All Fluke Calibration Products

Fluke 7109A Portable Calibration Bath – Process Electronics Optional

SKU
Fluke 7109A
Rating:
0%
(0)
Reward Points
:
11055
£11,055.60 £9,213.00
Made to Order
Free UK Delivery*
Advice & Support Call 01642 931329 or contact us
Price Match We won't be beaten, let us know
Free Aftersales Support
Fluke 7109A Portable Calibration Bath – Process Electronics Optional - Angled Back

The Fluke 7109A Portable Temperature Calibration Bath – Process Electronics Optional is designed to calibrate multiple sanitary sensors and/or RTDs simultaneously. It is of particular use to facilities managers, production engineers and calibration technicians working in clean process industries and is particularly well suited to calibrating sanitary sensors and RTDs used in pharmaceutical, biotechnological, and food production process manufacturing plants.

The Fluke 7109A Portable Temperature Calibration Bath – Process Electronics Optional is available in two models, one with process electronics and one without process electronics. The addition of process electronics facilitates the user’s ability connect an external reference probe to the calibration bath. In all other respects, the models are the same. Please see the table below for further details.

Product Code Product Name Process Electronics? External Reference Probe Connectivity
7109A-256

Fluke 7109A-256 Portable Temperature Calibration Bath - WITHOUT Process Electronics 

NO An external reference probe CANNOT be connected
7109A-P-256 Fluke 7109A-P-256 Portable Temperature Calibration Bath - WITH Process Electronics  YES An external reference probe CAN be connected.

The design of the Fluke 7109A Portable Temperature Calibration Bath has been optimised to increase the speed with which sanitary sensors and RTDs may be calibrated, subsequently reducing the downtime of process manufacturing plants. This instrument includes a tank with a depth of 154mm and an opening of 122mm², this allows the user to calibrate a number of variously sized sensors simultaneously and it provides room for a reference thermometer. In addition to this, the calibration bath includes an adjustable probe fixture capable of holding up to four tri-clamp sensors securely in place during the calibration.

Also adding to the Fluke 7109A Portable Temperature Calibration Bath’s efficiency is its quick heating, cooling and stabilisation times. On average the calibration bath takes 10 minutes to stabilise and is able to heat and cool to the following temperatures in the following times:

  • -25°C to 25°C in thirty-five minutes
  • 25°C to 140°C in fifty-five minutes
  • 140°C to 25°C in forty-five minutes
  • 25°C to -25°C in seventy-five minutes

The Fluke 7109A Portable Temperature Calibration Bath has a total temperature range of -25°C to 140°C, making it suitable for calibrating the following temperature sensor applications performed in clean process manufacturing:

  • Pharmaceutical bioreactors (-10°C to 100°C)
  • Steam-in-place process (122°C to 140°C)
  • Autoclave sterilisation (120°C to 135°C)
  • Food storage freezers (down to -25°C)
  • Food processing (0°C to 140°C)

This calibration bath provides a viable alternative to micro baths and dry-block calibrators, especially as it includes a display accuracy of ±0.1°C which improves upon the accuracy of traditional micro bath and dry-block calibrators. This display accuracy accounts for all sources of errors such as calibration uncertainty, stability, uniformity and repeatability, allowing users to account for out-of-tolerance conditions. In addition to this, the Fluke 7109A Portable Temperature Calibration Bath includes a 4:1 test uncertainty ratio (TUR) for critical applications. Moreover, in order to ensure precise measurements, the Fluke 7109A Portable Temperature Calibration Bath has been constructed in accordance with Fluke’s high metrological standards and is supplied with an NVLAP accredited calibration.

During calibrations, the user is able to monitor the bath fluid temperature, set-point temperature and heating status via the colour display. The date and time can also be viewed via this display. The user can easily see when the Fluke 7109A Portable Temperature Calibration Bath is suitably prepared to conduct measurements, as when the bath fluid has reached the set-point temperature, the ready indicator will change from amber to green. Furthermore, the Fluke 7109A Portable Temperature Calibration Bath includes a control indicator for when the fluid has reached the set-point.

Once the bath fluid has reached and/or exceeded 60°C, a Hot Warning indicator will illuminate. This feature is designed to protect the user’s safety. The inclusion of an overflow tube also works towards this end; it can be used to drain the bath fluid quickly and when used with the OPTIONAL overflow container may be used to drain excess fluid in order to prevent fluid spills.

Also working to prevent accidental spills is the Fluke 7109A Portable Temperature Calibration Bath’s sealed lid, it contains the bath fluid while the calibrator is being moved. This instrument can be easily transported as a result of its lightweight design (20kg/ 44 pounds) and the inclusion of two recessed handles at the base of the bath and one fixed, non-rotating bail handle at the top. This top handle allows the Fluke 7109A Portable Temperature Calibration Bath to be carried single-handedly.

The lightweight, portable and relatively compact design of the Fluke 7109A Portable Temperature Calibration Bath makes it suitable for use in hard-to-access places, such as crawl spaces. Adding to this instrument’s versatility-of-use is its stainless steel casing, which protects the instrument against the effects of harsh chemicals used to maintain clean rooms in accordance with US FDA and ISO standards. Its keyboard is also sealed against moisture ingress and its decals, keypads and feet are constructed from synthetic materials which prevent the accumulation of bacteria. All these features make the Fluke 7109A Portable Temperature Calibration Bath ideal for carrying out calibration applications in clean room environments.

The Fluke 7109A Portable Temperature Calibration Bath – Process Electronics Optional has been optimised for versatility, efficiency and practicality. It is ideal for accurately and quickly calibrating sanitary temperature sensors and RTDs in clean room environments.

 Fluke 7109A Portable Temperature Calibration Bath – Process Electronics Optional Key Features

  • Designed to calibrate multiple sanitary temperature sensors and RTDs simultaneously
  • Of particular use to facilities managers, production engineers and calibration technicians working in clean process industries
  • Particularly well suited to calibrating sanitary temperature sensors and RTDs used in pharmaceutical, biotechnological, and food production process manufacturing plants
  • Available in two models
  • The 7109A-P-256 - Fluke 7109A-P-256 Portable Temperature Calibration Bath with Process Electronics CAN be connected to an external reference probe
  • The 7109A-256 - Fluke 7109A-256 Portable Temperature Calibration Bath does NOT include process electronics and so CANNOT be connected to an external reference probe
  • Optimised to improve the speed with which calibrations can be performed, subsequently reducing the downtime of process manufacturing plants
  • Tank depth of 154mm
  • Tank opening of 122mm²
  • Calibrate a number of variously sized sensors simultaneously, with space for a reference thermometer
  • Adjustable probe fixture capable of holding up to four tri-clamp sensors securely in place during calibration
  • Quick, heating, cooling and stabilisation times
  • Stabilises in approximately 10 minutes
  • -25°C to 25°C in thirty-five minutes
  • 25°C to 140°C in fifty-five minutes
  • 140°C to 25°C in forty-five minutes
  • 25°C to -25°C in seventy-five minutes
  • Total temperature range of -25°C to 140°C
  • Suitable for calibrating temperature sensor applications performed in clean process manufacturing
  • Pharmaceutical bioreactors (-10°C to 100°C)
  • Steam-in-place process (122°C to 140°C)
  • Autoclave sterilisation (120°C to 135°C)
  • Food storage freezers (down to -25°C)
  • Food processing (0°C to 140°C)
  • A viable alternative to micro baths and dry-block calibrators
  • Display accuracy of ±0.1°C
  • Accuracy accounts for all sources of error including calibration uncertainty, stability, uniformity and repeatability
  • The user can account for out-of-tolerance conditions
  • 4:1 test uncertainty ratio (TUR) for critical applications
  • Constructed in accordance with Fluke’s high metrological standards
  • Supplied with an NVLAP accredited calibration
  • Monitor bath fluid temperatures, set-point temperatures and heating status via the colour display
  • Date and time are also viewable via the display
  • When the bath has reached the set-point temperature the ready indicator will change from amber to green
  • Control indicator for when the bath fluid has reached the set point
  • Once the bath fluid has reached and/or exceeded 60°C the Hot Warning indicator will illuminate
  • Overflow tube for quickly draining bath fluid
  • Overflow tube can be used with the OPTIONAL overflow container to prevent fluid spills
  • Sealed lid
  • Lightweight design: 20kg/ 44 pounds
  • Two recessed handles at the base of the bath
  • One fixed, non-rotating bail handle at the top of the instrument facilitates one-handed carrying
  • Ideal for use in hard-to-reach places such as crawl spaces
  • Stainless steel casing is resilient against chemicals used to maintain clean rooms in accordance with US FDA and ISO standards
  • The keyboard is sealed against moisture ingress
  • Decals, keypads and feet are constructed from synthetic materials which prevent the accumulation of bacteria
  • Suitable for applications in clean room environments
  • Optimised for versatility, efficiency and practicality
  • Ideal for accurately and quickly calibrating sanitary temperature sensors and RTDS in clean room environments

What’s Included?

  • Your Choice of Fluke 7109A Portable Temperature Calibration Bath With OR Without Process Electronics

Fluke 7109A Portable Calibration Bath – Process Electronics Optional Technical Specifications

The Fluke 7109A Portable Calibration Bath - Process Electronics Optional has a sister product, the Fluke 6109A Portable Calibration Bath - Process Electronics Optional, please find below the technical specifications for all four models included in this range. 

General Specifications
Size Height: 382 mm (15 in)
Width: 242 mm (9.5 in)
Depth: 400 mm (15.7 in)
Weight 6109A: 16 kg (35 lb)
7109A: 20 kg (44 lb)
Fluid volume 2.5 liters (0.66 gallons)
Fluid working area 75 mm x 75 mm (3 in x 3 in)
Maximum fluid depth 154 mm (6.1 in)
Factory calibration Traceable NVLAP-accredited calibration included
Temperature Specifications 
The temperature specifications describe the Absolute Instrumental Uncertainty at 95 % level of confidence (coverage factor k = 2) within one year from calibration. The specifications include environmental temperature effects from 13 °C to 33 °C.
Specifications 6109A 7109A
Range (at 25 °C ambient temperature) 35 °C to 250 °C –25 °C to 140 °C (–15 °C cover off)
Accuracy (maximum permissible error) 0.1 °C 0.1 °C
Display resolution 0.01 °, 0.001° 0.01 °, 0.001°
Stability 0.015 °C 0.01 °C
Typical uniformity 0.03 °C up to 200 °C 0.02 °C
0.04 °C above 200 °C
Repeatability 0.04 °C 0.04 °C
Typical heating time 35 °C to 100 °C: 25 minutes –25 °C to 25 °C: 35 minutes
100 °C to 250 °C: 45 minutes 25 °C to 140 °C: 55 minutes
Typical cooling time 250 °C to 100 °C: 35 minutes 140 °C to 25 °C: 45 minutes
100 °C to 35 °C: 55 minutes 25 °C to –25 °C: 75 minutes
Typical settling time 15 minutes 10 minutes
Process Input Module Specifications (-P models)
The Input Module specifications describe the Absolute Instrumental Uncertainty at 95 % level of confidence (coverage factor k = 2) within one year from calibration. The specifications include calibration uncertainty, linearity, repeatability, resolution, stability, and environmental temperature effects from 13 °C to 33 °C.
Function  Range  Accuracy (Maximum Permissible Error)
Reference input resistance 0 Ω to 42 Ω 0.0025 Ω
42 Ω to 400 Ω 0.006 %
Reference input temperature -25 °C to 250 °C -25 °C to 250 °C
Resistance sensing current 1 mA 8 %
DUT 4-wire resistance 0 Ω to 31 Ω 0.0025 Ω
31 Ω to 400 Ω 0.008%
DUT 3-wire resistance accuracy 0 Ω to 400 Ω 0.12 Ω
Thermocouple mV -10 mV to 100 mV 0.025 % + 0.01 mV
Reference junction temperature 0 °C to 40 °C 0.35 °C
Thermocouple Temperature -25 °C to 250 °C J: 0.44 °C 
K: 0.49 °C
T: 0.53 °C
E: 0.44 °C
N: 0.57 °C
M: 0.48 °C
L: 0.42 °C
U: 0.48 °C
0 °C to 250 °C R: 1.92 °C
S: 1.88 °C
C: 0.84 °C
D: 1.12 °C
G/W: 3.34 °C
mA range 0 mA to 22 mA 0.02 % + 0.002 mA
Loop power 24 V dc ± 6 V
Fluke 6109A & 7109A Portable Calibration Bath - Datasheet Datasheets Fluke 6109A & 7109A Portable Calibration Bath - User Manual Manuals & Guides Fluke 6109A & 7109A Portable Calibration Bath - Safety Information Notes & Other

Reviews

Additional Information
SKU Fluke 7109A
Manufacturer Part Code 4757572

Made to Order item: This item is made-to-order with a lead time once the order is placed. Once an order is placed it cannot be cancelled or returned unless the unit is found to be faulty.