This is the Fluke 805 FC - a reliable, repeatable and accurate way to check bearing and overall vibration on a wide variety of equipment.
Portable and lightweight, the Fluke 805 FC gives professional technicians all the tools they need for frontline mechanical troubleshooting, delivering consistent, repeatable, severity-scaled results.
No more guesswork and complex setup; with the Fluke 805 FC as part of your equipment, you'll find out just how easy it is to gain reliable measurements of the vibration of machinery.
Shaped like a standard vibration pen but with a wide variety of expanded features compared to many models on the market, the Fluke 805 FC is the tool of choice for many vibration professionals across the globe.
This meter includes many different benefits, including:
The Fluke 805 FC is part of the Fluke Connect family of testing tools.
This technology allows you to connect your 805 FC wirelessly to a smartphone or tablet to export results, share your findings and much more.
Take a look at the video below for an introduction to the capabilities of Fluke Connect:
Fluke's 805 FC vibration meter is ideal for measuring on the following:
Specifications | |
---|---|
Low frequency range (overall measurement) | 10 Hz to 1,000 Hz |
High frequency range (CF+ measurement) | 4,000 Hz to 20,000 Hz |
Severity levels | Good, satisfactory, unsatisfactory, unacceptable |
Vibration limit | 50 g peak (100 g peak-peak) |
A/D converter | 16-bit |
Signal to noise ratio | 80 dB |
Sampling rate | Low frequency: 20,000 Hz High frequency: 80,000 Hz |
Real time clock backup | Coin battery |
Sensor | |
Sensitivity | 100 mV g ± 10% |
Measurement range | 0.01 g to 50 g |
Low frequency range (overall measurement) | 10 Hz to 1,000 Hz |
High frequency range | 4,000 Hz to 20,000 Hz |
Resolution | 0.01 g |
Accuracy | At 100 Hz ± 5% of measured value |
Amplitude Units | |
Acceleration | g, m/sec² |
Velocity | in/sec, mm/sec |
Displacement | mils, mm |
Infrared Thermometer (Temperature Measurement) | |
Range | -20 °C to 200 °C (-4 °F to 392 °F) |
Accuracy | ±2 °C (4 °F) |
Focal length | Fixed, at ~3.8 cm (1.5") |
External Sensor | |
Note: Fluke supports but does not provide external sensors | |
Frequency range | 10 Hz to 1,000 Hz |
Bias voltage (to supply power) | 20 V dc to 22 V dc |
Bias current (to supply power) | Maximum 5 mA |
Firmware | |
External interfaces | USB 2.0 (full speed) communication |
Data capacity | Database on internal flash memory |
Upgrade | Through USB |
Memory | Up to 3,500 measurements |
Radiated Emission | |
Electrostatic discharge: burst | Standard EN 61000-4-2 |
Electromagnetic interference | Standard EN 61000-4-3 |
RE | Standard CISPR 11, Class A |
Environmental | |
Operating temperature | -20 °C to 50 °C (-4 °F to 122 °F) |
Storage temperature | -30 °C to 80 °C (-22 °F to 176 °F) |
Operating humidity | 10% to 95% RH (non-condensing) |
Operating/storage altitude | Sea level to 3,048 meters (10,000 feet) |
IP rating | IP54 |
Vibration limit | 500g peak |
Drop test | 1 meter |
General Specifications | |
Battery type | AA (2) Lithium Iron Disulfide |
Battery life | 250 measurements |
Size (L x W x H) | 24.1 cm x 7.1 cm x 5.8 cm (9.5 in x 2.8 in x 2.3 in) |
Weight | 0.40 kg (0.89 lb) |
Connectors | USB mini-B 7-pin, external sensor jack (SMB connector) |