Maximum Resolution | 10μV |
Voltage AC | |
Maximum Voltage | 1000V |
Accuracy | ±(0.7% + 2) true RMS |
AO Bandwidth | 20kHz with low pass filter; 3dB @ 1kHz |
Maximum Resolution | 0.1mV |
Current DC | |
Maximum Current | 10A (20A for 30 seconds max) |
Accuracy | ±(0.2% + 2) |
Maximum Resolution | 0.01μA |
Current AC | |
Maximum Current | 10A (20A for 30 seconds max) |
Accuracy | ±(0.1%+2) true RMS |
Maximum Resolution | 0.1μA |
Resistance | |
Max Resistance | 50MΩ |
Accuracy | ±(0.2% + 1) |
Maximum Resolution | 0.1Ω |
Capacitance | |
Maximum Capacitance | 9999μF |
Accuracy | ±(1%+2) |
Maximum Resolution | 0.01nF |
Frequency | |
Maximum Frequency | 200kHz |
Accuracy | ±(0.005%+1) |
Maximum Resolution | 0.01Hz |
Duty Cycle | |
Maximum Duty Cycle | 99.9% |
Accuracy | ±(0.2% per kHz + 0.1%) |
Maximum Resolution | 0.1% |
Temperature | |
Measurement Ranges | -200 to 1090°C -328 to 1994°F (excluding probe) |
Conductance | |
Maximum | 60.00nS |
Accuracy | ±(1.0% + 10) |
Maximum Resolution | 0.01nS |
Diode | |
Range | 3V |
Resolution | 1mV |
Accuracy | ±(2%+1) |
Duty Cycle | |
Accuracy | Within ±(0.2% per kHz +0.1%) |
Environmental Specifications | |
Operating Temperature | -20 to +55°C |
Storage Temperature | -40 to +60°C |
Humidity (Without Condensation) | 0 to 90% (0 to 35°C) 0 to 70% (35 to 55°C) |
Operating Altitude | 2000m |
Safety Specifications | |
Overvoltage Category | EN 61010-1 to 1000V CAT III, 600V CAT IV |
Agency Approvals | UL, CSA, T-V, VDE listed |
Mechanical/General Specifications | |
Size | 201 x 98 x 52mm (with holster) |
Weight | 355g (624g with holster) |
Display | Digital - 6000 counts, updates 4/sec (19999 counts in high resolution mode) Analogue - 32 segments, updates 40/sec Frequency - 19999 counts, updates 3/sec at >10Hz |
Warranty | Lifetime |
Battery Life | Alkaline - 400 hours typical (without backlight) |
Shock | 1m drop-tested per IEC 61010-1: 2001 |
Vibration | Per MIL-PRF-28800 for a class 2 instrument |