Perfect for testing scenarios in which critical equipment cannot be switched off, such as in hospitals, industrial plants, and factories, the Fluke 2062 Advanced Pro Wire Tracer Kit consists of a signal transmitter and Smart Sensor™ receiver. This wire-tracing set can be used to troubleshoot energised and de-energised wires in residential, commercial, and industrial environments to find, for instance, breaks, opens, and shorts. It is also suitable for identifying breakers and fuses. To this end, the Fluke 2062 Advanced Pro Wire Tracer Kit is safety-rated up to CAT IV 600V and provides protection against overvoltage spikes up to 8000 V.
Equipped with a patented Smart Sensor™, the Fluke 2062R Smart Sensor™ Receiver makes wire tracing faster and easier. The Smart Senor™ locates energised wires within walls, floors, and ceilings, and displays their positions and orientations on the high-resolution 3.5-inch TFT LCD colour display. Additionally, the tip sensor will issue an audible tone and proves particularly useful when tracing wires in corners, tight spaces, and junction boxes.
Capable of both passive (without the Fluke 200T Transmitter) and active (with the transmitter) tracing, the Fluke 2062R Smart Sensor™ Receiver is a versatile instrument. It can be optimised for various applications using the four operating modes:
The Fluke 2062R Smart Sensor™ Receiver also offers eight sensitivity levels which further improves its flexibility and accuracy.
Offering a 6kHz or 33kHz output frequency, the Fluke 2000T Transmitter automatically senses whether the circuit is energised or not and selects the appropriate output. Moreover, the Fluke 2000T Transmitter features three modes that change the strength of the signal to provide accurate results:
The Fluke 2062 Advanced Pro Wire Tracer Kit is a highly versatile, highly precise, highly efficient cable location and troubleshooting set.
2062R Receiver | 2000T Transmitter | i400 AC Current Clamp | |
Measurement category | CAT IV 600 V | CAT IV 600 V | CAT IV 600 V, CAT III 1000 V |
Operating voltage | 600 V AC/DC | 600 V AC/DC | 1000 V AC |
Operating frequency | Energized: 6.25 kHz | Energized/Loop: 6.25 kHz | N/A |
De-Energized: 32.768 kHz | De-Energized: 32.768 kHz | ||
Signal indications | Numeric, bar graph display and audible beep | LEDs and audible beep | N/A |
Response time | Smart Sensor: 500 ms Tip Sensor (Energized/De-Energized): 500 ms NCV: 500 ms Battery monitoring: 5 s |
Line voltage monitoring: 1 s Battery voltage monitoring: 5 s |
N/A |
Current output of signal (typical) |
N/A | Energized circuit: High mode: 60 mA rms Low mode: 30 mA rms |
N/A |
De-energized circuit: High mode: 110 mA rms Low mode: 40 mA rms Loop mode with test leads: 160 mA rms Loop mode with i400 AC Current Clamp: 385 mA rms |
|||
Signal voltage output (nominal) |
N/A | Energized circuit: High mode: 14 W @ 230 V ac/50 Hz, 3.33 kΩ @ 230 V ac Low mode: 4.6 W @ 230 V ac/50 Hz, 11.5 kΩ @ 230 V ac |
N/A |
De-energized circuit: High mode: 31 V RMS, 140 Vp-p, 0.86 W @ 1 kΩ load Low mode: 27.5 V RMS, 120 Vp-p, 0.1 W @ 1 kΩ load Loop mode with test leads: 32 V RMS, 140 Vp-p, 0.87 W @ 1 kΩ load Loop mode with i400 AC Current Clamp: 31 mV, 0.89 W @ 1 Ω load |
|||
Range detection (open air) |
Smart Sensor Direction Indication Mode ≤15 cm (6 in), 230 V AC, high mode, sensitivity level 2 |
N/A | N/A |
Tip Sensor: Energized Max distance via air: up to 6.1 m (20 ft) Pinpointing: approx. 5 cm (1.97 in) |
|||
Tip Sensor: De-Energized Max distance via air: up to 4.5 m (14.7 ft) Pinpointing: approx. 5 cm (1.97 in) |
|||
NCV (40 Hz to 400 Hz) Max. sensitivity: 90 V up to 2 m Min. sensitivity: 600 V up to 1 cm |
|||
Current range | N/A | N/A | 400 A |
Basic accuracy | N/A | N/A | 2 % + 0.06 A (45 Hz to 400 Hz) |
Display | |||
Display size | LCD 89 mm (3.5 in) | LEDs | N/A |
Display dimensions (W x H) |
70 mm x 52 mm (2.76 in x 2.07 in) | N/A | N/A |
Display Resolution | 480 px x 320 px | N/A | N/A |
Display type | Colour TFT LCD | LEDs | N/A |
Display colour | 16-bit | Operating mode LEDs: red Battery status LEDs: green, yellow, red |
N/A |
Backlight | Yes | N/A | N/A |
Environmental | |||
Operating temperature | -20 °C to 50 °C (-4 °F to 122 °F) |
-20 °C to 50 °C (-4 °F to 122 °F) |
-20 °C to 50 °C (-4 °F to 122 °F) |
Operating humidity | 45%: -20 °C to <10 °C or 40 °C to 50 °C (-4 °F to <50 °F or 104 °F to 122 °F) 95% (non-condensing): 10 °C to <30 °C (50 °F to 86 °F) 75%: 30 °C to <40 °C (86 °F to <104 °F) |
45%: -20 °C to <10 °C or 40 °C to 50 °C (-4 °F to <50 °F or 104 °F to 122 °F) 95% (non-condensing): 10 °C to <30 °C (50 °F to 86 °F) 75%: 30 °C to <40 °C (86 °F to <104 °F) |
10 °C to <30 °C (95%: 50 °F to <86 °F) 30 °C to <40 °C (75%: 86 °F to <104 °F) 40 °C to <50 °C (45%: 104 °F to <122 °F) |
Operating altitude | 2000 m (6561 ft) | 2000 m (6561 ft) | 2000 m (6561 ft) |
Transient protection | N/A | 8.00 kV (1.2/50μS surge) | N/A |
Pollution degree | 2 | 2 | 2 |
IP rating | IP 40 | IP 40 | IP 40 |
Drop test | 1 m (3.28 ft) | 1 m (3.28 ft) | 1 m (3.28 ft) |
Mechanical | |||
Power supply | 4 x AA (alkaline) | 8 x AA (alkaline) | |
Power consumption (typical) |
110 mA | High/low mode: 70 mA Loop mode with Clamp: 90 mA Consumption without signal transmission: 10 mA |
|
Battery life | Approx. 20 h | High/low mode: approx. 25 h Loop mode: approx. 18 h |
|
Low battery indication | Yes | Yes | |
Fuse | 1.6 A, 700 V, fast-acting, Ø 6 x 32 mm, 50 kA interrupt |
||
Maximum conductor size |
32 mm (1.26 in) | ||
Dimensions (L x W x H) | Approx. 277 x 112 x 65 mm (10.92 x 4.43 x 2.55 in) |
Approx. 183 x 93 x 50 mm (7.2 x 3.66 x 1.97 in) |
Approx. 150 x 70 x 30 mm (5.9 x 2.75 x 1.18 in) |
Weight | Approx. 0.544 kg (1.20 lb) | Approx. 0.57 kg (1.25 lb) | Approx. 0.114 kg (0.25 lb) |
Includes | 2x 1 m Test leads (red, black), 1x 7 m Test lead (green) 2x Test probes (black), 2x Alligator clips (red, black) 2x Outlet blade adapters (red, black), 2x Outlet round adapters (red, black) |
Measurement category | CAT IV 600 V (test leads), CAT II 1000 V (test probes), CAT IV 600 V (alligator clips), CAT II 300 V (outlet adapters) |
Operating voltage and current |
600 V, 10 A max. (red/black leads), 600 V, 10 A max. (green lead), 1000 V, 8 A max. (black probe) 600 V, 10 A max. (alligator clips), 300 V, 10 A max. (outlet adapters) |
Operating temperature | 0 °C to 50 °C (32 °F to 122 °F) |
Operating humidity | 10 °C to <30 °C (95 %: 50 °F to <86 °F), 30 °C to <40 °C (75 %: 86 °F to <104 °F), 40 °C to <50 °C (45 %: 104 °F to <122 °F) |
Storage temperature and humidity |
0 °C to 60 °C (32 °F to 140 °F), <95 % (non-condensing) |
Operating altitude | 2000 m (6561 ft) |
Pollution degree | 2 |
Water and dust resistance |
IP 20 |
Drop proof | 1 m (3.28 ft) |
Dimensions | Red/black leads: 1 m (3.28 ft), Green lead: 7 m (22.97 ft), Alligator clips: approx. 95 x 45 x 24 mm (3.74 x 1.77 x 0.94 in), Outlet adapters: 72 x 18 x 18 mm (2.83 x 0.71 x 0.71 in) |