Gage pressure modules have one pressure fitting and measure the pressure concerning atmospheric pressure. Differential pressure modules have two pressure fittings and measure the difference between the applied pressure on the high fitting versus the low fitting. Each module is clearly labelled for range, overpressure, and media compatibility. All modules include NPT, metric (BSP), and M20 adapters. Available from 0 to 15 Psi (0 to 1 bar) to 0 to 10000 Psi (0 to 700 bar).

Product Ranges

  • FLUKE-750R04 Pressure Module 0 to 15 Psi (0 to 1 bar)
  • FLUKE-750R06 Pressure Module 0 to 100 Psi (0 to 7 bar)
  • FLUKE-750R07 Pressure Module 0 to 500 Psi (0 to 35 bar)
  • FLUKE-750R08 Pressure Module 0 to 1000 Psi (0 to 70 bar)
  • FLUKE-750R27 Pressure Module 0 to 300 Psi (0 to 20 bar)
  • FLUKE-750R29 Pressure Module 0 to 3000 Psi (0 to 200 bar)
  • FLUKE-750R30 Pressure Module 0 to 5000 Psi (0 to 340 bar)
  • FLUKE-750R31 Pressure Module 0 to 10000 Psi (0 to 700 bar)
Tech Specs
Reference Module Specifications
Model Parameter / Range Burst Rating5 Hi Side Media2 Lo Side Media2
750R044 0 to 15 psi (0 to 1 bar) 3X Dry air Dry air
750R064 0 to 100 psi (0 to 7 bar) 4X 316 SS
750R07 0 to 500 psi (0 to 35 bar) 4X 316 SS
750R084 0 to 1000 psi (0 to 70 bar) 3X 316 SS
750R27 0 to 300 psi (0 to 20 bar) 4X 316 SS
750R29 0 to 3000 psi (0 to 200 bar) 3X 316 SS
750R30 0 to 5000 psi (0 to 340 bar) 3X 316 SS
750R314 0 to 10000 psi (0 to 700 bar) 2X 316 SS

 

Model Reference Uncertainty3 Total Uncertainty 1-Year (15-35°C) Total Uncertainty 1-Year1 Total Uncertainty 6-Month (15-35°C) Total Uncertainty 6-Month1
750R044 ±0.01% of FS ±0.02% of FS ±0.04% of FS ±0.015% of FS ±0.035% of FS
750R064 ±0.01% of FS ±0.02% of FS ±0.04% of FS ±0.015% of FS ±0.035% of FS
750R07 ±0.01% of FS ±0.02% of FS ±0.04% of FS ±0.015% of FS ±0.035% of FS
750R084 ±0.01% of FS ±0.02% of FS ±0.04% of FS ±0.015% of FS ±0.035% of FS
750R27 ±0.01% of FS ±0.02% of FS ±0.04% of FS ±0.015% of FS ±0.035% of FS
750R29 ±0.01% of FS ±0.02% of FS ±0.04% of FS ±0.015% of FS ±0.035% of FS
750R30 ±0.01% of FS ±0.02% of FS ±0.04% of FS ±0.015% of FS ±0.035% of FS
750R314 ±0.01% of FS ±0.02% of FS ±0.04% of FS ±0.015% of FS ±0.035% of FS

 

1 - Total uncertainty, % of full span for temperature range 0°C to +50°C, one year interval. Total uncertainty, 1.0% of full span for temperature range -10°C to 0°C, one-year interval. No 6-month specification available for range -10°C to 0°C.

2 - “Non-corrosive gasses” indicates Dry air or non-corrosive gas as compatible media. “Stainless Steel 316-SS” indicates media compatible with Type 316 Stainless Steel.

3 - Reference Uncertainty is the specification for as left data for 24 hours.

4 - When reference class modules are used with fixed resolution products (717, 718, 719 series, 725, and 726) calibrators add ±1 count to the overall accuracy specification.

5 - Burst rating specification refers to the multiplier times the full scale of the module for the rated burst pressure.