The Fluke 729 Automatic Pressure Calibrator – Choice of Range is available in three models which vary in regards to their pressure ranges. Please see the table below for further details.

Product Code Product Name  Psi Range Bar Range kPa Range
FLK-729 30G Fluke 729 Automatic Pressure Calibrator - 2 Bar -12.0000 to 30.0000 psi -0.82737 to 2.06842 bar -82.737 to 206.843 kPa
FLK-729 150G Fluke 729 Automatic Pressure Calibrator - 10 Bar -12.000 to 150.000 psi -0.8273 to 10.3421 bar -82.73 to 1034.21 kPa
FLK-729 300G Fluke 729 Automatic Pressure Calibrator - 20 Bar -12.000 to 300.000 psi -0.8273 to 20.6843 bar -82.73 to 2068.43 kPa

PLEASE NOTE: the models listed above do not have wireless capabilities and so they cannot be connected to Fluke Connect®. For pressure calibrators with this capability, please see the Fluke 729FC Automatic Pressure Calibrator with Wi-Fi for Fluke Connect®, available here.

The Fluke 729 Automatic Pressure Calibrator can be used for the comprehensive calibration of pressure instruments. It includes an electric pump for automatic pressure creation and maintenance. Each model is able to produce pressure to the maximum value within its range, for example, the Fluke 729 Automatic Pressure Calibrator 20 bar can produce pressure up to 300 psi.

This instrument is easy to use, the operator need only enter the desired pressure value and the calibrator will automatically generate pressure to this value.

Moreover, the Fluke 729 Automatic Pressure Calibrator performs leak tests in order to verify test setups; if it should detect a minor leak in a test hose it will automatically compensate for this by adjusting the pressure generated. This eliminates the need for the manual adjustment of test setups and the need for the user to generate pressure adjustments through physical pumping or turning a vernier.

Furthermore, this sophisticated instrument can be programmed to test the device-under-investigation at multiple points. In order to do this, the user fills out a test template on the Fluke 729 Automatic Pressure Calibrator, detailing the start and end point and as many test points as are required. The Fluke 729 Automatic Pressure Calibrator will then complete these tests and record the applied pressure, the measured mA and % error for each test point. If the Fluke 729 Automatic Pressure Calibrator detects abnormal or out-of-tolerance results it will indicate these to the user via the bright, graphical, dual/triple channel, colour display.  

The Fluke 729 is able to measure, source and simulate current signals between 4 and 20mA, ensuring that the Fluke 729 Automatic Pressure Calibrator can be used to test I/Ps and mA loop modules. This calibrator can also generate a 24V loop power supply optimised for powering transmitters during standalone tests in which the transmitter is disconnected from the control system.

In addition to this, the Fluke 729 Automatic Pressure Calibrator contains a HART communication feature for testing HART smart transmitters. It can perform the following operations:

  • mA output trim: facilitates trimming to applied values and pressure zero trimming
  • Light configuration: change transmitter tags, measurement units and ranges
  • Set fixed mA outputs for troubleshooting
  • Read device configuration and variables
  • Read device diagnostics

When using the HART communication function all commands are in English, however, all other menu options can be displayed in the user’s preferred language.

The extensive measurement capabilities and versatility of this meter are not limited to its internal ranges and functions. It can be used with Fluke’s 700 and 750 series Pressure Modules (NOT included) should the user require a different pressure range or resolution. Moreover, the Fluke 729 Automatic Pressure Calibrator is compatible Fluke’s 720RTD Probe (NOT included), which facilitates the calibrator’s ability to measure temperature for the purposes of custody transfer calibrations.

All results collected by the Fluke 729 Automatic Pressure Calibrator may be uploaded to Fluke’s DPCTrack™ Calibration Management Software (NOT included). Using this software, the operator may organise his/her data into reports, as well as created scheduled tests.

Finally, in addition to its adaptability, sophistication and extensive measurement capabilities, the Fluke 729 Automatic Pressure Calibrator is also rugged and ideal for fieldwork. It features a robust casing and has been drop tested from 1m. Its three-year warranty all but guarantees this product’s longevity, whilst its semi-rigid carrying case not only protects this instrument from the elements but also provides an efficient and practical way for the user to transport test hoses, fittings, test leads and small hand tools.

The Fluke 729 Automatic Pressure Calibrator has been optimised for pressure technicians, it is a practical, adaptable, versatile, sophisticated instrument which is suitable for use in a multitude of challenging environments.

Fluke 729 Automatic Pressure Calibrator – Choice of Range Key Features

  • Available in three models with different pressure ranges
  • Do NOT contain wireless connectivity, CANNOT be connected to Fluke Connect®
  • Can be used to calibrate pressure equipment comprehensively and accurately
  • Electric pump for the automatic generation of the user-stipulated pressure
  • Each model is able to produce pressure to the maximum value of its range
  • Enter the desired pressure and the calibrator will automatically generate pressure to this value
  • Integrated leak tests to verify test setups
  • If a test hose leak is detected the calibrator will automatically finely adjust the pressure to compensate
  • Removes the need for manual pumping or adjustment of the test setup
  • Can be programmed to test the module-under-investigation at multiple points
  • Complete the test template with the start and end values and the number of test points required
  • Will automatically complete tests and record the pressure applied at each test point, the measured mA and the %error
  • Will indicate abnormal measurements on the display
  • Bright, graphical, dual/triple channel, colour display
  • Measure, source and simulate current signals between 4 and 20mA
  • Capable of testing I/Ps and mA loop modules
  • Generate a 24V loop power supply for powering transmitters during standalone tests
  • HART communication for testing HART smart transmitters
  • HART communication is always in English
  • Other menu options may be displayed in the user’s language of choice
  • May be used with Fluke’s 700 and 750 Pressure Modules (NOT included)
  • Measure temperature with Fluke’s 720RTD Probe (NOT included)
  • Data can be uploaded to and managed using Fluke’s DPCTrack™ Calibration Management Software (NOT included)
  • Rugged casing
  • Drop tested from 1m
  • Three-year warranty from Fluke
  • Semi-rigid carrying case protects the instrument and its accessories
  • Semi-rigid carrying case facilitates the user’s ability to transport the instrument and accessories between sites
  • Optimised for field work

What’s Included?

  • Your Choice of Fluke 729 Automatic Pressure Calibrator – Choice of Range
  • Soft Case
  • Stackable Test Leads
  • AC280 Hook Clips
  • Alligator Clips
  • Test Probes
  • Magnetic Hanger Kit
  • Carrying Strap
  • Quick Start Guide
  • Safety Sheet
  • Power Supply
  • Rechargeable Battery (installed)
  • Hose Kit with Push-Fit Adapters
  • Hanging Clip
  • USB Cable
  • 1/8 in FNPT to 1/ 4 in FNPT Adapter
  • 1/8 in FNPT to F-M20 Adapter
  • 1/8 in FNPT to 1/ 4 in FBSP Adapter
  • PTFE Tape
  • 2x Sintered Filters
  • Water Trap Drain
  • Valve Tuning Hoses
  • 3-Year Warranty from Fluke

Fluke 729 Automatic Pressure Calibrator – Choice of Range Technical Specifications

Electrical Specifications 
All specifications are valid to 110% of range, except 24 mA source and simulate which are valid to 100% of range.
Ranges
mA measure, source and simulate 0 mA to 24 mA
Volts dc measure 0 V dc to 30 V dc
Resolution
mA dc source, simulate and measure 1 μA
Voltage dc measurement 1 mV
Accuracy 0.01% ±2 LSD all ranges (at 23 °C ±5 °C)
Stability 20 ppm of full scale /°C from -10 °C to +18 °C and 28 °C to +50 °C
mA simulate external voltage requirement 12 V dc to 30 V dc
Loop compliance voltage 24 V dc @ 20 mA
mA simulate external voltage requirement 12 V dc to 30 V dc
Temperature measurement only/100 Ω Pt(385) RTD -50 °C to 150 °C (-58 °F to 302 °F)
Temperature resolution 0.01 °C (0.01 °F)
Temperature accuracy ±0.1 °C (0.2 °F) ±0.25 °C (±0.45 °F) combined uncertainty when using 720 RTD probe (optional accessory)
Drive capability 1200 Ω without HART resistor, 950 Ω with internal HART resistor
Mechanical Specification
Size (HxWxL) 7 x 27.94 x 17.27 cm (2.75 x 11 x 6.8 in)
Weight 6.5 lbs., 2.95 kg
Ingress protection IP54
Environmental Specifications 
Operating temperature -10 °C to 50 °C for measurement, 0 °C to 50 °C for pressure control
Operating temperature with battery -10 °C to 40 °C
Battery will only charge to 40 °C
Storage temperature -40 °C to 60 °C
Operating altitude 3000 m
Storage altitude 13000 m
Fluke 729 and 729FC Automatic Pressure Calibrator - Datasheet Datasheets Fluke 729 and 729FC Automatic Pressure Calibrator - Instruction Sheet Manuals & Guides Fluke 729 and 729FC Automatic Pressure Calibrator - Calibration Manual Manuals & Guides Fluke 729 and 729 FC Automatic Pressure Calibrator - User Manual Manuals & Guides Fluke 729 and 729FC Automatic Pressure Calibrator - Safety Information Notes & Other Fluke 729 and 729FC Automatic Pressure Calibrator - Security Procedures Notes & Other