Fluke 1775 Three-Phase Power Quality Analyser - Choice of Kit
A two-in-one power quality analyser and power quality meter, the Fluke 1775 Three-Phase Power Quality Analyser logs and analyses data and can be used to troubleshoot issues. It measures over five hundred parameters including harmonics, dips, swells, unbalances, voltage, current, and power. Additionally, the Fluke 1775 Three-Phase Power Quality Analyser offers high-speed transient capture up to ±8kV with a sample rate of 1MS/s. The middle model in Fluke’s 1770 Series of PQAs, the Fluke 1775 Three-Phase Power Quality Analyser is ideal for energy surveys, load testing, harmonic surveys, nuisance circuit breaker tripping, power utility power quality surveys, and discovering equipment failures caused by transients.
An eclectic and comprehensive automatic measurement capture ensures you collect the correct data for the system you are working on, whilst also allowing you to alter and adjust parameters as necessary. A streamlined user interface makes it easy to swap between measurement parameters, while the Fluke 1775’s PQ Logging and Analysis function provides guided setups for easy configuration and measurement selection. Guided setups also digitally autocorrect connection errors without users having to make any physical probe alterations. In addition to this, the Fluke 1775 Three-Phase Power Quality Analyser supports the creation of custom views allowing you to tailor the PQA to your application.
A PQ Meter function provides immediate access to live data, allowing you to identify potential problems quickly while troubleshooting. Data is visible on the Fluke 1775 Three-Phase Power Quality Analyser’s large, bright, touchscreen display. It can be transferred to a PC via a USB or Wi-Fi interface without interrupting power quality and energy studies.
Once data has been downloaded to a PC, you can use Fluke’s Energy Analyse Plus Software to view and share results. This software can also be used to create customised reports and includes a one-click function for generating industry standard EN50160/ IEEE 519/ GOST 33073 reports.
Finally, this ergonomic power quality analyser is powered directly via the measurement circuit: the Fluke 1775 Three-Phase Power Quality Analyser is not limited by the location of power outlets and the length of extension cords.
Featuring automatic measurement capture technology, a simplified reporting platform, and an easy-to-use interface, the Fluke 1775 Three-Phase Power Quality Analyser is optimised for simplicity and efficiency. It is ideal for troubleshooting electrical systems and power and energy logging.
Optional Fluke Premium Care - 1 Year (UK Only)
- Accidental damage and repair costs included
- Expedited calibration and repair
- Annual tool inspection, calibration, and updating
- Replacement of damaged accessories (Some limitations apply, see Fluke Terms and Conditions)
Select the Premium Care option in the dropdown box when choosing the model you wish to purchase, only available for users in the UK. Please visit our Blog for more information.
Videos
Pass Presents - Guide to the 1770 Series
Overview
Key Features
- A two-in-one power quality analyser and power quality meter
- Log and analyse data
- Troubleshoot electrical issues
- Measures over five hundred parameters
- Harmonics
- Dips
- Swells
- Unbalance
- Voltage
- Current
- Power
- High-speed transient capture up to ±8kV
- Transient capture sample rate: 1MS/s
- Ideal for energy surveys, load testing, harmonic surveys, nuisance circuit breaker tripping, power utility power quality surveys, and uncovering equipment failures caused by transients
- Automatic measurement capture
- Streamlined user-interface
- PQ Logging and Analysis function provides guided setups
- Guided setups for easy configuration and measurement selection
- Guided setups digitally autocorrect connection errors
- Custom views: tailor the PQA to carry out tests and collect the data relevant to your application
- PQ Meter function: provides immediate access to live data
- Large, bright, touchscreen display
- Transfer data to a PC without interrupting power quality and energy studies
- Download data via a USB or Wi-Fi interface
- Use Fluke’s Energy Analyse Plus Software to view and share results, and create customised and/or industry-standard reports
- Power the PQA via the measurement circuit
- Simplified reporting platform
- Optimised for simplicity and efficiency
- Ideal for troubleshooting electrical systems and power and energy logging
What’s Included?
- Fluke 1775 Three-Phase Power Quality Analyser
- OPTIONAL 4x i17XX-FLEX1500 1500A Current Clamp (2m)
- OPTIONAL 1-Year Premium Care (UK Only)
- 1x FLUKE-17XX Flat Cable Voltage Test Lead
- 4x AC285 Black Alligator Clip
- 1x AC285 Green Alligator Clip
- 1x USB-C Cable
- 1x Line Cord
- 1x FLK-17XX 0.18M Test Lead Set
- 1x Green Test Lead
- OPTIONAL 1x MPI-3R/1B Magnet Probe Set (3x Red, 1x Black)
- OPTIONAL 1x FLUKE-174X-HANGER Kit
- OPTIONAL 1x FLUKE-177X-4204 WIFI/BLE Module
- Cable Marker Set (For Voltage and Current)
- FLUKE-174X-MA-C8 Wall Outlet Adapter
- 1x Statement of Calibration Practices
- 1x Black Soft Case
Kit Comparison
FLUKE 1775 | FLUKE 1775/BASIC | |
---|---|---|
Fluke 1775 Three-Phase Power Quality Analyser | ✔ | ✔ |
Optional 1-Year Premium Care (UK Only) | ✔ | ✖ |
4x i17XX-FLEX1500 1500A Current Clamp (2m) | ✔ | ✖ |
1x FLUKE-17XX Flat Cable Voltage Test Lead | ✔ | ✔ |
4x AC285 Black Alligator Clip | ✔ | ✔ |
1x AC285 Green Alligator Clip | ✔ | ✔ |
1x USB-C Cable | ✔ | ✔ |
1x Line Cord | ✔ | ✔ |
1x FLK-17XX 0.18M Test Lead Set | ✔ | ✔ |
1x Green Test Lead | ✔ | ✔ |
1x MPI-3R/1B Magnet Probe Set (3x Red, 1x Black) | ✔ | ✖ |
1x FLUKE-174X-HANGER Kit | ✔ | ✖ |
1x FLUKE-177X-4204 WIFI/BLE Module | ✔ | ✖ |
1x Cable Marker Set (For Voltage and Current) | ✔ | ✔ |
1x FLUKE-174X-MA-C8 Wall Outlet Adapter | ✔ | ✔ |
1x Statement of Calibration Practices | ✔ | ✔ |
1x Black Soft Case | ✔ | ✔ |
- PASS Power Bank & Magnetic Wireless Charger (10 000mAh 15W) - PASSPOWER-PLUS, typically £49.00
Fluke 1770 Series Three-Phase Power Quality Analyser Comparison Chart
1773 | 1775 | 1777 | |
Max input voltage rms 1000Vac/1500Vdc |
✔ | ✔ | ✔ |
Voltage Channels / Amp Channels |
5/4 | 5/4 | 5/4 |
Flex 150/1500A 12” 4x | ✔ | ✔ | ✔ |
PQ Health (EN 50160) | ✔ | ✔ | ✔ |
DC voltage, DC current (with optional clamps) |
✔ | ✔ | ✔ |
Live Scope/Phasor Diagram | ✔ | ✔ | ✔ |
Live Reading Trending | ✔ | ✔ | ✔ |
Internal Storage Memory (External SD Slot) |
8GB (32GB available) |
8GB (32GB available) |
8GB (32GB available) |
Battery (swappable) | 1hrs | 1hrs | 1hrs |
Transients 20 MHz 8kV (Volt only) |
✖ | 1MHz sampling |
20MHz sampling |
Event List | ✔ | ✔ | ✔ |
RMS profile capture and Waveform data |
✖ | ✔ | ✔ |
Input 2x ac+dc 10V **** | ✔ | ✔ | ✔ |
IEC 61000-4-30 Class A Ed. 4 (Unreleased) | Engineered to meet future Class A Ed. 4 requirements |
||
Harmonics 2-9 kHz (Volt and Amp) | ✔ | ✔ | ✔ |
Harmonics to 30kHz | ✔ | ✔ | ✔ |
Interval 200ms rms 3s Harm. |
✔ | ✔ | ✔ |
Display 7” Touch | ✔ | ✔ | ✔ |
Ethernet/WiFi (2x)/BLE |
✔ (Wi-Fi optional) |
✔ | ✔ |
Automatically powers from measurement line |
✔ | ✔ | ✔ |
Connection verification and autocorrection |
✔ | ✔ | ✔ |
Fluke 1770 Series Three-Phase Power Quality Analyser Technical Specifications
Voltage inputs | ||
Number of inputs | 4 inputs, 3 phases and neutral referenced to PE (5 connectors) | |
Measurement category | 1000 V CAT III / 600 V CAT IV | |
Maximum input voltage | 1000 V rms / 1000 V dc (1700 Vpk) | |
Nominal voltage range | Wye and single phase: variable (50 V – 1000 V) Delta: Variable (100 V – 1000 V) IEC 61000-4-30 Class A compliance for the nominal voltages (Vdin) 100 V – 690 V |
|
Input impedance | 10 MΩ between P-P and P-N, 5 MΩ between P-PE and N-PE | |
Bandwidth | DC to 30 kHz for PQ measurements, excluding transients | |
Resolution | 24-bit synchronous sampling | |
Sampling frequency | 80 kS/s at 50/60 Hz | |
Scaling | 1:1, variable for use of potential transformers | |
Voltage transients | ||
Measurement range | ±8 kV | |
Sampling rate | 1775: 1 MS/s | |
1777: 1 MS/s, 20 MS/s | ||
Bandwidth | DC to 1 MHz | |
Trigger | Adjustable trigger level. Triggers on high-frequency components > 1.5 kHz | |
Resolution | 14-bit synchronous sampling | |
Current inputs | ||
Number of inputs | 4 inputs 3 phases and Neutral, range selected automatically to attached sensor | |
Range | AC | 1 A to 1500 A with i17XX-FLEX1500 12 |
1 A to 1500 A with i17XX-FLEX1500 24 | ||
3 A to 3000 A with i17XX-FLEX3000 24 | ||
6 A to 6000 A with i17XX-FLEX6000 36 | ||
40 mA to 40 A with clamp i40s-EL | ||
4 A to 400 A with clamp i400s-EL | ||
DC | 20 A to 2000 A with 80i-2010-EL clamp | |
Bandwidth | DC to 30 kHz | |
Resolution | 24-bit synchronous sampling | |
Sampling frequency | 80 kS/s at 50/60 Hz | |
Scaling | 1:1, variable | |
Input voltage | Clamp: 50 mV / 500 mV rms; CF 2.8 | |
Rogowski Coil: 15 mV / 150 mV rms at 50 Hz, 18 mV / 180 mV rms at 60 Hz; CF 4 all at nominal probe range |
||
Input impedance | 11 kΩ |
Reviews
SKU | FLUKE-1775-X |
---|