Use Fluke's 368 FC leakage current clamp meter to detect, record and compare leakage current over time, helping you prevent unplanned downtime and to identify intermittent GFCI and RCD trips, all without taking equipment offline!
The Fluke 368 is equipped with fully shielded, 40mm diameter jaws best suited for use with larger conductors. Thanks to the jaws' shielding, the clamp is excellent for detecting very small leakage signals and also reduces the effects electromagnetic interference can have on measurement readings.
With highest resolution of 1μA and highest measurement range of up to 60A, the Fluke 368 FC is ideal for use in a wide variety of applications. This clamp meter is also true RMS - it's designed to ensure accuracy even when you're measuring on complex, non-sinusodial waveforms so no matter where you're using the Fluke 368 FC, you'll always get accurate results you can rely on.
The 'FC' in the 368 FC's product name refers to this clamp meter's built-in Fluke Connect technology. Fluke Connect allows the 368 FC to wirelessly interface with smartphones or tablets running the Fluke Connect app, allowing you to view results externally, share them with others, create reports, make graphs and much, much more!
With Fluke Connect, you can:
Measurement Function | AC (alternating current) |
AC Current Range(s) | 3mA, 30mA, 300mA, 3A, 30A, 60A |
mA/A: manual selection 3mA/30mA/300mA: automatic selection 3A/30A/60A: automatic selection |
|
Range/Resolution | 3mA/0.001mA |
30mA/0.01mA | |
300mA/0.1mA | |
3A/0.001A | |
30A/0.01A | |
60A/0.1A | |
Accuracy - Filter Activated (40 to 70Hz), Filter Off (40 to 1kHz) | 3mA to 30A: ±1% + 5 digits |
60A: 2% + 5 digits | |
Frequency | 40Hz to 1kHz |
Crest Factor | 3 |
Additional Specifications | |
---|---|
Display (LCD) | Digital readout: 3300 count |
Display Refresh Rate | 4 times/sec |
Maximum Conductor Diameter | 40mm |
Dimensions | 234 x 101 x 46mm |
Weight | 500g |
Battery | 2AA, IEC LR6, NEDA 15A, alkaline |
Battery Life | More than 150 hours (without backlight and spotlight) |
Automatic Shutdown | After 15 minutes of inactivity |
General Safety | IEC 61010-1: Pollution Degree 2 |
Measurement Safety | IEC 61010-2-032: CAT III 600V, CAT IV 300V |
Operating Temperature | -10 to +50°C |
Storage Temperature | -40 to +60°C |
Operating Humidity | Non-condensing (<10°C) |
90% relative humidity (10 to 30°C) | |
75% relative humidity (30 to 40°C) | |
45% relative humidity (40 to 50°C) | |
Protection Class | IEC 61557-13: Class 2, ≤30A/m |