Fluke 9132-256 Portable IR Calibrator – Temperature Range: 50 to 500°C

The Fluke 9132-256 Portable IR Calibrator can be used to calibrate above ambient, handheld pyrometers, including non-contact infrared thermometers. To this end, it has a temperature range of 50 to 500°C.

The Fluke 9132-256 Portable IR Calibrator has an accuracy of ±0.5°C to ±0.8°C, depending on the temperature generated. This ensures that infrared thermometers can be calibrated accurately, as does the inclusion of a 57mm-diameter blackbody target. This target has an emissivity of 0.95 (±0.02 %) and can be accurately calibrated via the RTD-reference well located behind the target. Its large target area ensures that the field-of-view of a majority of non-contact infrared thermometers are accommodated for, thereby increasing this instrument’s scope-for-use.

The temperature of the blackbody target can be precisely controlled and may be increased or decreased in set-point increments of 0.1°C. The Fluke 9132-256 Portable IR Calibrator is able to offer a stability of ±0.1°C and takes only a short while to heat or cool to the desired temperature:

  • Heating time: from 50°C to 500°C in thirty minutes
  • Cooling time: from 500°C to 100°C in thirty minutes

In addition to its accuracy and efficiency, this compact, ergonomic and portable instrument with a hand strap is also easy-to-use:

1.)    Set the desired temperature via the front panel control buttons

2.)    Wait for the Fluke 9132-256 Portable IR Calibrator to heat/cool to the desired temperature and stabilise

3.)    Point the non-contact instrument-under-investigation at the blackbody target

4.)    Compare the reading on the pyrometer to the reading on the Fluke 9132-256 Portable IR Calibrator’s display

5.)    Record any difference in the readings

This instrument can be adjusted to suit the user’s needs and to this end includes an eight set-point memory and option to display readings in °C or °F. Its RS-232 interface facilitates the user’s ability to configure the instrument using his/her PC and the included Fluke Model 9930 Interface-It Software. 

The Fluke 9132-256 Portable IR Calibrator is a simple-to-use, practical, accurate and reliable temperature calibrator, ideal for checking a variety of pyrometers, especially non-contact infrared thermometers.

Fluke 9132-256 Portable IR Calibrator Key Features

  • Calibrate above-ambient IR pyrometers
  • Ideal for calibrating non-contact infrared thermometers
  • Temperature range: 50°C to 500°C
  • Accuracy: ±0.5°C to ±0.8°C (depending on the temperature generated)
  • 57mm-diameter blackbody target
  • Target emissivity: 0.95 (±0.02%)
  • The inclusion of an RTD-reference well behind the blackbody target ensures that it can be accurately calibrated
  • Large target accommodates the FOVs of most non-contact infrared thermometers
  • The temperature of the blackbody target can be altered in 0.1°C set-point increments
  • Stability: ±0.1°C
  • Heating time: from 50°C to 500°C in thirty minutes
  • Cooling time: from 500°C to 100°C in thirty minutes
  • Compact, ergonomic and portable design
  • The desired temperature can be set via the front panel controls
  • Once the temperature has been reached and is stable, point the instrument-under-investigation at the blackbody target
  • Compare the reading on the pyrometer to the reading on the display
  • Eight set-point memory
  • Can display readings in either °C or °F
  • RS-232 interface capability
  • Supplied with Fluke’s Model 9930 Interface-It Software
  • Software and interface can be used to configure the instrument via the user’s PC
  • Hand strap
  • Simple-to-use, practical, accurate and reliable temperature calibrator
  • Ideal for checking a variety of IR pyrometers

What’s Included?

  • Fluke 9132-256 Portable IR Calibrator – Temperature Range: 50 to 500°C
  • Fluke Interface-it Software

Fluke 9132-256 Portable IR Calibrator Technical Specifications 

The Fluke 9132-256 Portable IR Calibrator is part of Fluke's series of 913X Portable IR Calibrators; please find below the technical specifications for both the models included in this series.

Specifications  9133 9132
Temperature Range –30 °C to 150 °C at 23 °C ambient
(–22 °F to 302 °F at 73 °F ambient)
50 °C to 500 °C
(122°F to 932°F)
Accuracy ± 0.4 °C (± 0.72 °F) ± 0.5 °C at 100 °C
(± 0.9°F at 212°F)
± 0.8 °C at 500 °C
(± 1.4 °F at 932 °F)
Stability ± 0.1 °C (± 0.18 °F) ± 0.1°C at 100°C
(± 0.18°F at 212°F)
± 0.3°C at 500°C
(± 0.54°F at 932°F)
Target Size 57 mm (2.25 in)
Target Emissivity 0.95 (± 0.02 from 8 to 14 µm)
Resolution 0.1 °
Heating Time 15 minutes (25 °C to 150 °C) 30 minutes (50 °C to 500 °C)
Cooling Time 15 minutes (25 °C to –20 °C) 30 minutes (500 °C to 100 °C)
Computer Interface RS-232 interface
Power 115 V ac (± 10 %), 1.5 A, or
230 V ac (± 10 %), 1.0 A,
switchable, 50/60 Hz, 200 W
115 V ac (± 10 %), 3 A or
230 V ac (± 10 %), 1.5 A,
switchable, 50/60 Hz, 340 W
Size (HxWxD) 152 x 286 x 267 mm
(6 x 11.25 x 10.5 in)
102 x 152 x 178 mm
(4 x 6 x 7 in )
Weight 4.6 kg (10 lb) 1.8 kg (4 lb)
NIST-Traceable
Contact Calibration
Data at –30°C, 0°C, 25°C, 75°C, 100°C, 125°C, and 150°C Data at 50°C, 100°C, 200°C, 250°C, 300°C, 400°C, and 500°C
Fluke 9132-256 Portable IR Calibrator - User Guide Supplement Manuals & Guides Fluke 9132-256 Portable IR Calibrator - User Guide Manuals & Guides Fluke's Guide to Infrared Temperature Calibration Manuals & Guides