Designed for solar photovoltaic (PV) installation technicians and maintenance professionals working in high voltage DC environments, the Fluke 393FC Solar Clamp Meter & Pomona MC4 Test Leads Kit includes:
- Fluke 393FC Solar Clamp Meter with Accessories
- Fluke Pomona PVLEAD1 MC4 Solar Test Leads
- Fluke Pomona PVLEAD3 MC4 Solar Test Leads
Fluke 393FC True-RMS Solar Clamp Meter Overview
Ideal for checking solar arrays, wind power equipment, electric railways, data centres, and battery banks, the Fluke 393FC True-RMS Solar Clamp Meter is the only clamp meter designed to measure 1500V DC systems. Via its thin clamp, which enables access to cables in crowded combiner boxes, it can measure the following parameters:
- DC voltage: up to 1500V
- AC voltage: up to 1000V
- AC/DC current: up to 999.9A
The supplied iFlex flexible current probe both extends the Fluke 393FC True-RMS Solar Clamp Meter's AC range up to 2500A and facilitates access to tight spaces. The Fluke 393FC True-RMS Solar Clamp Meter can also be used to measure DC power (kVA) and includes audio polarity and visual continuity indicators. Fluke Connect technology allows you to wirelessly log results to the Fluke Connect App. From the app, data may be analysed, shared, and/or used to create reports.
Finally, the Fluke 393FC True-RMS Solar Clamp Meter is IP54 certified and features a CAT III 1500V safety rating. It is ideal for technicians working inside or outside high-voltage DC environments.
For more information regarding the Fluke 393FC True-RMS Solar Clamp Meter, please click here.
Fluke Pomona PVLEAD1 MC4 Test Leads Overview
The Fluke Pomona PVLEAD1 MC4 Test Leads can be used to connect the Fluke 393FC True-RMS Solar Clamp Meter to PV panels, modules, and systems ensuring safe current and voltage measurements. Ideal for regular testing, measuring, and troubleshooting of solar PV panels, the Fluke Pomona MC4 Test Lead is compliant with CAT III 1000V/ CAT IV 600V, and 20A ratings in accordance with IEC/EN 61010-031.
Fluke Pomona PVLEAD3 MC4 Solar Test Leads Overview
Specifically designed for use with solar clamp meters that accept 4mm banana plugs, such as the Fluke 393FC Solar Clamp Meter, the Fluke Pomona PVLEAD3 MC4 Solar Test Leads facilitate a connection between the solar panel and inverter enabling troubleshooting and maintenance inspections. They ensure that you can take safe DC power measurements on PV modules and systems without interrupting power generation. The Fluke Pomona PVLEAD3 MC4 Solar Test Leads are CAT III 1000V/ CAT IV 600V safety rated and comply with 20A ratings in accordance to IEC/EN 61010-031.
What’s Included?
- Fluke 393FC True-RMS Solar Clamp Meter
- Test Leads (CAT III 1500V, right-angle plugs, safety caps)
- iFlex 18-inch Flexible Current Probe
- TPAK Magnetic Hanging Strap
- Premium Carry Case
- Pomona PVLEAD1 MC4 to 4mm Test Lead Set
- Pomona PVLEAD3 MC4 Solar Clamp Test Lead Set
Fluke 393 FC CAT III 1500V True-RMS Clamp Meter with iFlex Technical Specifications
General | |
Maximum voltage between any Terminal and Earth Ground | |
AC | 1000 V |
DC | 1500 V |
Batteries | 2 AA IEC LR6 alkaline |
Display | Dual display with backlight |
Automatic Power Off | 20 minutes |
Electrical | |
Accuracy | Accuracy is specified for 1 year after calibration, at operating temperatures of 18 °C to 28 °C, relative humidity at 0 % to 75 %. Accuracy specifications take the form of: ±([% of Reading] + [Number of Least Significant Digits]). |
Temperature Coefficients | Add 0.1 x specified accuracy for each °C > 28 °C or < 18 °C |
AC Current: Jaw | |
Range | 999.9 A |
Resolution | 0.1 A |
Accuracy | 2 % + 5 digits (10 Hz to 100 Hz) |
2.5 % + 5 digits (100 Hz to 500 Hz) | |
Crest Factor (50/60 Hz) | 2.5 @600.0 A |
3.0 @500.0 A | |
1.42 @999.9 A | |
Add 2 % for C.F. >2 | |
AC Current: Flexible Current Probe | |
Range | 999.9 A |
2500 A | |
Resolution | 0.1 A (≤999.9 A) |
1 A (≤2500 A) | |
Accuracy | 3 % RD + 5 digits (10 Hz to 500 Hz) |
Crest Factor (50/60Hz) | 2.5 @1400 A |
3.0 @1100 A | |
1.42@2500 A | |
Add 2 % for C.F. >2 | |
DC Current | |
Range | 999.9 A |
Resolution | 0.1 A |
Accuracy | 2 % RD + 5 digits[1] |
Note | [1] When using the ZERO (B) function to compensate for offsets. |
AC Voltage | |
Range | 600.0 V |
1000 V | |
Resolution | 0.1 V (≤600.0 V) |
1 V (≤1000 V) | |
Accuracy | 1 % RD + 5 digits (20 Hz to 500 Hz) |
DC Voltage | |
Range | 600.0 V |
1500 V | |
Resolution | 0.1 V (≤600.0 V) |
1 V (≤1500 V) | |
Accuracy | 1 % RD + 5 digits |
mV DC | |
Range | 500.0 mV |
Resolution | 0.1 mV |
Accuracy | 1 % RD + 5 digits |
Amps Frequency: Jaw | |
Range | 5.0 Hz to 500.0 Hz |
Resolution | 0.1 Hz |
Accuracy | 0.5 % RD + 5 digits |
Trigger Level | 5 Hz to 10 Hz, ≥10 A |
10 Hz to 100 Hz, ≥5 A | |
100 Hz to 500 Hz, ≥10 A | |
Amps Frequency: Flexible Current Probe | |
Range | 5.0 Hz to 500.0 Hz |
Resolution | 0.1 Hz |
Accuracy | 0.5 % RD + 5 digits |
Trigger Level | 5 Hz to 20 Hz, ≥25 A |
20 Hz to 100 Hz, ≥20 A | |
100 Hz to 500 Hz, ≥25 A | |
Voltage Frequency | |
Range | 5.0 Hz to 500.0 Hz |
Resolution | 0.1 Hz |
Accuracy | 0.5 % RD + 5 digits |
Trigger Level | 5 Hz to 20 Hz, ≥5 V |
20 Hz to 100 Hz, ≥5 V | |
100 Hz to 500 Hz, ≥10 V | |
DC Power | |
Range | 600.0 kVA (600.0 V dc range) |
1500 kVA (1500 V dc range) | |
Resolution | 0.1 kVA |
1 kVA | |
Accuracy | 2 % RD + 2.0 kVA |
2 % RD + 20 kVA | |
Resistance | |
Range | 600.0 Ω |
6000 Ω | |
60.00 kΩ | |
Resolution | 0.1 Ω (≤600.0 Ω) |
1 Ω (≤6000 Ω) | |
0.01 kΩ (≤60.00 kΩ) | |
Accuracy | 1 % RD + 5 digits |
Capacitance | |
Range | 100.0 μF |
1000 μF | |
Resolution | 0.1 μF (≤100.0 μF) |
1 μF (≤1000 μF) | |
Accuracy | 1 % RD + 5 digits |
Inrush Trigger Level | 5 A |
Mechanical | |
Size (L x W x H) | 281 mm x 84 mm x 49 mm |
Weight (with batteries) | 520 g |
Jaw Opening | 34 mm |
Flexible Current Probe Diameter | 7.5 mm |
Flexible Current Probe Cable Length (head to electronics connector) | 1.8 m |
Environmental | |
Operating Temperature | -10 °C to 50 °C |
Storage Temperature | -40 °C to 60 °C |
Operating Humidity | Non condensing (<10°C) |
≤90 % RH (at 10 °C to 30 °C) | |
≤75 % RH (at 30 °C to 40 °C) | |
≤45 % RH (at 40 °C to 50 °C) | |
Operating Altitude | 2000 m |
Storage Altitude | 12 000 m |
Ingress Protection (IP) Rating | IEC 60529: IP54 non-operating |
Electromagnetic Compatibility (EMC) | |
International | IEC 61326-1: Portable, Electromagnetic Environment, IEC 61326-2-2 CISPR 11: Group 1, Class A |
Group 1: Equipment has intentionally generated and/or uses conductively-coupled radio frequency energy that is necessary for the internal function of the equipment itself. | |
Class A: Equipment is suitable for use in all establishments other than domestic and those directly connected to a low-voltage power supply network that supplies buildings used for domestic purposes. There may be potential difficulties in ensuring electromagnetic compatibility in other environments due to conducted and radiated disturbances. | |
Caution: This equipment is not intended for use in residential environments and may not provide adequate protection to radio reception in such environments. | |
Korea (KCC) | Class A equipment (Industrial Broadcast & Communications Equipment) |
Class A: Equipment meets requirements for industrial electromagnetic wave equipment and the seller or user should take notice of it. This equipment is intended for use in business environments and not to be used in homes. | |
USA (FCC) | 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103. |
Safety | |
General | IEC 61010-1, Pollution Degree 2 |
Measurement | IEC 61010-2-032: CAT III 1500 V / CAT IV 600 V |
IEC 61010-2-033: CAT III 1500 V / CAT IV 600 V | |
Wireless Radio | |
Radiofrequency certification | FCC ID: T68-FBLE, IC: 6627A-FBLE |
Wireless Radio Frequency Range | 2400 MHz to 2483.5 MHz |
Output Power | <100 mW |
SIMPLIFIED EU DECLARATION OF CONFORMITY | Hereby, Fluke declares that the radio equipment contained in this Product is in compliance with Directive 2014/53/EU. |
Reviews
SKU | 5337394 |
---|---|
Manufacturer Part Code | 5337394 |
Country of Origin | China |