The Fluke 789 ProcessMeter™, IR3000FC Connector & A3004FC Clamp Meter Kit is a troubleshooting kit ideal for electricians and instrumentation professionals.
The Fluke 789 ProcessMeter™, IR3000FC Connector & A3004FC Clamp Meter Kit includes the following Fluke instruments:
Please see the descriptions below for further information regarding the aforementioned products.
The Fluke 789 ProcessMeter™ combines the capabilities of the Fluke 87 Digital Multimeter with an mA loop calibrator. As a result, this compact test tool is suitable for troubleshooting, as well as calibrating current loop.
The Fluke 789 ProcessMeter™ can be used to measure, source and simulate DC current up to 20mA and is able to display mA readings alongside the percentage of the scale. Its Manual Step (100%, 25%, Coarse and Fine), Auto Step and Auto Ramp modes allow the user to adjust the current.
The Fluke 789 ProcessMeter™ can also provide a 24V loop power supply and includes a HART mode with loop power which adds a 250Ω resistor.
Equipped with the precision of a 1000V, 440mA true-RMS digital multimeter, the Fluke 789 ProcessMeter™ is capable of measuring frequency up to 20kHz and performing diode tests. It also features a continuity beeper. The Fluke 789 ProcessMeter™ has also been designed to comply with 1000V IEC 61010 CAT III and 600V CAT IV standards for digital multimeters.
The Fluke 789 ProcessMeter™’s Min, Max, Average, Hold and Relative measurement modes allow the user to determine and view the measurements most relevant to his/her application. Using the Fluke Connect™ mobile app and the included Fluke IR3000FC Connector the user can wirelessly log data to his/her smartphone allowing him/her to monitor data remotely. The user can also share measurements with colleagues from the field using the Fluke Connect™ app enabling teams to make collaborative, real-time decisions.
Finally, the Fluke 789 ProcessMeter™’s battery is externally accessible facilitating easy battery changes.
The Fluke 789 ProcessMeter™ is an accurate, versatile and easy-to-use combined digital multimeter and mA loop calibrator.
The Fluke IR3000FC Connector facilitates a connection between the Fluke 789 ProcessMeter™ and the Fluke Connect™ App, allowing the user to log measurements wirelessly to his/her smartphone or tablet.
Logging data to the Fluke Connect™ App allows the user to monitor measurements remotely and in real-time enabling quicker identification and diagnosis of potential issues. Data can also be shared with colleagues via the Fluke Connect™ App allowing teams to make collaborative, real-time decisions. Additionally, the Fluke Connect™ App can be used to graph measurements.
The Fluke IR3000FC Connector fits over the Fluke 789 ProcessMeter™’s IR port and supports Android 4.4 smartphones and above, as well as iOS 4s smartphones and above. The Fluke IR3000FC Connector can be upgraded via USB.
The Fluke IR3000FC Connector is a useful addition to the Fluke 789 ProcessMeter™ as it enables remote, real-time and collaborative data monitoring and decisions.
The Fluke A3004FC Wireless 4-20mA DC Clamp Meter is a current clamp meter designed to communicate measurements wirelessly to compatible Fluke instruments and/or to the user’s smartphone/ tablet via the Fluke Connect™ App.
It can be placed in awkward-to-access or potentially hazardous areas while the user views readings from a more convenient or safe location; to this end, the Fluke A3004FC Wireless 4-20mA DC Clamp Meter includes a detachable clamp with an extension cable.
The Fluke A3004FC Wireless 4-20mA DC Clamp Meter is suitable for testing and troubleshooting 4-20mA control loops used with drive systems or PLCs, and building energy management systems. It is able to measure 4 to 20mA signals without breaking the loop.
The Fluke A3004FC Wireless 4-20mA DC Clamp Meter is compatible with the following Fluke Connect™ enabled products:
Additionally, when used with the Fluke Connect™ App the operator can share data with colleagues without leaving the field, thereby enabling collaborative, real-time decisions and improving work efficiency. He/she can also view results graphically. Logging data to a PC allows the user to perform data analysis.
The Fluke A3004FC Wireless 4-20mA DC Clamp Meter is able to log up to 65 000 measurements over time; these measurements can be downloaded from the unit using a Fluke Connect™ Wireless USB Adapter.
The Fluke A3004FC Wireless 4-20mA DC Clamp Meter is an easy-to-use, efficient and ergonomic clamp meter suitable for use as a standalone instrument or as part of a system.
Spend £150+ (Ex VAT) on any qualified Fluke or Beha-Amprobe product(s) and claim a free tool of your choice from the list at Fluke Promotion. Valid February 17 2025 - July 31 2025.
Claims are made direct to Fluke. Terms and conditions apply.
Specifications | ||
Current measurement | Range | 0-1 A AC or DC |
Resolution | 1 mA | |
Accuracy | 0.2% + 2 LSD (DC) | |
Range | 0-30 mA | |
Resolution | 0.001 mA | |
Accuracy | 0.05% + 2 lSD | |
Current sourcing | Range | 0-20 mA or 4-20 mA |
Resolution | 0.05% of span | |
Drive capability | 24 V Compliance or 1200 Ω @ 20 mA | |
Frequency | to 19.999 kHz, 0.005% + 1 LSD | |
Continuity | Beeps for resistance < 100 Ω | |
Voltage measurement | Range | 0-1000 V AC (true-rms) or DC |
Resolution | 0.1 mV to 1.0 V | |
Accuracy | 0.1% Rdg + 1 LSD (VDC) | |
Resistance measurement | to 40 MΩ, 0.2% + 1 LSD | |
Diode test | 2.0 V shoes diode voltage drop | |
Display current and % of span | Yes | |
Auto Step, Auto Ramp | Yes | |
Environmental Specifications | ||
Operating temperature | -20°C to 55°C | |
Storage temperature | -40°C to 60°C | |
Humidity (without condensation) | 95% up to 30°C | |
75% up to 40°C | ||
45% up to 50°C | ||
35% up to 55°C | ||
Safety Specifications | ||
Electrical safety | Designed in accordance with IEC 1010-1, ANSI/ISA S82.01-1994 and CAN/CSA C22.2 No 1010.1-92 | |
Overvoltage category | IEC 1010-1 CAT III 1000 V | |
IEC 1010-1 CAT IV 600 V | ||
Maximum voltage | 1000 V RMS | |
Mechanical and General Specifications | ||
Size (H x W x L) | 50 x 100 x 203 mm (1.25 x 3.41 x 7.35 in) | |
Weight | 610 g (1.6 lbs) | |
Batteries | 4 AA alkaline batteries | |
Warranty | 3 years | |
Battery life | 140 hours typical (measurement), 10 hours typical (sourcing 20 mA) | |
Shock and vibration | Random, 2 g, 5-500 Hz | |
1 meter drop test |
Battery type | Two AAA Alkaline batteries, ANSI-24A IEC-LR03 | |
Battery life | 6 hours of continuous transmission | |
RF communications | 2.4 GHz ISM Band | |
RF communication range | Open-air, unobstructed | Up to 20 m |
Obstructed, sheetrock wall | Up to 6.5 m | |
Obstructed, concrete wall or steel electrical enclosure | Up to 3.5 m | |
Temperature operating | -10°C to 50°C | |
Storage | -20°C to 60°C | |
Certifications | CSA, FCC, CE, IC | |
Warranty from Fluke | Three years | |
Weight | 80 g | |
Size (H x W x L) | 3.2 x 7.6 x 6.4 cm (1.25 x 3.0 x 2.5 in) | |
Compatibility | Fluke 287, 289, 789 |
DC Current Function | |
Range | 0.05 mA to 20.99 mA DC |
21.0 mA to 99.9 mA DC | |
Resolution | 0.01 mA |
0.1 mA | |
Accuracy | 0.2% ± 5 digits |
1.0% ± 5 digits | |
Specifications | |
LCD w/backlight | 3 ½ digits |
Log rate/Interval | 1 sec minimum/adjustable by PC or front pannel |
Battery type | 2 AA |
NEDA 15 A | |
IEC LR6 | |
Battery life | 45 hours |
Memory | Record up to 65,000 readings |
RF communications | 2.4 GHz ISM Band |
RF communication range | Open-air, unobstructed: Up to 20 m |
Obstructed, sheetrock wall: Up to 6.5 m | |
Obstructed, concrete wall or steel electrical enclosure: Up to 3.5 m | |
Operating temperature | -10°C to +50°C |
Storage temperature | -40°C to +60°C |
Temperature coefficient | Add 0.1 X (specified accuracy) /°C (< 18°C or > 28°C) |
Operative humidity | 90% at 35°C |
75% at 40°C | |
45% at 50°C | |
Altitude | Operating 2,000 m |
Storage 12,000 m | |
EMC | EN 61326-1:2013 |
Maximum voltage between terminal and earth ground (module) | 30 V DC or AC rms |
Certifications | CSA C-US |
CE | |
FCC: T68-FBLE | |
IC: 6627A-FBLE | |
Ingress Protection (IP) rating | IP42 |
Jaw opening | 4.5 mm |
Size (HxWxD) | 16.5 mm x 6.35 cm x 1.4 cm (6.5 in x 2.5 in x 1.4 in) |
Weight | 0.299 kg (0.8 lb) |
Note | Not compatible with Fluke CNX test tools. |