Fluke 2062 Advanced Pro Wire Tracer Kit

Perfect for testing scenarios in which critical equipment cannot be switched off, such as in hospitals, industrial plants, and factories, the Fluke 2062 Advanced Pro Wire Tracer Kit consists of a signal transmitter and Smart Sensor™ receiver. This wire-tracing set can be used to troubleshoot energised and de-energised wires in residential, commercial, and industrial environments to find, for instance, breaks, opens, and shorts. It is also suitable for identifying breakers and fuses. To this end, the Fluke 2062 Advanced Pro Wire Tracer Kit is safety-rated up to CAT IV 600V and provides protection against overvoltage spikes up to 8000 V.

Fluke 2062R Smart Sensor™ Receiver

Equipped with a patented Smart Sensor™, the Fluke 2062R Smart Sensor™ Receiver makes wire tracing faster and easier. The Smart Senor™ locates energised wires within walls, floors, and ceilings, and displays their positions and orientations on the high-resolution 3.5-inch TFT LCD colour display. Additionally, the tip sensor will issue an audible tone and proves particularly useful when tracing wires in corners, tight spaces, and junction boxes.

Capable of both passive (without the Fluke 200T Transmitter) and active (with the transmitter) tracing, the Fluke 2062R Smart Sensor™ Receiver is a versatile instrument. It can be optimised for various applications using the four operating modes:

  • Smart Sensor: for energised wire detection and visualisation
  • Tip Sensor: for precise wire detection
  • Breaker: uses the highest detected signal to identify breakers and fuses
  • Non-Contact Voltage Detection: trace energised wires without using the Fluke 200T Transmitter

The Fluke 2062R Smart Sensor™ Receiver also offers eight sensitivity levels which further improves its flexibility and accuracy.

Fluke 2000T Transmitter

Offering a 6kHz or 33kHz output frequency, the Fluke 2000T Transmitter automatically senses whether the circuit is energised or not and selects the appropriate output. Moreover, the Fluke 2000T Transmitter features three modes that change the strength of the signal to provide accurate results:

  • High: for normal energised and de-energised circuits
  • Low: for precision tracing; this mode reduces coupling to nearby wires and metal objects
  • Loop: for closed loop de-energised circuits

The Fluke 2062 Advanced Pro Wire Tracer Kit is a highly versatile, highly precise, highly efficient cable location and troubleshooting set.

Fluke 2062 Advanced Pro Wire Tracer Kit Key Features

  • Includes a Fluke 2062R Smart Sensor™ Receiver and Fluke 2000T Transmitter
  • Perfect for testing scenarios in which critical equipment can’t be switched off
  • Troubleshoot energised and de-energised wires in residential, commercial, and industrial environments
  • Find breaks, opens, and shorts
  • Identify breakers and fuses
  • Safety rated up to CAT IV 600V
  • Protected against overvoltage spikes up to 8000 V
  • Fluke 2062R Receiver is equipped with a patented Smart Sensor™
  • Smart Sensor™ locates energised wires and displays their positions and orientations
  • Fluke 2062R Receiver features a 3.5” TFT LCD colour display
  • The Fluke 2062R Receiver’s tip sensor issues an audible alert
  • Trace wires in corners, tight spaces, and junction boxes using the tip sensor
  • The Fluke 2062R Receiver supports both passive and active tracing
  • The Fluke 2062R Receiver has four operating modes: Smart Sensor, Tip Sensor, Breaker, and Non-contact Voltage
  • The Fluke 2062R Receiver has eight sensitivity levels
  • The Fluke 2000T Transmitter automatically detects whether the circuit is energised or de-energised
  • 6kHz and 33kHz transmitter output frequency
  • Three transmitter modes: High, Low, and Loop
  • Highly versatile, highly precise, highly efficient cable location and troubleshooting set

What’s Included?

  • Fluke 2062R Smart Sensor™ Receiver
  • Fluke 2000T Transmitter
  • Fluke i400 AC Current Clamp
  • Fluke 2000ACC Test Lead Accessory Kit
  • Smart Strap Magnetic Hanger
  • Batteries
  • Premium Hard Carrying Case
  • Quick Reference Guide

Fluke 2062 Advanced Pro Wire Tracer Kit Technical Specifications

  2062R Receiver 2000T Transmitter i400 AC Current Clamp
Measurement category CAT IV 600 V CAT IV 600 V CAT IV 600 V, CAT III 1000 V
Operating voltage 600 V AC/DC 600 V AC/DC 1000 V AC
Operating frequency Energized: 6.25 kHz Energized/Loop: 6.25 kHz N/A
De-Energized: 32.768 kHz De-Energized: 32.768 kHz
Signal indications Numeric, bar graph display and audible beep LEDs and audible beep N/A
Response time Smart Sensor: 500 ms
Tip Sensor (Energized/De-Energized): 500 ms
NCV: 500 ms
Battery monitoring: 5 s
Line voltage monitoring: 1 s
Battery voltage monitoring: 5 s
N/A
Current output
of signal (typical)
N/A Energized circuit:
High mode: 60 mA rms
Low mode: 30 mA rms
N/A
De-energized circuit:
High mode: 110 mA rms
Low mode: 40 mA rms
Loop mode with test leads: 160 mA rms
Loop mode with i400 AC Current Clamp:
385 mA rms
Signal voltage output
(nominal)
N/A Energized circuit:
High mode: 14 W @ 230 V ac/50 Hz,
3.33 kΩ @ 230 V ac
Low mode: 4.6 W @ 230 V ac/50 Hz,
11.5 kΩ @ 230 V ac
N/A
De-energized circuit:
High mode:
31 V RMS, 140 Vp-p, 0.86 W @ 1 kΩ load
Low mode:
27.5 V RMS, 120 Vp-p, 0.1 W @ 1 kΩ load
Loop mode with test leads:
32 V RMS, 140 Vp-p, 0.87 W @ 1 kΩ load
Loop mode with i400 AC Current Clamp:
31 mV, 0.89 W @ 1 Ω load
Range detection
(open air)
Smart Sensor Direction Indication Mode
≤15 cm (6 in), 230 V AC,
high mode, sensitivity level 2
N/A N/A
Tip Sensor: Energized
Max distance via air: up to 6.1 m (20 ft)
Pinpointing: approx. 5 cm (1.97 in)
Tip Sensor: De-Energized
Max distance via air: up to 4.5 m (14.7 ft)
Pinpointing: approx. 5 cm (1.97 in)
NCV (40 Hz to 400 Hz)
Max. sensitivity: 90 V up to 2 m
Min. sensitivity: 600 V up to 1 cm
Current range N/A N/A 400 A
Basic accuracy N/A N/A 2 % + 0.06 A
(45 Hz to 400 Hz)
Display
Display size LCD 89 mm (3.5 in) LEDs N/A
Display dimensions
(W x H)
70 mm x 52 mm (2.76 in x 2.07 in) N/A N/A
Display Resolution 480 px x 320 px N/A N/A
Display type Colour TFT LCD LEDs N/A
Display colour 16-bit Operating mode LEDs: red
Battery status LEDs: green, yellow, red
N/A
Backlight Yes N/A N/A
Environmental
Operating temperature -20 °C to 50 °C
(-4 °F to 122 °F)
-20 °C to 50 °C
(-4 °F to 122 °F)
-20 °C to 50 °C
(-4 °F to 122 °F)
Operating humidity 45%: -20 °C to <10 °C or 40 °C to 50 °C
(-4 °F to <50 °F or 104 °F to 122 °F)
95% (non-condensing): 10 °C to <30 °C
(50 °F to 86 °F)
75%: 30 °C to <40 °C (86 °F to <104 °F)
45%: -20 °C to <10 °C or 40 °C to 50 °C
(-4 °F to <50 °F or 104 °F to 122 °F)
95% (non-condensing): 10 °C to <30 °C
(50 °F to 86 °F)
75%: 30 °C to <40 °C (86 °F to <104 °F)
10 °C to <30 °C
(95%: 50 °F to <86 °F)
30 °C to <40 °C
(75%: 86 °F to <104 °F)
40 °C to <50 °C
(45%: 104 °F to <122 °F)
Operating altitude 2000 m (6561 ft) 2000 m (6561 ft) 2000 m (6561 ft)
Transient protection N/A 8.00 kV (1.2/50μS surge) N/A
Pollution degree 2 2 2
IP rating IP 40 IP 40 IP 40
Drop test 1 m (3.28 ft) 1 m (3.28 ft) 1 m (3.28 ft)
Mechanical
Power supply 4 x AA (alkaline) 8 x AA (alkaline)  
Power consumption
(typical)
110 mA High/low mode: 70 mA
Loop mode with Clamp: 90 mA
Consumption without signal
transmission: 10 mA
 
Battery life Approx. 20 h High/low mode: approx. 25 h
Loop mode: approx. 18 h
 
Low battery indication Yes Yes  
Fuse   1.6 A, 700 V, fast-acting,
Ø 6 x 32 mm, 50 kA interrupt
 
Maximum
conductor size
    32 mm (1.26 in)
Dimensions (L x W x H) Approx. 277 x 112 x 65 mm
(10.92 x 4.43 x 2.55 in)
Approx. 183 x 93 x 50 mm
(7.2 x 3.66 x 1.97 in)
Approx. 150 x 70 x 30 mm
(5.9 x 2.75 x 1.18 in)
Weight Approx. 0.544 kg (1.20 lb) Approx. 0.57 kg (1.25 lb) Approx. 0.114 kg (0.25 lb)

Fluke 2000ACC Test Lead Accessory Kit Technical Specifications

Includes 2x 1 m Test leads (red, black), 1x 7 m Test lead (green)
2x Test probes (black), 2x Alligator clips (red, black)
2x Outlet blade adapters (red, black), 2x Outlet round adapters (red, black)
Measurement category CAT IV 600 V (test leads), CAT II 1000 V (test probes), CAT IV 600 V (alligator clips),
CAT II 300 V (outlet adapters)
Operating voltage and
current
600 V, 10 A max. (red/black leads), 600 V, 10 A max. (green lead), 1000 V, 8 A max. (black probe)
600 V, 10 A max. (alligator clips), 300 V, 10 A max. (outlet adapters)
Operating temperature 0 °C to 50 °C (32 °F to 122 °F)
Operating humidity 10 °C to <30 °C (95 %: 50 °F to <86 °F), 30 °C to <40 °C (75 %: 86 °F to <104 °F),
40 °C to <50 °C (45 %: 104 °F to <122 °F)
Storage temperature
and humidity
0 °C to 60 °C (32 °F to 140 °F), <95 % (non-condensing)
Operating altitude 2000 m (6561 ft)
Pollution degree 2
Water and dust
resistance
IP 20
Drop proof 1 m (3.28 ft)
Dimensions Red/black leads: 1 m (3.28 ft), Green lead: 7 m (22.97 ft), Alligator clips: approx. 95 x 45 x 24 mm (3.74 x 1.77 x 0.94 in),
Outlet adapters: 72 x 18 x 18 mm (2.83 x 0.71 x 0.71 in)
Weight Approx. 0.4 kg (0.88 lb)