A dual-channel, high-performance, portable, and rugged oscilloscope with a bandwidth of 100MHz, the Fluke 190-102-III ScopeMeter is ideal for troubleshooting, installing, commissioning, and maintaining industrial machinery, automation and process controls, and power conversion electronics (from DC to 500MHz). It features two independent, floating, isolated inputs (up to 1000V), a 5000-count digital multimeter, and has a CAT III 1000V/ CAT IV 600V safety rating, making it ideal for maintenance managers and consultants working in manufacturing, equipment installation, and field service.
Additionally, the Fluke 190-102-III ScopeMeter provides a fast sampling rate of up to 5.0 GS/s, a 200 ps resolution, and a deep memory with the capacity to store up to 10 000 samples per channel (in Scope mode). You can compare multiple test points across a circuit as well as take timing- and amplitude-related measurements. Furthermore, the Fluke 190-102-III ScopeMeter includes FFT analysis for the frequency spectrum.
The Fluke 190-102-III ScopeMeter captures accurate and detailed waveforms allowing you to see noise and other disturbances. This portable oscilloscope also includes a range of measurement/ memory functions to aid with diagnosing complicated problems such as complex waveforms, induced noise, intermittent events, and signal fluctuations or drift:
- TrendPlot™ Paperless Recorder: enables long-term automatic measurements; this mode plots key values allowing you to identify intermittent faults quickly.
- ScopeRecord mode: this mode stores up to 48 hours of data, ensuring you capture fast and intermittent glitches; it saves up to 30 000 points per input channel facilitating low-frequency signal analysis.
- Replay function: automatic capture and replay of up to 100 screens.
- Connect-and-View Triggering: intelligent, automatic triggering on fast, slow, and complex signals.
View data on the Fluke 190-102-III ScopeMeter’s large, bright, colour display. Saved data can be uploaded to a PC via a USB or Wi-Fi interface (FLUKE-190-102-III-S only as a Wi-Fi dongle is required). Other practical features include an IP51-rated, dust- and drip-proof casing with an easy-to-access battery door for quick, simple, on-site battery swaps.
The Fluke 190-102-III ScopeMeter Portable Oscilloscope is a dual-channel, durable, and dependable handheld oscilloscope and multimeter.
Fluke 190-102-III ScopeMeter Portable Oscilloscope Key Features
- Dual-channel, high-performance, portable, and rugged oscilloscope
- Bandwidth: 100MHz
- Ideal for troubleshooting, installing, commissioning, and maintaining industrial machinery, automation and process controls, and power conversion electronics (from DC to 500MHz)
- 5000-count digital multimeter
- CAT III 1000V/ CAT IV 600V safety rating
- Ideal for maintenance managers and consultants working in manufacturing, equipment installation, and field service
- Fast sampling rate: up to 5.0 GS/s
- Resolution: 200 ps
- Deep memory: store up to 10 000 samples per channel (in Scope mode)
- Compare multiple test points across a circuit
- Take timing- and amplitude-related measurements
- FFT analysis for frequency spectrum
- Captures accurate, detailed waveforms
- See noise and other disturbances
- Diagnose difficult problems like complex waveforms, induced noise, intermittent events, and signal fluctuations/ drift
- TrendPlot Paperless Recorder
- ScopeRecord mode
- Replay function
- Connect-and-View Triggering
- Large, bright, colour display
- Upload data to a PC via USB or Wi-Fi (FLUKE-190-102-III-S only as a Wi-Fi dongle is required)
- IP51
- Easy-to-access battery
- A dual-channel, durable, and dependable handheld oscilloscope and multimeter
What’s Included?
- Fluke 190-102-III ScopeMeter Portable Oscilloscope – 2 Channels, 100MHz
- Battery Charger/ Mains Adapter
- BP290 (10.8V, 2500mAh) Li-Ion Battery
- 2x VPS421-x Ruggedised Industrial-Grade Probes with Shrouded 4mm Banana Tips
- Large Jaw Alligator Clips (1x Red, 1x Blue)
- 2x TL175 Test Leads with Test Pins (1x Red, 1x Blue)
- Hangstrap
- Handstrap
- Download Information for User Manual and FlukeView®-2 Demo Package
- USB Interface Cable
- OPTIONAL SCC293 Kit (CXT293 Protective Carry Case, Activation Code for the Full Version of Fluke’s FlukeView Software, and Wi-Fi Dongle)
Kit Comparison
FLUKE-190-102-III | FLUKE-190-102-III-S | |
Fluke 190-102-III ScopeMeter | ✔ | ✔ |
Battery Charger/ Mains Adapter | ✔ | ✔ |
BP290 Battery | ✔ | ✔ |
2x VPS421-x Probes with 4mm Banana Tips | ✔ | ✔ |
2x Large Jaw Alligator Clips (1x Red, 1x Blue) | ✔ | ✔ |
2x TL175 Test Leads with Test Pins (1x Red, 1x Blue) | ✔ | ✔ |
Hangstrap | ✔ | ✔ |
Handstrap | ✔ | ✔ |
Download Information for User Manual | ✔ | ✔ |
Download Information for FlukeView®-2 Demo Package | ✔ | ✔ |
USB Interface Cable | ✔ | ✔ |
CXT293 Protective Carry Case | ✖ | ✔ |
Activation Code for the Full Version of Fluke’s FlukeView Software | ✖ | ✔ |
Wi-Fi Dongle | ✖ | ✔ |
Fluke 190 Series III ScopeMeter Portable Oscilloscopes Technical Specifications
Oscilloscope Models | |||||||
190-062 | 190-102 | 190-202 | 190-502 | 190-104 | 190-204 | 190-504 | |
Vertical deflection | |||||||
Number of channels | 2 | 2 | 2 | 2 | 4 | 4 | 4 |
Bandwidth | 60 MHz | 100 MHz | 200 MHz | 500 MHz | 100 MHz | 200 MHz | 500 MHz |
Rise time | 5.8 ns | 3.5 ns | 1.7 ns | 0.7 ns | 3.5 ns | 1.7 ns | 0.7 ns |
Number of scope inputs | 2 input channels plus external trigger | 4 input channels | |||||
Channel architecture | All inputs fully insulated from each other and from ground. Inputs may be activated in any combination. | ||||||
Input coupling | AC or DC, with ground level indicator | ||||||
Input sensitivity | With 10:1 probe, 20 mV to 1000 V/div With 100:1 probe, 200 mV to 10 kV/div Direct (1:1), 2 mV to 100 V/div |
||||||
Bandwidth limiter | 20 MHz and 10 kHz | ||||||
Polarity | Normal, Inverted, Variable | ||||||
Input voltage | CAT III 1000 V/CAT IV 600 V rated, see General specifications for further details | ||||||
Vertical resolution | 8 bit | ||||||
Accuracy at 4 s to 10 μs/div | 5 mV/div to 100 V/div, ±(1.5 % + 6 counts) 2 mV/div, ±(1.5 % + 10 counts) |
||||||
Input impedance | 1 MΩ (± 1 %) // 15 pF (± 2.25 pF) | ||||||
Horizontal | |||||||
Maximum real- time sample rate (sampled simultaneously) | 625 MS/s (each channel) |
1.25 GS/s (each channel) | 2.5 GS/s (each channel) | 5 GS/s (single channel) or 2.5 GS/s (dual channel) |
1.25 GS/s (each channel) | 2.5 GS/s (2ch) 1.25 GS/s (4ch) |
5 GS/s (single ch) or 2.5 GS/s (2ch) or 1.25 GS/s (4ch) |
Record length | Up to 10,000 samples per channel | ||||||
Time base range | 10 ns/div to 4 s/div |
5 ns/div to 4 s/div |
2 ns/div to 4 s/div |
1 ns/div to 4 s/div |
5 ns/div to 4 s/div |
2 ns/div to 4 s/div |
1 ns/div to 4 s/div |
Time base in a 1-2-4-sequence Slower time/division settings using ScopeRecord™ Roll mode (see ‘Recorder mode’) |
|||||||
Maximum record length | 10,000 samples per channel in scope mode 30,000 points per channel in ScopeRecord™ Roll mode (see ‘Recorder mode’) |
||||||
Timing accuracy | ± (0.01 % of reading + 1 pixel) | ||||||
Glitch capture | 8 ns (10 µs/div to 2 min/div) | ||||||
Display and acquisition | |||||||
Display | 133 mm x 90 mm (5.3 in x 3.5 in) full-color high brightness LCD | ||||||
Display modes | Any combination of channels; average on/off; replay. | ||||||
Visible screen width | 12 divisions horizontally in scope mode | ||||||
Digital persistence modes | Off, short, medium, long, infinite and envelope mode | ||||||
Waveform mathematics | One (190-xx2) or two (190-x04) mathematical operations on 2 input channels (A and B, C and D): add, subtract, multiply; X-Y-mode; Frequency Spectrum using FFT | ||||||
Acquisition modes | Normal, Averaged, Auto, Single Shot, ScopeRecord™ roll, glitch capture, waveform compare with automatic “Pass/Fail testing”; Replay | ||||||
Trigger and delay | |||||||
Source | Input A, B or External (via meter input) | Input A, B, C or D | |||||
Modes | Automatic, Edge, Pulse Width, N-Cycle, External (190-xx2) | ||||||
Connect-and- View™ | Advanced automatic triggering that recognizes signal patterns, automatically sets up and continuously adjusts triggering, time base and amplitude. Automatically displays stable waveforms of complex and dynamic signals like motor drive and control signals. Can be switched off if preferred. | ||||||
Pulse width triggering (on channel A) | Pulse width qualified by time Allows for triggering <t, >t, =t, ≠ t, where t is selectable in minimum steps of 0.01 div or 50 ns |
||||||
Time delay | 1 full screen of pre-trigger view or up to 100 screens (=1,200 divisions) of post-trigger delay | ||||||
Dual slope triggering | Triggers on both rising and falling edges alike | ||||||
N-cycle triggering | Triggers on N-th occurrence of a trigger event; N to be set in the range 2 to 99 | ||||||
Automatic capture of 100 screens | |||||||
When in oscilloscope mode, the instrument ALWAYS memorizes the last 100 screens—no specific user setup required. When an anomaly is seen, the REPLAY button can be pressed to review the full sequence of screen events over and over. Instrument can be set up for triggering on glitches or intermittent anomalies and will operate in “baby-sit” mode capturing 100 specified events. | |||||||
Replay | Manual or continuous replay. Displays the captured 100 screens as a “live” animation, or under manual control. Each screen has date and time-stamp. | ||||||
Replay storage | Ten sets of 100 screens each can be saved internally for later recall and analysis. Direct storage of additional sets on external flash memory drive through USB host port. | ||||||
FFT—frequency spectrum analysis | |||||||
Shows frequency content of oscilloscope waveform using Fast Fourier Transform | |||||||
Window | Automatic, Hamming, Hanning or None | ||||||
Automatic window | Digitally re-samples acquired waveform to get optimum frequency resolution in FFT resultant. | ||||||
Vertical scale | Linear/Logarithmic (in volts or amps) | ||||||
Frequency axis | Frequency range automatically set as a function of timebase range of oscilloscope | ||||||
Waveform compare and pass/fail testing | |||||||
Waveform compare | Provides storage and display of a reference waveform for visual comparison with newly acquired waveforms. Reference is derived from an acquired waveform and can be modified in the oscilloscope. | ||||||
Pass/Fail testing | In waveform compare mode, the oscilloscope can be set up to store only matching (“Pass”) or only non-matching (“Fail”) acquired waveforms in the replay memory bank for further analysis. | ||||||
Automatic scope measurements | |||||||
V dc, V ac rms, V ac+dc, Vpeak max, Vpeak min, Vpeak to peak, A ac, A dc, A ac+dc, frequency (in Hz), rise time (using cursors), fall time (using cursors), Power Factor (PF), Watts, VA, VA reactive, phase (between 2 inputs A&B or C&D), pulse width (pos./neg.), duty cycle (pos./ neg.), temperature °C, temperature °F (not for Japan), dBV, dBm into 50 Ω and 600 Ω, VPWM ac and VPWM(ac+dc) for measurement on pulse width modulated motor drives and frequency inverters, V/Hz ratio; | |||||||
Advanced power and motor drive functions | V/Hz ratio, Power Factor (PF), Watts, VA, VA reactive, V-PWM (ac) and V-PWM (ac+dc) for measure- ment on pulsewidth modulated motordrives and frequency inverters | ||||||
Cursor measurements | |||||||
Source | On any input waveform or on mathematical resultant waveform (excl. X-Y-mode) | ||||||
Dual horizontal lines | Voltage at cursor 1 and at cursor 2, voltage between cursors | ||||||
Dual vertical lines | Time between cursors, 1/T between cursors (in Hz), voltage between markers, risetime with markers, falltime with markers; Vrms between cursors, Watts between cursors. | ||||||
Single vertical line | Min-Max and Average voltage at cursor position; frequency and rms-value of individual frequency component in the FFT Resultant | ||||||
Advanced functions | mA*s (current-over-time, between cursors); V*s (voltage-over-time, between cursors); W*s (energy, between cursors) | ||||||
ZOOM | Ranges from full record overview to zoom in up to sample level, at any record length. | ||||||
Meter modes | |||||||
190-062 | 190-102 | 190-202 | 190-502 | 190-104 | 190-204 | 190-504 | |
Meter inputs | Via 4 mm banana inputs, fully isolated from scope inputs and scope ground | Via BNC scope inputs | |||||
Number of readings | One at a time via DMM input | Up to 4 automatic scope measurements simultaneously | |||||
Maximum resolution | 5,000 counts | ± 999 counts (frequency: 9999 counts) |
|||||
Input impedance | 1 MΩ (± 1 %) // 14 pF (± 1.5 pF) | 1 MΩ (± 1 %) // 15 pF (± 2.25 pF) | |||||
Advanced meter functions | Auto/manual ranging, relative measurements (Zero reference), TrendPlot™ recording | ||||||
Note | The specified accuracy is valid over the temperature range 18 °C to 28 °C Add 10 % of specified accuracy for each degree C below 18 °C or above 28 °C | ||||||
Voltage | |||||||
V dc accuracy | ± (0.5 % + 6 counts) | ± (1.5 % + 6 counts) | |||||
V ac true rms accuracy | |||||||
15 Hz to 60 Hz | ± (1 % + 10 counts) | ± (1.5 % + 10 counts) | |||||
60 Hz to 1 kHz | ± (2.5 % + 15 counts) | - | |||||
60 Hz to 20 kHz | - | ± (2.5 % + 15 counts) | |||||
Voltmeter ranges | 500 mV, 5 V, 50 V, 500 V, 1,100 V | ||||||
Resistance | |||||||
Ranges | 500 Ω, 5 kΩ, 50 kΩ, 500 kΩ, 5 MΩ, 30 MΩ | - | |||||
Accuracy | ± (0.6 % + 6 counts) | - | |||||
Other meter functions | |||||||
Continuity | Beeper on < 50 Ω (± 30 Ω) | - | |||||
Diode test | Up to 2.8 V | - | |||||
Current (A) | A dc, A ac, A ac+dc using an optional current clamp or shunt Scaling factors: 0.1 mV/A, 1 mV/A to 100 V/A and 400 mV/A | ||||||
Temperature | With optional accessories. Scale factors 1mV/°C or 1mV/°F | ||||||
ScopeRecord™ Roll Mode | |||||||
Dual or multiple input waveform storage mode, using deep memory | |||||||
Source and display | Input A, Input B, Dual All channels sampled simultaneously |
Any combination of inputs, up to 4 channels. All channels sampled simultaneously |
|||||
Memory depth | 30,000 data points per channel, each holding min/max pair of information | ||||||
Min/max values | Min/max values are created at samples that are measured at high sample rate ensuring capture and display of glitches. | ||||||
Recording modes | Single sweep, continuous roll; Start-on-Trigger (through external); Stop-on-Trigger (through external) | Single sweep, continuous roll; Start-on-Trigger (through any channel); Stop-on-Trigger (through any channel) | |||||
Stop-on-trigger | ScopeRecord mode can be stopped by an individual trigger event, or by an interruption of a repetitive trigger signal, through any input channel (through External on 190-XX2 Series) |
||||||
Horizontal scale | Time from start, time of day | ||||||
Zoom | Ranges from full record overview to zoom in up to sample level | ||||||
Memory | Two multiple input ScopeRecord waveforms can be saved internally for later recall and analysis. | ||||||
ScopeRecord™ Roll mode sample rate and recording timespan | |||||||
Time base range | 4 ms/div to 2 min/div | ||||||
Recorded timespan | 4.8 sec to 40 hr | ||||||
Time/division in ‘view all’ mode | 0.4 s/div to 4 h/div | ||||||
Glitch capture | 8 ns | ||||||
Sample rate | 125 MS/s | ||||||
Resolution | 160 μsec ~ 4.8 sec | ||||||
Trendplot™ Recording | |||||||
Multiple channel electronic paperless recorder. Graphically plots, displays and stores results of up to four automatic scope measurements or a DMM-reading over time. | |||||||
Source and display | Any combination of scope measurements, made on any of the input channels, or DMM reading (2-channel instruments) | ||||||
Memory depth | 19,200 points (sets) per recording. Each recorded sample point contains a minimum, a maximum and an average value, plus a date- and time-stamp. | ||||||
Ranges | Normal view: 5 s/div to 30 min/div; In view-all mode: 5 min/div to 48 hr/div (overview of total record) | ||||||
Recorded time span | Up to 22 days, with a resolution of 102 seconds; up to 5.5 days for 4 readings. | ||||||
Recording mode | Continuous recording, starting at 5 s/div with automatic time-scale compression | ||||||
Measurement speed | Three automatic measurements per second or more | ||||||
Horizontal scale | Time from start, time of day | ||||||
Zoom | Up to 64x zoom-out for full record overview, up to 10x zoom-in for maximum detail | ||||||
Memory | Two multiple input TrendPlot records can be saved internally for later recall and analysis. | ||||||
Cursor measurements—all recorder modes | |||||||
Source | Any waveform trace in any waveform display mode (Scope, ScopeRecord or TrendPlot) | ||||||
Dual vertical lines | Cursors may be used to identify Min, Max or Average value of any datapoint in a record, with time between cursors, time from start or absolute time. | ||||||
General specifications | |||||||
Input voltage range | |||||||
Rated maximum floating voltage | CAT III 1000 V / CAT IV 600 V (maximum voltage between any contact and earth-ground voltage level) | ||||||
Probe input voltage VPS410-II | CAT III 1000 V / CAT IV 600 V (Maximum voltage between standard 10:1 probe tip and reference lead) | ||||||
Probe input voltage VPS421 | CAT III 1000V / CAT IV 600V (Maximum voltage between probe tip or reference lead to GND, 2000V max between probe tip and reference lead) | ||||||
Maximum BNC input voltage | CAT IV 300 V (maximum voltage on BNC input directly) | ||||||
Maximum volt- age on meter input | CAT III 1000 V / CAT IV 600 V (safety designed banana input connectors) |
- | |||||
Memory save and recall | |||||||
Memory loca- tions (internal) | 30 waveform memories plus 10 recording memories plus 9 screen copy memories | ||||||
30 waveform memories | Each memory can contain up to 2 or 4 waveforms plus corresponding setups. | ||||||
10 recording memories | Each may contain: a 100 Screen Replay sequence, or a ScopeRecord Roll-mode recording (2 or 4 traces), or a TrendPlot recording of up to 4 measurements | ||||||
External data storage | On PC, using FlukeView™-2 Software, or direct storage on external flash memory drive (maximum 32 GB) through USB host port | ||||||
Screencopies | On PC, using FlukeView™-2 Software, or internally (in instrument) which can be copied on to external flash memory drive as .BMP-file, through USB host port | ||||||
Volatility | Saving is done in non-volatile Flash-ROM and all data is secured, independent of battery or power status. | ||||||
Real-time clock | Provides date and time stamp information for ScopeRecord, for 100 Screen Replay sequences and for TrendPlot recordings. | ||||||
Case | |||||||
Design | Rugged, shock-proof with integrated protective holster. Handstrap and hangstrap included as standard. Kensington lock supported to lock down instrument when left unattended. |
||||||
Drip and dustproof | IP 51 according to IEC60529 | ||||||
Shock and vibration | Shock 30 g, vibration (sinusoidal) 3 g / 0.03 g2/Hz (Random), according to MIL-PRF-28800F Class 2 | ||||||
Display size | 133 mm x 90 mm (5.3 in x 3.5 in) LCD | ||||||
Resolution | 1120 pixels x 765 pixels | ||||||
Brightness | User-adjustable, up to 300 cd/m2 | ||||||
Mechanical data | |||||||
Size | 265 mm x 192 mm x 70 mm (10.5 in x 7.6 in x 2.8 in) | ||||||
Weight (including battery) | 2.1 kg (4.6 lb) | 2.2 kg (4.8 lb) | |||||
Power | |||||||
Line power | Universal mains adapter/battery charger BC190/830 included, with detachable 2-wire power cords 100 Vac to 240 Vac, ±10 %, 50-60 Hz | ||||||
Battery power | Re-chargeable Li-Ion battery (included). Battery swappable through easily accessible battery door at the rear of the instrument | ||||||
Battery type (incl.) and capacity [+opt. battery] | BP290: 10.8V, 2500 mAh [BP291 (5000 mAh) optional] |
BP291: 10.8V, 5000 mAh | |||||
Battery charge indicator | Battery has built-in status indicator for use with external charger, next to battery status indicator on instrument screen. | ||||||
Battery operat- ing time (with backlight low) | Up to 3.5 using BP290 (included), up to 7 hours using BP291 (optional) | Up to 7 hours using BP291 (included) | |||||
Battery charging time | 2½ hours using BP290; 5 hours using BP291 | Five hours for BP291 | |||||
Battery power saving functions | Auto ‘power down’ with adjustable power down time. Automatic ‘display off’ with adjustable power down time. On-screen battery power indicator |
||||||
Safety | |||||||
Compliance | EN61010-1, Pollution Degree 2; IEC 61010-2-030: CAT IV 600 V / CAT III 1000 V |
||||||
Environmental | |||||||
Operating temperature | Battery discharging: 0 °C to 40 °C (32 °F to 104 °F) Battery charging: 0 °C to 40 °C (32 °F to 104 °F) |
||||||
Storage temperature | -20 °C to 60 °C (-4 °F to 140 °F) | ||||||
Humidity | 0 °C to 10 °C (32 °F to 50 °F): noncondensing 10 °C to 30 °C (50 °F to 86 °F): 95 % (±5 %) 30 °C to 40 °C (86 °F to 104 °F): 75 % (±5 %) 40 °C to 50 °C (104 °F to 122 °F): 45 % (±5 %) |
||||||
Maximum operating altitude | CAT IV 600 V, CAT III 1000 V: up to 2000 m (6 600 feet) CAT IV 300 V, CAT III 600 V, CAT II 1000 V: up to 4000 m (13 000 feet) |
||||||
Maximum storage altitude | 12 km (40,000 ft) | ||||||
Electro-Magnetic Compatibility (EMC) | IEC 61326-1: Industrial; CISPR 11: Group 1, Class A; Korea (KCC): Class A Equipment (Industrial Broadcasting and Communication Equipment); USA (FCC): 47 CFR 15 subpart C. |
||||||
Interfaces | Two USB-ports provided. Ports are fully insulated from instrument’s floating measurement circuitry. USB-host port directly connects to external flash memory drive (up to 32 GB) for storage of waveform data, measurement results, instrument settings and screen copies. Alternatively, this USB-A port may be used to connect a WiFi Adapter for wireless PC connectivity. A mini-USB-B is provided which allows for interconnection to PC for remote control and data transfer under PC-control using FlukeView-2. |
||||||
Probe calibration output | Dedicated probe-cal output with reference contact provided, fully insulated from any measurement input channel. Generator Output: 1.225 Vpp / 500 Hz square wave |
||||||
Warranty | 3 years on main instrument, 1 year on battery and accessories |