All Fluke Products

Fluke 355 AC/DC True RMS Clamp Meter

SKU
FLUCM8
Rating:
0%
(0)
Reward Points
:
695
£834.00 £695.00
Free UK Delivery*
Advice & Support Call 01642 931329 or contact us
Price Match We won't be beaten, let us know
Fluke 355 AC DC True RMS Clamp Meter - Kit

An upgraded version of Fluke's 353 clamp meter, this instrument includes extra measurement functions that aren't found on the lesser model.

The Fluke 355 features incredibly large 58mm jaws, making this clamp suitable for attachment to larger or multiple conductors at the same time. Once attached it allows the user to carry out measurements of current (both AC/DC) to a high threshold of 2000A.

Unique functions exclusive to this model include the ability to carry out high voltage measurements to 1000V true-rms, resistance measurements to 400kΩ and a continuity beeper.

In order to ensure measurements are as accurate as possible the Fluke 355 also includes a low-pass filter which smooths out the effects of noisy loads. This clamp meter also includes a backlit LCD screen, MIN/MAX and AVG measurement functions and the ability to store testing data on screen temporarily using the data hold function.

Fluke 355 AC/DC True RMS Clamp Meter Key Features

  • Large size 58mm jaws
  • AC/DC current measurements to 2000A
  • 1000V true RMS voltage measurements
  • Resistance measurements to 400kΩ
  • Continuity beeper
  • CAT IV 600V and CAT III 1000V safety rating
  • Frequency measurements
  • Low pass filter stops effects of noise
  • MIN/MAX/AVG

Full List of Products Included

  • Fluke 355 Clamp Meter
  • C43 Soft Carrying Case
  • 6 x AA Batteries
  • TL224 1.5m Silicone Rubber Test Leads
  • TP2 Test Probes
  • AC285 Alligator Clips
  • User Manual
  • 3 Year Warranty

Fluke 355 Technical Specifications

Current measurement dc and ac 10 Hz to 100 Hz
Range : 40 A  Resolution: 10 mA
Accuracy, A: 1.5 % rdg + 15 digits
Trigger Level for Inrush: 0.50 A
Trigger Level for Hz Filter OFF: 2.50 A
Trigger Level for Hz Filter ON: 0.50 A
Range : 400 A  Resolution: 100 mA
Accuracy, A: 1.5 % rdg + 5 digits
Trigger Level for Inrush: 5.0 A
Trigger Level for Hz Filter OFF: 2.5 A
Trigger Level for Hz Filter ON: 2.5 A
Range : 2000 A; 1400 ac rms  Resolution: 1 A
Accuracy, A: 1.5 % rdg + 5 digits
Trigger Level for Inrush: 5 A
Trigger Level for Hz Filter OFF: 8 A
Trigger Level for Hz Filter ON: 8 A
Crest Factor (50/60 Hz)
Range : 40 A  Crest Factor* : 2 @ 33 A, 2.4 @ 27 A
Range : 400 A  Crest Factor* : 2 @ 330 A, 2.4 @ 270 A
Range : 2000 A; 1400 ac rms  Crest Factor* : 2 @ 1000 A, 2.4 @ 833 A
Current measurement ac 100.1 Hz to 1 kHz
Range : 40 A  Resolution: 10 mA
Accuracy > 10 A : 3.5 % rdg + 15 digits
Trigger Level for Inrush: 0.50 A
Trigger Level for Hz Filter OFF : 2.50 A
Trigger Level for Hz Filter ON : 0.50 A
Range : 400 A  Resolution: 100 mA
Accuracy > 10 A : 3.5 % rdg + 5 digits
Trigger Level for Inrush: 5.0 A
Trigger Level for Hz Filter OFF : 2.5 A
Trigger Level for Hz Filter ON : 2.5 A
Range : 2000 A; 1400 ac rms  Resolution: 1 A
Accuracy > 10 A : 3.5 % rdg + 5 digits
Trigger Level for Inrush: 5 A
Trigger Level for Hz Filter OFF : 8 A
Trigger Level for Hz Filter ON : 8 A
Voltage measurement (355 only) dc and ac 10 Hz to 100 Hz
(600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.)
Range : 4 V  Resolution: 1 mV
Accuracy: 1 % rdg + 10 digits
Trigger Level for Hz Filter OFF: 0.050 V
Trigger Level for Hz Filter ON: 0.050 V
Range : 40 V  Resolution: 10 mV
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 0.25 V
Trigger Level for Hz Filter ON: 0.25 V
Range : 400 V  Resolution: 100 mV
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
Range : 600 V ac rms  Resolution: 1 V
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
Range : 1000 V dc  Resolution: 1 V
Accuracy: 1 % rdg + 5 digits
Voltage measurement (355 only) ac 100.1 Hz to 1 kHz
(600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.)
Range: 4 V  Resolution: 1 mV
Accuracy: 3 % rdg + 10 digits
Trigger Level for Hz Filter OFF: 0.050 V
Trigger Level for Hz Filter ON: 0.050 V
Range: 40 V  Resolution: 10 mV
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 0.25 V
Trigger Level for Hz Filter ON: 0.25 V
Range: 400 V  Resolution: 100 mV
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
Range: 600 V ac rms  Resolution: 1 V
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
Ohms measurement (355 only)
Range: 400 Ω  Resolution: 0.1 Ω
Accuracy: 1.5 % + 5 digits
Range: 4 kΩ  Resolution: 1 Ω
Accuracy: 1.5 % + 5 digits
Range: 40 kΩ  Resolution: 10 Ω
Accuracy: 1.5 % + 5 digits
Range: 400 kΩ  Resolution: 100 Ω
Accuracy: 1.5 % + 5 digits
Continuity beeper (355 only)

 On at ≤ 30 Ω

 Off at ≥ 100 Ω
Frequency measurement
Measurement range  5.0 Hz to 1 kHz
Resolution  0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz)
Accuracy – 5.0 Hz to 100 Hz  0.2 % + 2 counts
Accuracy – 100.1 Hz to 1 kHz  0.5 % + 5 counts
Trigger level  Refer to current and voltage tables


*Add 2 % to error spec for CF > 2

General specifications
Batteries

 Six 1.5 V AA NEDA 15 A or IEC LR6
Battery life (with typical usage, backlight off)

 100 hours
Test leads

 Rated to 1000 V
Weight

 .814 kg (1.8 lb)
Jaw size

 58 mm (2.28 in)
Dimensions (LxWxD)

 300 mm x 98 mm x 52 mm (12 in x 3.75 in x 2 in)
Safety rating

 IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III
Environmental specifications
Operating temperature

 32 °F to + 122 °F (0 °C to +50 °C)
Storage temperature

 -4 °F to 140 °F (-20 °C to +60 °C)
Operating humidity

 0 to 95 % (non-condensing)
Operating altitude

 2000 m
Storage altitude

 10,000 m
IP rating

 42 (indoor use only)
Drop test requirements

 1 m
EMI, RFI, EMC

 FCC part 15, IEC/EN 61326-1:1997 class B, IEC/EN 61326:1997 3V/m, performance criteria B, EN61325
Temperature coefficients
Current:  0.1 % of reading per °C outside 22 °C to 24 °C
Voltage:  0.1 % of reading per °C outside 22 °C to 24 °C
Fluke 355 Clamp Meter - Datasheet Datasheets Fluke 355 Clamp Meter - User Manual Manuals & Guides

Reviews

Additional Information
SKU FLUCM8
Manufacturer Part Code 2840265
Model Ref Fluke 355
Country of Origin China