Fluke 5606 Full Immersion PRT Probes - Choice of Termination

Buy a Fluke Get One Free (Spend £150+)
All Fluke Calibration Products
  • -200 °C to 160 °C temperature range
  • Unique probe seal prevents ingress of moisture
  • Can withstand full PRT temperature range
SKU
5606-PROBE

Read More

View All Thermocouples & Thermal Probes

The PRTs are designed to perform in extreme environments where both the transition junction and the lead wires are required to withstand temperatures covering the entire operating range of the probe. Termination Key.

The probes are just two inches (50 mm) in length with a sheath diameter of 1/8 inch (3.1 mm). Since it can be fully immersed over its entire temperature range, you don't have to worry about calculating minimum immersion depth - immerse the entire probe, transition junction, and lead wires, in either non-corrosive liquids or dry mediums ranging from -200 °C to 160 °C. Termination ranges available from A to S & CLEN A to CLEN P.

Product Ranges

  • Fluke 5606-50-A Immersion Probe PRT, -200° to 160°, 50mm
  • Fluke 5606-50-B Immersion Probe PRT, -200° to 160°, 50mm
  • Fluke 5606-50-D Immersion Probe PRT, -200° to 160°, 50mm
  • Fluke 5606-50-G Immersion Probe PRT, -200° to 160°, 50mm
  • Fluke 5606-50-J Immersion Probe PRT, -200° to 160°, 50mm
  • Fluke 5606-50-L Immersion Probe PRT, -200° to 160°, 50mm
  • Fluke 5606-50-M Immersion Probe PRT, -200° to 160°, 50mm
  • Fluke 5606-50-P Immersion Probe PRT, -200° to 160°, 50mm
  • Fluke 5606-50-S Immersion Probe PRT, -200° to 160°, 50mm
  • Fluke 5606-CLEN-A Immersion Probe PRT, -200° to 160°, 50mm
  • Fluke 5606-CLEN-B Immersion Probe PRT, -200° to 160°, 50mm
  • Fluke 5606-CLEN-D Immersion Probe PRT, -200° to 160°, 50mm
  • Fluke 5606-CLEN-G Immersion Probe PRT, -200° to 160°, 50mm
  • Fluke 5606-CLEN-J Immersion Probe PRT, -200° to 160°, 50mm
  • Fluke 5606-CLEN-L Immersion Probe PRT, -200° to 160°, 50mm
  • Fluke 5606-CLEN-M Immersion Probe PRT, -200° to 160°, 50mm
  • Fluke 5606-CLEN-P Immersion Probe PRT, -200° to 160°, 50mm
  • Termination Key:
  • A (INFO-CON for 914X)
  • B (Bare wire)
  • D (5-pin DIN for Tweener Thermometers)
  • G (Gold pins)
  • J (Banana plugs)
  • L (Mini spade lugs)
  • M (Mini banana plugs)
  • P (INFO-CON for 1523 or 1524)
  • S (Spade lugs)
£572.00
£686.40 inc vat
Free Delivery*
1 Option in Stock: Available Next Working Day*
Important Notice
This item is made-to-order exclusively for you once your order is placed. As a result, it is not eligible for cancellation or return under our standard policy. Your statutory rights remain unaffected.
Buy a Fluke Get One Free (Spend £150+) Find Out More
572 Reward Points 60 Days Return

Ask An Expert
Price Match

Offers

Buy a Fluke Get One Free (Spend £150+)

Spend £150+ (Ex VAT) on any qualified Fluke or Beha-Amprobe product(s) and claim a free tool of your choice from the list at Fluke Promotion. Valid February 17 2025 - July 31 2025.

Claims are made direct to Fluke. Terms and conditions apply.

Technical Information
Specification
Fluke 5606 Specifications
Temperature range –200 °C to 160 °C.
Nominal resistance at 0.01 °C 100 Ω ± 0.1 Ω.
Temperature coefficient 0.00385 Ω/Ω/°C.
Accuracy[1] ± 0.04 °C at 0.01 °C
± 0.06 °C at 160 °C.
Short-term repeatability[2] ± 0.03 °C at 0.01 °C
± 0.04 °C at 160 °C.
Drift[3] ± 0.03 °C at 0.01 °C
± 0.04 °C at 160 °C.
Hysteresis ± 0.015 °C.
Sheath length 50 mm ± 5 mm, (2 in ± 0.2 in).
Sheath diameter 3.1 mm ± 0.1 mm (1/8 in ± 0.004 in).
Sheath material 316 SST.
Transition junction temperature range[4] –200 °C to 160 °C.
Sensor length 30 mm ± 3mm (1.2 in ±0.1 in).
Sensor location 3 mm ± 1 mm from tip (1.2 in ± 0.04 in).
Minimum insulation resistance 20 MΩ at 23 °C.
Minimum immersion length Full immersion.
Maximum immersion depth in liquid medium Full immersion.
Response time[5] 12 seconds typical.
Self-heating (in 0 °C bath) ± 0.003 °C.
Lead-wire cable type Enameled copper wire.
Lead-wire length 2.4 meters (8 ft).
Lead-wire temperature range 160 °C.
  • [1] Includes calibration accuracy and 100 hr drift (k = 2).
  • [2] Three thermal cycles from min to max temp, including hysteresis, 95 % confidence (k = 2).
  • [3] After 100 hours at max temp, 95 % confidence (k = 2).
  • [4] Temperatures outside this range will cause irreparable damage.
  • [5] Per ASTM E 644.
Document Downloads
Fluke 5606/5607 Full Immersion PRT Probes User Manual Manual/Guide
Additional Information
SKU
5606-PROBE

Customer Reviews

 
Fluke 5606 Full Immersion PRT Probes - Choice of Termination
£572.00
£686.40 inc vat
£572.00
£686.40 inc vat