All Fluke Calibration Products

Fluke 6532 Electronic Hydraulic Deadweight Tester – Extended Range

SKU
FLK-6532
Rating:
0%
(0)
Reward Points
:
41240
£41,240.40 £34,367.00
Made to Order
Free UK Delivery*
Advice & Support Call 01642 931329 or contact us
Price Match We won't be beaten, let us know
Fluke 6532 Electronic Hydraulic Deadweight Tester – Extended Range

The Fluke 6532 Electronic Hydraulic Deadweight Tester – Extended Range can be used to calibrate pressure sensing instruments such as transducers, transmitters, gauges and sensors as well as other pressure calibrators. This tester includes two high-precision quartz reference pressure transducers (with ranges from 7MPa/ 1000 psi to 200 MPA/ 30 000 psi) to which the reference pressure monitor can be configured, giving it an extended range and a percent of reading performance of 1% to 100% of device full scale.

The Fluke 6532 Electronic Hydraulic Deadweight Tester – Extended Range is available in three models with various pressure ranges; please see the table below for further details.

Product Code Product Name  Pressure Ranges High-precision Quartz Reference Pressure Transducers
6532-70M Fluke 6532-70M Electronic Hydraulic Deadweight Tester  Extended Range - 70MPa (10K psi) 0.7 to 70 MPa, 100 to 10,000 psi A70M/ A7M
6532-140M Fluke 6532-140M Electronic Hydraulic Deadweight Tester Extended Range - 140MPa (20K psi) 1.4 to 140 MPa, 200 to 20,000 psi A140M / A14M
6532-200M-B Fluke 6532-200M-B Electronic Hydraulic Deadweight Tester Extended Range - 200MPa (30K psi) 4 to 200 MPa, 600 to 30,000 psi A200M/ A20M

Like its sister product, this instrument includes features and functions designed to improve the efficiency and safety with which calibrations may be performed. One such feature is the AutoRange function, this function will tailor the tester’s measurement and safety settings to the instrument-under-investigation. Moreover, as the extended range model includes two high-precision quartz reference pressure transducers (Q-RPTs), the AutoRange feature will also ensure that the most appropriate Q-RPT is selected. A half-turn valve is used to protect the low range Q-RPT when the high-range module is in use. A visual and audible indicator alerts the user as to when the valve is correctly closed.

Also adding to the safety of calibration procedures is the over-pressure alarm, whilst the AutoTest function and Ready/Not Ready indicator add to the precision and efficiency of this process. The AutoTest function allows the user to program tests for the Fluke 6532 Electronic Hydraulic Deadweight Tester to perform automatically. The Ready/ Not Ready indicator alerts the user as to when it is suitable to take measurements.

Data acquired using this tester can be saved to the onboard memory. Measurements may also be transferred to a computer featuring Fluke’s COMPASS Pressure Software (NOT included) via the Fluke 6532 Electronic Hydraulic Deadweight Tester’s RS-232 interface, allowing the user to view data in real-time and create reports. 

Additionally, the RS-232 interface may be used to operate the Fluke 6532 Electronic Hydraulic Deadweight Tester’s reference pressure monitor remotely via a computer and using ASCII character command strings. Alternatively, the reference pressure monitor can be configured via the tester’s front panel display and keyboard or using an OPTIONAL foot pedal which also facilitates the user’s ability to perform hands-free data collection while the instrument performs AutoTest sequences.

These features and functions make the Fluke 6532 Electronic Hydraulic Deadweight Tester a viable, practical, easy-to-use alternative to traditional deadweight testers. It has many advantages over traditional testers including:

  • It can be used to perform calibrations in a variety of measurement units
  • It is suitable for calibrating analogue pressure gauges as minimal pressure increments are not restricted by the smallest masses available. This allows the user to set, test and measure precise nominal pressure values.
  • Not susceptible to significant errors caused by vibrations
  • Changing of the piston and cylinder is not required
  • Variables such as gravity and temperature do not need to be accounted for, allowing accurate pressure values to be read in real-time
  • Weight masses are not required

Furthermore, the Fluke 6532 Electronic Hydraulic Deadweight Tester can be used with a variety of fluids including Sebacate calibration fluid, mineral oil and water.  It is also able to match the accuracy of traditional deadweight testers as it has a total one-year measurement uncertainty of ±0.02% (±0.025% for two years).

It is equipped with a low torque variable volume which allows the user to create and make fine adjustments to hydraulic pressures up to 200MPa. This is a simple-to-use module that requires minimal physical effort. In addition to this, a vacuum fill kit is supplied with this tester allowing the user to fill the system with the fluid of his/her choice. Its integrated priming-system also ensures that the Fluke 6532 Electronic Hydraulic Deadweight Tester can be filled with the required fluid; it can also be used to purge the system of unwanted air facilitating the accurate creation of hydraulic pressures.

Additionally, the Fluke 6532 Electronic Hydraulic Deadweight Tester is supplied with a selection of test station adapters including 1/8 in, 1/4 in, 3/8 in and 1/2 in NPT, 1/8 in, 1/4 in, 3/8 in and 1/2 in BSP, M20 x 1.5 and M14 x 1.5. These adapters add to the Fluke 6532’s practicality and ease-of-use as they facilitate the user’s ability to connected instruments-under-investigation to the tester without the use of PTFE tape and/or wrenches. The Fluke 6532 Electronic Hydraulic Deadweight Tester is NOT supplied with a rechargeable battery; however, it can be powered using one such battery pack allowing the user to adapt the instrument to the application.

The versatility, adaptability and resilience of the Fluke 6532 Electronic Hydraulic Deadweight Tester – Extended Range makes it suitable for applications in a variety of environments including metrology and calibration labs, production floors, and in the field.

Fluke 6532 Electronic Hydraulic Deadweight Tester – Extended Range Key Features

  • Calibrate pressure sensing instruments such as transducers, transmitters, analogue gauges and sensors as well as other pressure calibrators
  • Includes 2 high-precision quartz reference pressure transducers (ranges from 7MPa/ 1000 psi to 200 MPA/ 30 000 psi)
  • Reference pressure monitor can be configured to either transducer facilitating its extended range and percent reading performance of 1% to 100% of the device’s full scale
  • Available in three models with various pressure ranges
  • AutoRange tailors the measurement and safety settings to the instrument-under-investigation
  • AutoRange ensures that the most appropriate high-precision quartz reference pressure transducer (Q-RPT) is selected
  • Half-turn valve protects the low range Q-PRT when the high range Q-PRT is in use
  • Visual and audible indicator alerts the user as to when the valve is correctly shut off
  • Over-pressure alarm
  • AutoTest function
  • Ready/ Not ready indicator
  • Save data to the onboard memory
  • Measurements can be transferred to a computer including Fluke’s COMPASS Pressure Software (NOT included) using the RS-232 interface
  • The RS-232 interface can be used to operate the tester remotely using a computer and ASCII character command strings
  • Reference pressure monitor can be configured via the tester’s front panel display and keyboard and/or via the OPTIONAL foot pedal
  • The OPTIONAL foot pedal can be used to perform hands-free data collection when the instrument is performing AutoTest sequences
  • Viable, practical, easy-to-use alternative to traditional deadweight testers
  • It can be used to perform calibrations in a variety of measurement units
  • It is suitable for calibrating analogue pressure gauges as minimal pressure increments are not restricted by the smallest masses available. This allows the user to set, test and measure precise nominal pressure values.
  • Not susceptible to significant errors caused by vibrations
  • Changing of the piston and cylinder is not required
  • Variables such as gravity and temperature do not need to be accounted for, allowing accurate pressure values to be read in real-time
  • Weight masses are not required
  • Can be used with a variety of fluids including Sebacate calibration fluid, mineral oil and water
  • One year measurement uncertainty of ±0.02% (±0.025% for two years)
  • Low torque variable volume can be used to create and make fine adjustments to hydraulic pressures up to 200MPa
  • Simple-to-use, requiring minimal physical effort
  • Supplied with a vacuum fill kit
  • Integrated priming system for filling the tester with the required fluid and purging it of unwanted air
  • Supplied with test station adapters including 1/8 in, 1/4 in, 3/8 in and 1/2 in NPT, 1/8 in, 1/4 in, 3/8 in and 1/2 in BSP, M20 x 1.5 and M14 x 1.5
  • PTFE tape and/or wrenches are not required when attaching instruments-under-investigation
  • Can be powered using a rechargeable battery (NOT included)
  • Suitable for applications in metrology and calibration labs, on production floors, and in the field

What’s Included?

  • Your Choice of Fluke 6532 Electronic Hydraulic Deadweight Tester – Extended Range
  • Power Supply
  • Operating Manual
  • Vacuum Liquid Fill Kit
  • Test Station Mount Fitting
  • NPT adapters: 1/8 in, 1/4 in, 3/8 in and 1/2 in
  • BSP adapters: 1/8 in, 1/4 in, 3/8 in and 1/2 in
  • Metric adapters: M20 x 1.5 and M14 x 1.5

Fluke 6532 Electronic Hydraulic Deadweight Tester – Extended Range Technical Specifications

General Specifications 
Power Requirements
To RPM4-E-DWT 12 V dc 1.2 A
To AC to DC power supply 100 V ac to 240 V ac, 50/60 Hz
Temperature Range
Storage - 20 °C to 70 °C
Operating 10 °C to 40 °C
Relative Humidity 
Storage 0 % to 100 %
Operating 0 % to 70 %
Weight
1 Q-RPT 12 kg (26 lb) approximate
2 Q-RPT 14 kg (30 lb) approximate
Dimensions
E-DWT footprint 41.4 cm W x 37.1 cm D (16.3 in x 14.6 in)
E-DWT height 26.9 cm (10.6 in), 33.6 cm (13.2 in) to max variable volume handle height
Pressure Range  Up to 200 MPa (30k psi), depending on configuration
Operating Medium  All 6531 and 6532 E-DWT Kits are shipped dry, standard preparation. Can be filled with di-ethyl-hexyl sebacate, silicon oils, propylene glycol, fully fluorinated liquids, partially fluorinated liquids, isopropyl alcohol and distilled water or mineral oil.
Reservoir Capacity  300 cc (18 in3)
Variable Volume Displacement  3 cc (0.18 in3), 200 MPa (30,000 psi) maximum
Filling and Priming Pump Displacement  3.7 cc (0.23 in3)
TEST Pressure Connection  DH500 female, 200 MPa (30k psi) maximum working pressure. Adapters included for 1/8 in, 1/4 in, 3/8 in and 1/2 in NPT, 1/8 in, 1/4 in, 3/8 in and 1/2 in BSP, M20 x 1.5 and M14 x 1.5. Adapter maximum working pressure is 140 MPa (20k psi). Note: DH500 is a gland and collar type fitting for 6 mm (1/4 in) coned and left hand threaded tubes equivalent to AE F250C, HIP HF4, 9/16-18 UNF, etc.
Pressure Limits
Maximum Working Pressure  Range of RPM4-E-DWT monitor’s Hi Q-RPT
Maximum Priming Pump Pressure  700 kPa (100 psi)
Maximum Working Pressure  with Lo Q-RPT selected: Range of RPM4-E-DWT monitor’s Lo Q-RPT
Communication Ports  RS-232 (COM1, COM2)
Pressure Measurement 
Warm Up Time  15 minute temperature stabilization recommended from cold power up
Normal Operating Temperature Range  10 °C to 40 °C (50 °F to 104 °F)
Resolution  Default: 0.01 % of active range
User adjustable to 1 ppm of Q-RPT maximum or 10 ppm of active AutoRange, whichever is larger
Precision1
200 MPa (30,000 psi) ranges:  ± 0.018 % of reading or 0.0036 % of Q-RPT span, whichever is greater
 
All other ranges:  ± 0.018 % of reading or 0.0018 % of Q-RPT span, whichever is greater
Predicted Stability 2
One year ± 0.0075 % of reading
Two years ± 0.015 % of reading
Measurement Uncertainty 3
One year
200 MPa (30,000 psi) ranges:  ± 0.02 % of reading or 0.004 % of Q-RPT span, whichever is greater
 
All other ranges:  ± 0.02 % of reading or 0.002 % of Q-RPT span, whichever is greater
Two years
200 MPa (30,000 psi) ranges:  ± 0.025 % of reading or 0.005 % of Q-RPT span, whichever is greater
 
All other ranges:  ± 0.025 % of reading or 0.0025 % of Q-RPT span, whichever is greater
Notes 1. Combined linearity, hysteresis, and repeatability. Precision does not include stability or calibration reference uncertainty.
2. Predicted Q-RPT measurement stability limit (k=2) assuming regular use of AutoZero function and short term stability between rezeroing.
3. Maximum deviation of the Q-RPT indication from the true value of applied pressure including precision, predicted stability with rezeroing, temperature effect from 10 ºC to 40 ºC and calibration uncertainty (assumes calibration reference uncertainty of ±0.005 % of reading, k=2), combined and expanded (k=2) following the ISO “Guide to the Expression of Uncertainty in Measurement.
Fluke 6531 and 6532 Electronic Hydraulic Deadweight Tester - Datasheet Datasheets Fluke 6531 and 6532 Electronic Hydraulic Deadweight Tester - User Guide Manuals & Guides Fluke 6531 and 6532 Electronic Hydraulic Deadweight Tester - Fill Kit Procedure Manuals & Guides Fluke Electronic Hydraulic Deadweight Tester - Brochure Brochures & Catalogues

Reviews

Additional Information
SKU FLK-6532
Manufacturer Part Code 4183689

Made to Order item: This item is made-to-order with a lead time once the order is placed. Once an order is placed it cannot be cancelled or returned unless the unit is found to be faulty.