Free Beanie Hat. Spend £250+ (ex VAT) View
All Fluke Products

Fluke 1748/ EUS Three-Phase Power Quality Logger – Choice of Kit

SKU
Fluke/1748/EUS
Rating:
0%
(0)
Reward Points
:
8268
£8,268.00 £6,890.00
Free UK Delivery*
Choose a Special Offer
  • PASS Power Bank & Magnetic Wireless Charger
    PASS Power Bank & Magnetic Wireless Charger (10 000mAh 15W)
    FREE
    £49.00
  • PASS Power Bank & Magnetic Wireless Charger (10 000mAh 15W) SKU: (PASSPOWER-PLUS)
    FREE
    £49.00
    PASS Power Bank & Magnetic Wireless Charger
    • Supports magnetic wireless charging
    • Supports wired charging
    • 10 000mAh 15W
Advice & Support Call 01642 931329 or contact us
Price Match We won't be beaten, let us know
FREE Powerbank / Wireless Charger
Fluke 1748/ EUS Power Quality Logger - With Magnetic Hanger

Fluke 1748/ EUS Three-Phase Power Quality Logger - Choice of Kit

The Fluke 1748/ EUS Power Quality Logger can be used to perform quality of service surveys, quantify energy usage and troubleshoot power distribution systems, allowing the technician/ engineer to make critical power quality and energy decisions in real-time.

This power quality logger is optimised for European, UK and US markets and is available in three kits that vary in regards to the included flexible current probes: 

  • FLUKE 1748/B/EUS - WITHOUT Probes
  • FLUKE 1748/15/EUS - with 1500A iFlex Probes
  • FLUKE 1748/30/EUS - with 3000A iFlex Probes  

Measurement Features

The Fluke 1748/ EUS Three-Phase Power Quality Logger is compliant with IEC 61000-4-30 Class A Edition 3 standards and can be used to log up to five-hundred parameters simultaneously. The highly accurate Fluke  Power Quality Logger can monitor and log the following parameters (amongst others):

  • Harmonics for voltage and current
  • Interharmonics for voltage and current
  • Unbalance
  • Flicker
  • Rapid voltage changes

This instrument can also be used to measure neutral current and all three current and voltage phases (when used with three-phase and neutral voltage test leads, and flexible current probes). In addition to monitoring up to five-hundred power parameters, the Fluke 1748/ EUS can capture events. It can be used to record event waveforms as well as determine an RMS event profile which includes the date, time and any severity information. These additional features mean it can be used to identify root causes of power quality issues.

The comprehensive measurement and event capture capabilities make is suited to assessing power quality in accordance with EN 50160 and IEEE 519 standards, whether testing at the service entrance, substation or at the load.

Memory and Data Download

The Fluke 1748/ EUS ensures that measurement trends are complete by automatically logging a variety of power quality and power variables. It is possible to save in excess of twenty separate logging sessions to the logger.

Recorded measurements may be downloaded to a USB drive and/or communicated to PC via a wired or Wi-Fi connection. It is also possible to transfer data via an Ethernet connection. It includes two USB ports allowing the user to connect the instrument to a PC and a USB drive, enabling him/her to log data continuously and without having to remove the Power Quality Logger from the field. Wi-Fi connectivity also allows the user to view data remotely outside of dangerous environments, reducing the need for expensive PPE.  

Analysis and Reporting

The Fluke 1748/ EUS Three-Phase Power Quality Logger is supplied with Fluke’s Energy Analyse Plus Software. This program can be used to view data remotely and in real-time using a Wi-Fi connection, analyse logged data, and create standardised reports. At the touch of a button, the Energy Analyse Plus Software is able to create EN 50160, IEEE 519, GOST 33073 reports. The user may adjust the report templates to remain in-line with standards as they evolve.

This software program can also be used to export data in PQDIF or NeQual formats allowing it to be used with third-party software.

Furthermore, the Energy Analyse Plus Software can be used to analyse every detail of energy consumption and power-quality state-of-health. The user is able to select a particular parameter to create a customised view of logged measurements and facilitates advanced data correlation. It is possible to view hour/hour, day/day and week/week comparisons by selecting the relevant thumbnail.

Moreover, this software program will calculate the limits of current harmonics based on the installation parameters thereby enabling the user to predict grid overload according to a range of international standards. This, in turn, allows the technician or engineer to prevent unexpected failures or non-compliance situations by monitoring harmonics before distortion appears in the voltage, thereby increasing the system’s uptime.

Ergonomic, Rugged Design

System Interface

Equipped with a quick, guided and graphical PC-based application setup ensuring that the user is always able to capture the desired data. Further to this, the intelligent verification feature ensures that the necessary test leads and clamps are connected correctly. If a connection error is detected the power button will display an amber light, this changes to green when the connection is corrected. The Fluke 1748/ EUS is capable of correcting connections digitally without the user having to remove connected leads or clamps. 

Also improving this instrument’s ease-of-operation is its automatic detection, scaling and powering of the connected probes, thereby ensuring the accuracy of detected measurements. Moreover, up to four current probes can be connected separately to the Three-Phase Power Quality Logger thereby allowing for greater flexibility.

Physical Design

Fluke 1748/ EUS Three-Phase Power Quality Logger in Use

Similarly improving the Fluke Power Quality Logger’s flexibility is its ability to be powered by the circuit it is testing; this instrument has a wide power range and will automatically go from 100V to 500V. Alternatively; it may be powered by a wall line cord. Its wide power range and ability to be powered using various methods expand the Power Quality Logger’s scope-for-use.

It is equipped with a lithium-ion battery with an operating time of four hours per charge ensuring that it is able to withstand temporary power disruptions.

Additionally, the Fluke 1748/ EUS Three-Phase Power Quality Logger has the highest safety rating in the industry, again expanding its scope-for-use. With a rating of 600V CAT IV/ 1000V CAT III, it can be used at service entrances and downstream.

Its small size also adds to the versatility as it can be placed in tight spaces; it has the following dimensions 23cm x 18cm x 5.4cm. The supplied magnetic hanger ensures that the Three-Phase Power Quality Logger can be stored safely inside or outside the panel.

When left on-site, the logger may be safeguarded against theft using a standard chain or another security instrument, whilst its rugged, IP65 design (when used with an IP65 voltage input adapter) ensures that it is protected against physical damage when used or left on-site. All of the Fluke 1748/ EUS Three-Phase Power Quality Logger’s ports (AUX, I/O, USB and Ethernet) are compliant with IP65 ensuring that they are resistant to dust and moisture ingress when not in use.

Accessories

The supplied flexible current probes (NOT supplied with the Fluke 1748/ B/EUS version) are also IP65 certified, making them suitable for most installations. They are thin in design ensuring that they can be used to access tight spaces and include a wide range (probe dependent) for high accuracy in each application. Moreover, the included 2m leads allow the user to access awkwardly located conductors.

The Fluke 1748/ EUS Three-Phase Power Quality Logger is a practical, portable and precise three-phase power quality logger.

Key Features

  • Perform quality of service surveys, quantify energy usage and troubleshoot power distribution systems
  • Allows the engineer/ technician to make critical power quality and energy decisions in real-time
  • Optimised for European, UK and US markets
  • Available in three kits with different current probes
  • Compliant with IEC 61000-4-30 Class A Edition 3 standards
  • Log up to five-hundred parameters simultaneously and to a high accuracy
  • Harmonics for voltage and current
  • Interharmonics for voltage and current
  • Unbalance
  • Flicker
  • Rapid voltage changes
  • Measure neutral current and all three current and voltage phases (using three-phase and neutral voltage test leads, and flexible current probes)
  • Can capture events whilst logging parameters
  • Record event waveforms
  • Determine an RMS event profile including the date, time and severity information
  • Identify root causes of power quality issues
  • Assess power quality in accordance with EN 50160 and IEEE 519 whether testing at the service entrance, substation or at the load
  • Ensures that measurement trends are complete by automatically logging a variety of power quality and power variables
  • Download data to a USB drive
  • Transfer data via a wired, Wi-Fi or Ethernet connection
  • Two USB ports
  • Wi-Fi connectivity allows the user to view data remotely and in real-time outside of hazardous areas
  • Supplied with Fluke’s Energy Analyse Plus Software
  • View data remotely and in real-time using the supplied software and a Wi-Fi connection
  • Create EN 50160, IEEE 519, GOST 33073 reports using the Fluke Energy Analyse Plus Software
  • Adjust report templates as standards evolve
  • Export data in PQDIF or NeQual formats using the Fluke Energy Analyse Plus Software
  • Analyse every detail of the energy consumption and power-quality state of health
  • Customise the data view as necessary when using the Fluke Analyse Plus Software
  • The Fluke Energy Plus Software calculates the limits of the current harmonics allowing it to predict grid overload in accordance with a variety of international standards
  • Quick, guided, graphical PC-based application setup
  • Intelligent verification feature ensures the connections are correct
  • Intelligent verification feature digitally corrects connections without the user having to disconnect test leads and/or clamps
  • A connection error is indicated by an amber light
  • A green light indicates a good connection
  • Automatically detects, scales and powers the connected probe
  • Current probes are connected separately for maximum flexibility
  • Can be powered by the circuit-under-investigation
  • Wide power range
  • Automatically goes from 100V to 500V
  • Lithium-ion battery with an operating time of four hours per charge
  • Safety rating: 600V CAT IV/ 1000V CAT III
  • Can be used at the service entrance and downstream
  • Small size: 23cm x 18cm x 5.4cm
  • Suitable for use in tight spaces
  • Supplied with a magnetic hanger
  • Rugged
  • IP65 ports
  • Can be secured using a chain or other security device
  • IP65, flexible, thin current probes (NOT supplied with the Fluke 1748/B/EUS model)
  • 2m test leads for accessing awkwardly placed conductors
  • Practical, portable and precise three-phase power logger

What’s Included

  • Your Choice of Fluke 1748/ EUS Three-Phase Power Quality Logger Kit (see below)
Items FLUKE1748/B/EUS FLUKE1748/15/EUS FLUKE1748/30/EUS
Fluke 1748/EUS Three-Phase Power Quality Logger 
1500A iFlex Current Probes (60cm) - -
3000A iFlex Current Probes (60cm) - -
USB Stick
USB Cable
3PHVL-1730 3-Phase + neutral voltage test lead
Test lead set red/black 0.18 m
Test lead set red/black 1.5 m
Alligator clips 4 4 4
173x/174x Soft Case
Cable marker kit
MP1-3R/1B-Magnet Probe 1 set (3 red, 1 black) 1 1 1
174x-Hanger Kit
FREE Powerbank / Wireless Charger
  • PASS Power Bank & Magnetic Wireless Charger (10 000mAh 15W) - PASSPOWER-PLUS, typically £49.00

Fluke 174X Three-Phase Power Quality Loggers Technical Specifications 

Please note that the Fluke 1748/ EUS Three-Phase Power Quality Loggers are part of Fluke's range of 174X Three-Phase Power Quality Loggers; the table below details the technical specifications for all the models included in this range. 

Specifications
Accuracy
Parameter Range Maximum Resolution Intrinsic Accuracy at Reference Conditions (% of Reading +% of Range)
Voltage 1000 V 0.1 V ±0.1 % of nominal voltage 1, 2
Current: Direct input i17xx-flex 1500IP 24 1500 A 150 A 0.01 A (min. 1.5A)3 ±(1% + 0.02%)
1500 A 0.1 A
i17xx-flex 3000IP 24 3000 A 300 A 0.01 A (min. 3.0 A)3 ±(1% + 0.03%)
3000 A 0.1 A
i17xx-flex 6000IP 36 6000 A 600 A 0.01 A (min. 6.0 A)3 ±(1.5% + 0.03%)
6000 A 0.1 A
i40s-EL clamp 4 A 1 mA ±(0.7% + 0.02%)
40 A 10 mA
Frequency 42.5 Hz to 69 Hz 0.01 Hz ±(0.1%)2
Auxiliary input ±10 V dc 0.1 mV ±(0.2% + 0.02%)
Voltage min/max 1000 V 0.1 V ±0.2 % of nominal input voltage1
Current min/max Defined by accessory Defined by accessory ±(5% + 0.2%)
THD on voltage 1000% 0.10% ± 2.5%
THD on current 1000% 0.10% ± 2.5%
Voltage harmonics 2nd to 50th 1000 V 0.1 V ≥ 1 V: ±5% of reading
< 1 V: ±0.05V
Current harmonics 2nd to 50th Defined by accessory Defined by accessory ≥ 3% of current range: ±5% of reading
< 3% of current range: ±0.15% of range
Flicker PLT, PST 0 to 20 0.01 5%
Current probe accuracy
Parameter Influence quantity/ iFlex1500IP-24 iFlex3000IP-24  iFlex6000IP-36 i40S-EL
150 A / 1500 A 300 A / 3000 A 600 A / 6000A 4 A / 40 A
Active Power P PF ≥ 0.99 1.2% + 0.005% 1.2% + 0.0075% 1.7% + 0.0075% 1.2% + 0.005%
Active Energy Ea
Apparent power S 0 ≤ PF ≤ 1 1.2% + 0.005% 1.2% + 0.0075% 1.7% + 0.0075% 1.2% + 0.005%
Apparent Energy Eap
Reactive power Q 0 ≤ PF ≤ 1 2.5% of measured apparent power
Reactive Energy Er
Power Factor PF - ±0.025
Displacement Power
Factor DPF/cosΦ
Additional uncertainty in% of range VP-N>250 V 0.015% 0.023% 0.023% 0.015%
1 In the range of 100 V … 500 V; also known as Udin
2 0 °C … 45 °C: Intrinsic accuracy x 2, outside of 0 °C … 45 °C: Intrinsic accuracy x 3
3 Consult operators manual for details

Reference conditions:
Environmental: 23 °C ± 5 °C, instrument operating for at least 30 minutes, no external electrical/magnetic field, RH <65 %
Input conditions: Cosφ/PF=1, Sinusoidal signal f=50 Hz/60 Hz, power supply 120 V/230 V ±10 %.
Current and power specifications: Input voltage 1 ph: 120 V/230 V or 3 ph wye/delta: 230 V/400 V
Input current: I > 10 % of I range
Primary conductor of clamps or Rogowski coil in center position
Temperature coefficient: Add 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C
Electrical Specifications
Power Supply
Voltage range 100 V to 500 V using safety plug input when powering from the measurement circuit
100 V to 240 V MA-C8 and using standard power cord (IEC 60320 C7)
Power consumption Maximum 50 VA (max. 15 VA when powered using MA-C8 adapter)
Efficiency ≥ 68.2% (in accordance with energy efficiency regulations)
Maximum no-load consumption < 0.3 W only when powered using IEC 60320 input
Mains power frequency 50/60 Hz ±15%
Battery Li-ion 3.7 V, 9.25 Wh, customer-replaceable
On-battery runtime Typically 4 hours
Charging time < 6 hours
Data Acquisition
Resolution 16-bit synchronous sampling
Sampling frequency 10.24 kHz at 50/60 Hz, synchronized to mains frequency
Input signal frequency 50/60 Hz (42.5 to 69 Hz)
Circuit types 1-Φ, 1-Φ IT, split phase, 3-Φ delta, 3-Φ wye, 3-Φwye IT, 3-Φ wye balanced, 3-Φ Aron/Blondel (2-element delta), 3-Φ delta open leg, currents only (load studies)
Data storage Internal flash memory (not user replaceable)
Memory size Typical 20 logging sessions of 4 weeks with 1-minute intervals and 500 events
Basic Interval
Measured parameters Voltage, current, aux, frequency, THD V, THD A, power, power factor, fundamental power, DPF, energy
Averaging interval User selectable: 1 sec, 5 sec, 10 sec, 30 sec, 1 min, 5 min, 10 min, 15 min, 30 min
Averaging time min/max values Voltage, Current: Full cycle RMS updated every half cycle (URMS1/2 according to IEC61000-4-30 Aux, Power: 200ms)
Demand Interval (Energy Meter Mode)
Measured parameters Energy (Wh, varh, VAh), PF, maximum demand, cost of energy
Interval User selectable: 5 min, 10 min, 15 min, 20 min, 30 min, off
Power Quality Measurements
Measured parameter Voltage, frequency, unbalance, voltage harmonics, THD V, current, harmonics, THD A, TDD, voltage interharmonics, TID V, current interharmonics, TID A, Flicker, Mains Signaling, under/over deviation
Averaging interval 10 min for all parameters
2 hrs (long term Flicker PLT)
150/180 cycles (3 s) for harmonics (requires software license IEEE519/REPORT)
Individual harmonics 2nd to 50th harmonic
Grouping according to IEC 61000-4-7 user configurable depending on application: Sub-grouped (harmonics + interharmonics), grouped or harmonic bins only
Interharmonics 1st to the 50th interharmonic
Total harmonic distortion Calculated on 50 voltage harmonics
Events Voltage: dips, swells, interruptions, current: inrush current
1748: mains signaling, transients (low frequency)
Triggered recordings RMS profile: Full cycle RMS updated every half cycle of voltage and current up to 11 s (URMS1/2 according to IEC 61000-4-30)
Waveform of voltage and current up to 200 ms, 10/12 cycles
Mains signaling: 10/12 cycle RMS recording of the configured frequencies up to 120s
Inrush RMS profile based on 1/2 cycle RMS steady state triggering
Flicker In accordance with IEC 61000-4-15 and IEEE 1453
Mains signaling Two user defined frequencies up to 3 kHz
PQ Health Summarizes power quality measurements in one table. Detailed data available for each parameter
EN 50160 Compliance with standard
Programmable PQ limits Enables user defined limits for local standards compliance
Standards Compliance
Harmonics IEC 61000-4-7: Class 1
IEEE 519 (short time and very short time harmonics)
Power quality IEC 61000-4-30 Class A, IEC 62586-1, IEC 62586-2 (PQI-A-PI device)
Power IEEE 1459
Power quality compliance EN 50160
Safety General: IEC 61010-1: Pollution Degree 2
Measurement: IEC 61010-2-033: CAT IV 600 V / CAT III 1000 V
Power Supply: Overvoltage Category IV, Pollution Degree 2
Li-ion Battery: IEC 62133
Interfaces
USB-A File transfer via USB flash drive, firmware updates, max. supply current: 120 mA
WiFi File transfer and remote control via direct connection or WiFi infrastructure
Bluetooth Read auxiliary measurement data from Fluke Connect® 3000 series modules (requires supported USB to BLE or WiFi/BLE adapter, check for availability)
USB-mini Data download device to PC
Current Inputs
Number of inputs 4 (3 phases and neutral), mode selected automatically for attached sensor
Input voltage Clamp input: 500 mVrms/50 mVrms; CF 2.8
Rogowski coil input: 150 mVrms/15 mVrms at 50 Hz, 180 mVrms/18 mVrms at 60 Hz; CF 4 all at nominal probe range
Range 1 A to 150 A/10 A to 1500 A with thin flexible current probe i17XX-flex1500 IP 24
3 A to 300 A/30 A to 3000 A with thin flexible current probe i17XX-flex3000 IP 24
6 A to 600 A/60 A to 6000 A with thin flexible current probe i17XX-flex6000 IP 36
40 mA to 4 A/0.4 A to 40 A with 40 A clamp i40s-EL
Bandwidth 42.5 Hz - 3.5 kHz
Scaling 1:1 and variable
Auxiliary Inputs
Number of inputs 2 (Analog with auxiliary adapter, or up to 2 BLE devices simultaneously)
Input range 0 to ± 10 V dc, or 0 to ± 1000 V dc (with optional adapter), 1 reading/s
Scale factor Format: mx + b (gain and offset) user configurable
Displayed units User configurable (7 characters, for example, °C, psi, or m/s)
Wireless Bluetooth connection (check for availability)
Number of inputs 2
Supported modules Fluke Connect® 3000 series
Acquisition 1 reading/s
Environmental Specifications
Operating temperature -25 °C to +50 °C (-13 °F to 122 °F)1
Storage temperature Without battery: -25 °C to +60 °C (-13 °F to 140 °F), with battery: -20 °C to +50 °C (−4 °F to 122 °F)
Operating humidity IEC 60721-3-3: 3K6:
-25 °C to +30 °C (-13 °F to +86 °F): ≤ 100 %
40 °C (104 °F): 55 %
50 °C (122 °F): 35 %
Operating Altitude 2000 m (up to 4000 m derate to 1000 V CAT II/600 V CAT III/300 V CAT IV)
Storage altitude 12,000 m
Enclosure IEC 60529: IP50
IEC 60529: IP65 with IP65 rated voltage connector
Vibration IEC 60721-3-3 / 3M2
Electromagnetic compatibility (EMC) EN 61326-1: Industrial CISPR 11: Group 1, Class A
IEC 61000-6-5 Power station environment
Korea (KCC): Class A Equipment (industrial broadcasting and communication equipment)
USA (FCC): 47 CFR 15 subpart B. This product is considered an exempt device per clause 15.103
General Specifications
Warranty Two-years (battery not included)
Accessories: one-year
Calibration cycle: two-years
Dimensions 23.0 cm x 18.0 cm x 5.4 cm (9.1 in x 7.1 in x 2.1 in)
Weight Instrument: 1 kg (2.2 lb)
Tamper protection Accept securing cables (max. Φ 6mm)
1Warm up the product to -10 °C (+14 °F) before you power the unit on
Flexible Current Probe Specifications
Specifications  i17XX-FLEX1.5KIP i17XX-FLEX3KIP
Measuring range 1 to 150 A ac/10 to 1500 A ac 1 to 300 A ac 10 to 3000 A ac
Probe cable length 610 mm (24 in) 610 mm (24 in)
Probe cable diameter 7.5 mm (0.3 in) 7.5 mm (0.3 in)
Weight 170 g (0.38 lb) 170 g (0.38 lb)
Minimum bending radius 38 mm (1.5 in)
Nondestructive current 100 kA (50/60 Hz)
Temperature coefficient over
operating temperature range
0.05 % of reading/°C (0.028 % of reading/°F)
Working voltage 1000 V CAT III, 600 V CAT IV
Output cable length 2.0 m (6.5 ft)
Probe cable material TPR
Weight 115 g
Probe cable material TPR
Coupling material POM + ABS/PC
Output cable TPR/PVC
Operating temperature -20 °C to +70 °C (-4 °F to 158 °F) temperature of conductor under test shall not exceed 80 °C (176 °F)
Temperature, non-operating -40 °C to +80 °C (-40 °F to 176 °F)
Relative humidity, operating 15% to 85% non-condensing
IP rating IEC 60529: IP65
Warranty One-year

Fluke 174X Three-Phase Power Quality Loggers Comparison Table

Functions  1742 Power Quality Loggers 1746 Power Quality Loggers 1748 Power Quality Loggers
Voltage, current, power, power factor, frequency X X X
Energy forward/reverse X X X
Peak Demand X X X
THD X X X
Voltage and current harmonics (to 50th)1 X X
Flicker X X X
Unbalance1 X X
Rapid voltage change events1 X X
Interharmonics (to 50th)1 X X
Dips, swells, interruption and transient events tables1 X X
Mains signaling X X
Inrush current1  X X
Transients (low frequency)/Waveform deviation events2 X
Recording  1742 Power Quality Loggers 1746 Power Quality Loggers 1748 Power Quality Loggers
Trend X X X
Waveform snapshots2 X
RMS profile2 X
Communication  1742 Power Quality Loggers 1746 Power Quality Loggers 1748 Power Quality Loggers
Ethernet X X X
USB (mini B) X X X
WiFi download Instrument to device X X X
Wifi download via WiFi hub (requires registration) Opt Opt Opt
Included accessories 1742 Power Quality Loggers 1746 Power Quality Loggers 1748 Power Quality Loggers
Flexible current probe not /B version not /B version not /B version
USB stick X X X
USB cable X X X
3PHVL-1730 3-Phase + neutral voltage test lead X X X
Test lead set red/black 0.18 m X X X
Test lead set red/black 1.5 m X X X
Alligator clips 4 4 4
173x/174x Soft Case X X X
Cable marker kit X X X
MP1-3R/1B-Magnet Probe 1 set (3 red, 1 black) Opt 1 1
174x-Hanger Kit Opt Opt X

Fluke 174X Three-Phase Power Quality Logger - Datasheet Datasheets Fluke 174X Three-Phase Power Quality Logger - IEC 61000-4-30 Class A Standard Explained Manuals & Guides Fluke 174X Three-Phase Power Quality Logger - Fluke Connect and Wi-Fi Instructions Manuals & Guides Fluke 174X Three-Phase Power Quality Logger - User Manual Supplement Manuals & Guides Fluke 174X Three-Phase Power Quality Logger - Calibration Manual Manuals & Guides Fluke 174X Three-Phase Power Quality Logger - User Manual Manuals & Guides Fluke 174X Three-Phase Power Quality Logger - Quick Reference Guide Manuals & Guides Fluke 174X Three-Phase Power Quality Logger - Overhead Lines Application Note Case Studies & Applications Fluke 174X Three-Phase Power Quality Logger - Downloading, Analysing and Reporting Application Note Case Studies & Applications Fluke 174X Three-Phase Power Quality Logger - Statement of Memory Volatility Notes & Other Fluke 174X Three-Phase Power Quality Logger - Safety Information Notes & Other

Reviews

Additional Information
SKU Fluke/1748/EUS
Manufacturer Part Code 4920780