Free Beanie Hat. Spend £250+ (ex VAT) View
All Fluke Calibration Products

Fluke 1586A/DS-HC Super DAQ w/ 1 High-Capacity Module & 1 Multiplexer

SKU
Fluke 1586A/DS-HC
Rating:
0%
(0)
Reward Points
:
5827
£5,827.20 £4,856.00
Made to Order
Free UK Delivery*
Advice & Support Call 01642 931329 or contact us
Price Match We won't be beaten, let us know
Free Aftersales Support
Fluke DAQ-STAQ Multiplexer

The Fluke 1586A/DS-HC Super DAQ with 1 High-Capacity Module & 1 Multiplexer consists of three products:

  • 1x Fluke 1586A Super DAQ
  • 1x Fluke 1586-2586 High-Capacity Module
  • 1x Fluke DAQ-STAQ Multiplexer

For further information regarding these products, please see the video below.

1586A Super-DAQ Introduction Video

The Fluke 1586A/DS-HC Super DAQ with 1 High-Capacity Module & 1 Multiplexer is available in two variations which differ only in regards to the mains voltage setting. For further information, please see the following table.

Product Code Product Name  Mains Voltage Settings
1586A/DS-HC 220 Fluke 1586A/DS-HC 220 Super-DAQ with 1 High Capacity Module & 1 DAQ-STAQ Multiplexer 220V: 198V to 242V
1586A/DS-HC 240 Fluke 1586A/DS-HC 240 Super-DAQ with 1 High Capacity Module & 1 DAQ-STAQ Multiplexer 240V: 216V to 264V

The Fluke 1586A Super DAQ can function as a data-logger, multimeter and temperature calibrator. It can be used with the included high-capacity module and multiplexer to facilitate these extensive measurement capabilities.

The Fluke 1586-2586 High-Capacity Module makes the Fluke 1586A Super DAQ suitable for factory applications. The module can be configured to accommodate the necessary inputs for particular tests and can facilitate the data acquisition system’s ability to measure thermocouples, RTDs, voltage, resistance and current simultaneously. The Fluke 1586-2586 High-Capacity Module can be fitted into the Fluke 1586A Super DAQ as necessary and may be used interchangeably with other high-capacity modules. Test setups for each high-capacity module can be recalled from the Fluke 1586A Super DAQ’s extensive memory. This module’s adaptability and the Fluke 1586A Super DAQ’s ability to store and recall test setups improves testing efficiency as the need to re-wire and re-configure inputs are removed.

Alternatively, the Fluke 1586A Super DAQ can be used with the included Fluke DAQ-STAQ Multiplexer to perform benchtop temperature calibrations in calibration laboratories. It can be easily stacked on top of the Fluke 1586A Super DAQ and includes a variety of input terminals designed to facilitate a connection between the Fluke 1586A Super DAQ and thermistors, thermocouples and PRTs. It includes mini-jack thermocouple terminals with reference junction sensors, as well as mini-DWF, gold-plated input terminals compatible with bare wire, spade lug and mini-banana-plug terminations.

It is possible to use multiple Fluke DAQ-STAQ Multiplexers with the Fluke 1586A Super DAQ in order to measure the temperature, DC voltage, DC current and resistance for up to forty channels. The Fluke 1586A Super DAQ may be set to scan these channels at a rate of up to ten channels per second. In addition to this, the Fluke 1586A Super DAQ features an Alarm function allowing the user to set upper- and lower-limit alarms for each active channel. These features improve the efficiency of testing and allow the user to tailor the instrument to the application.

Alternatively, the Fluke 1586A Super DAQ can be used with Fluke’s Dry Wells or Fluid Calibration Baths to perform sensor calibrations. The data acquisition system includes a function optimised for this purpose, the Automated Sensor Calibration function. Once the following specifications (see below) have been entered into the Fluke 1586A Super DAQ’s setup, the data acquisition system and connected Fluke instrument are able to perform a comprehensive sensor calibration unsupervised, freeing the user to perform other tasks in the meantime, thereby improving his/her work efficiency. The specifications required for this function include:

  • Number of temperature setpoints
  • Values of the temperature set points
  • Scan sequence (choose between linear, alternate or up/down)
  • Assign a reference channel
  • Set the required stability band

The Fluke 1586A Super DAQ uses the reference channel to determine when the temperature source is stable. Once temperature stability has been determined the Fluke 1586A Super DAQ will gather the necessary readings before moving on to the next temperature setpoint.

The Fluke 1586A Super DAQ is able to measure PRTs to an accuracy of ±0.005°C when used with the included Fluke DAQ-STAQ Multiplexer. It is also capable of measuring thermocouples to an accuracy of ±0.5°C when used with the Fluke 1586-2586 High-Capacity Module and can measure thermistors to an accuracy of ±0.002°C. To maintain this accuracy, the Fluke 1586A Super DAQ includes a Channel Offset Zero function and a current reversal feature designed to limit the effects of thermoelectricity and thereby improve the accuracy of PRT/RTD measurements.

In addition to the above features and functions, the Fluke 1586A Super DAQ includes a MAX + B function, as well as the following measurement modes:

  • Scan: scan through the channels according to user-defined tests
  • Monitor: monitor a single channel throughout a scan without disturbing the process
  • Measure: measure and record data for a single channel without a pre-configured test file
  • DMM (digital multimeter): use the Fluke 1586A Super DAQ’s front panel to measure DC voltage, DC current and 2-wire/ 4-wire resistance without having to configure the channels

This instrument also includes a Historical mode which allows the user to view saved data contained within a scan file. This data can be displayed in a tabular or graphical format on the Fluke 1586A’s colour display with a 6.5-digit resolution.

Similarly, real-time data may also be displayed in a tabular or graphical format and the user is able to switch between these display settings as necessary. When data is displayed in a tabular format the user is able to view all the readings for all the active channels. Alternatively, he/she can view data plotted in real-time for up to four channels when the Fluke 1586A Super DAQ is set to display data in a graphical format. This setting allows the user to monitor trends as well as zoom in and out on data points. These comprehensive data display capabilities remove the need for a PC or charting programs when reviewing test setups or conducting data analysis.

Nevertheless, the Fluke 1586A is compatible with Fluke’s TQSoft and TQAero Thermal Validation Software (NOT included). This software can be used to document results, create reports and provide complete qualification. These programs can also be used as audit trail management systems, making them suitable for use in applications regulated by governmental and/or agency standards.

The Fluke 1586A Super DAQ is also designed to be suitable for applications regulated by governmental and/or agency standards as it includes two levels of data security. These prevent unauthorised access to stored data, thereby maintaining data-traceability.

This instrument has an extensive 20MB, internal, non-volatile memory with the capacity to store up to 75 000 time-stamped readings. This information may be transferred to a PC via a USB flash drive or a network with LAN interface connection. Once transferred to a PC, measurements can be viewed in a Microsoft Excel file.

The Fluke 1586A Super DAQ is a comprehensive, versatile and sophisticated data acquisition system, it can be used with the included Fluke DAQ-STAQ Multiplexer and Fluke 1586-2586 High-Capacity Module to perform a variety of applications, including:

  • Process sensor calibration
  • Temperature validation
  • Thermal mapping
  • Verifying process control
  • Analysing interactive systems
  • Ensuring conformance to quality standards
  • Correlating related events for R&D or troubleshooting

These extensive testing and measurement capabilities combined with the Fluke 1586A/DS-HC Super DAQ with 1 High-Capacity Module & 1 Multiplexer’s adaptability and practicality, makes this selection of products ideal for technicians, engineers and quality control personnel working in the pharmaceutical, food processing, aerospace and automotive industries.

Fluke 1586A/DS-HC Super DAQ w/ 1 High-Capacity Module & 1 Multiplexer Key Features

  • Consists of three products: 1x Fluke 1586A Super DAQ; 1x Fluke 1586-2586 High-Capacity Module and 1x Fluke DAQ-STAQ Multiplexer
  • Available in two variations which differ in regards to their mains voltage settings
  • Functions as a data-logger, multimeter and temperature calibrator
  • Use the Fluke 1586A Super DAQ with the Fluke 1586-2586 High-Capacity Module for factory applications
  • High-capacity module can be configured to accommodate the necessary inputs for a variety of tests
  • High-capacity module can be used to measure thermocouples, RTDs, voltage, resistance and current
  • High-capacity modules can be used interchangeably
  • Test setups for high-capacity modules can be recalled from the Fluke 1586A Super DAQ’s memory
  • High-capacity module can be used to improve testing efficiency
  • Use the Fluke 1586A Super DAQ with the Fluke DAQ-STAQ Multiplexer to perform benchtop temperature calibration
  • Stack the Fluke DAQ-STAQ Multiplexer on top of the Fluke 1586A Super DAQ
  • Multiplexer facilitates a connection between the Super DAQ and thermocouples, thermistors and PRTs
  • Multiplexer includes mini-thermocouple terminals with reference junction sensors
  • Multiplexer includes mini-DWF, gold-plated input terminals compatible with bare wire, spade lug and mini-banana-plug terminations
  • Use the Multiplexer with the Super DAQ to measure temperature, DC voltage, DC current and resistance for up to forty channels (additional multiplexers needed)
  • Scan channels at a sample rate of up to ten channels per second
  • Alarm function – set an upper- and lower-limit alarm for each active channel
  • Fluke 1586A Super DAQ can be used with Fluke’s Dry Wells or Fluid Calibration Baths to perform sensor calibrations
  • Automated Sensor Calibration function
  • Use the Fluke 1586A Super DAQ with the Fluke DAQ-STAQ Multiplexer to measure PRTs to an accuracy of ±0.005°C
  • Use the Fluke 1586A Super DAQ with the Fluke 1586-2586 High-Capacity Module to measure thermocouples to an accuracy of ±0.5°C
  • Use the Fluke 1586A Super DAQ to measure thermistors to an accuracy of ±0.002°C
  • Channel Offset Zero function
  • Current reversal feature limits thermoelectric effects thereby improving the accuracy of PRT/RTD measurements
  • MAX + B function
  • Scan mode
  • Monitor mode
  • Measure mode
  • DMM mode
  • Colour display with a 6.5-digit resolution
  • Historical mode – allows the user to view data saved to scan files
  • Two display formats: tabular or graphical
  • Tabular format: view all the data for all the active channels
  • Graphical format: plots and displays data for up to four channels in real-time
  • The user is able to monitor trends and zoom in and out on data points when the Fluke 1586A Super DAQ is set to display data in a graphical format
  • Comprehensive display settings remove the need for a PC or charting software when reviewing test setups or performing data analysis
  • Compatible with Fluke’s TQAero and TQSoft Thermal Validation Software (NOT included)
  • Suitable for applications regulated by governmental and/or agency standards
  • Two levels of data security optimised to prevent unauthorised access to stored data
  • Data security maintains data-traceability
  • 20MB, internal, non-volatile memory – capacity for 75 000 time-stamped readings
  • Transfer data to a PC using a USB flash drive or via a network with a LAN interface connection
  • View data in a Microsoft Excel file
  • Comprehensive, versatile and sophisticated data acquisition system
  • Adaptable and practical
  • Suitable for process sensor calibration
  • Suitable for temperature validation
  • Can be used for thermal mapping
  • Can be used to verify process control
  • Ideal for analysing interactive systems
  • Idea for ensuring conformance to quality standards
  • Can be used to correlate related events for R&D or troubleshooting
  • Ideal for technicians, engineers and quality control personnel
  • Suitable for applications in the pharmaceutical, food processing, aerospace and automotive industries

What’s Included?

Your choice of Fluke 1586A/DS-HC Super DAQ w/ 1 High-Capacity Module & 1 Multiplexer consisting of:

  • 1x Fluke 1586A Super DAQ
  • 1x Fluke 1586-2586 High-Capacity Module
  • 1x Fluke DAQ-STAQ Multiplexer

Fluke 1586A/DS-HC Super DAQ w/ 1 High-Capacity Module & 1 Multiplexer Technical Specifications 

Please find below the general technical specifications for the Fluke 1586A Super DAQ, Fluke 1586-2586 High-Capacity Module and Fluke DAQ-STAQ Multiplexer. For more detailed specifications, please see the 'Extended Specifications' datasheet. 

Fluke 1586A Super DAQ Technical Specifications 

Mains Voltage  220V Model: 198 V to 242 V
240V Model: 216 V to 264 V
Frequency 47 Hz to 440 Hz
Power Consumption  36 VA peak (24 W average)
Environment Temperature Operating: 0 °C to 50 °C
Full accuracy: 18 °C to 28 °C
Storage: −20 °C to 70 °C
Warm-up: 1 hour to full accuracy specifications
Relative Humidity (non-condensing) Operating:  0 °C to 30 °C <80 %;
                   30 °C to 50 °C <50 %
Storage: −20 °C to 70 °C <95 %
Altitude Operating:  2,000 m
Storage: 12,000 m
Vibration and Shock  Complies with MIL-PRF-28800F Class 3
Channel Capacity Total analog channels: 45
Voltage/resistance channels: 41
Current channels:  5
Digital I/O: 8 bits
Totalizer: 1
Alarm outputs: 6
Trigger input: 1
Channel Input Connector Types 1586A Channel 001 (front panel): gold pins, bare wire, spade lugs, banana plugs
High-Capacity Module: gold pins, bare wire
Input Protection  50 V all functions, terminals and ranges
Math Channels Number of channels: 20
Operations: sum, difference, multiply, divide, polynomial, power, square root, reciprocal, exponential, logarithm, absolute value, average, maximum, minimum
Triggers interval, external (trigger input), alarm, remote (bus), manual, automated test
Memory Scan data RAM: 75,000 readings with timestamp
Data/Setup flash memory: 20 MB
USB Host Port Connector type: Type A
Function: Memory
File system: FAT32
Memory capacity: 32 GB
USB Device Port Connector type: Type B
Class: Instrument
Function: Control and data transfer
Command protocol: SCPI
LAN Function: Control and data transfer
Network protocols: Ethernet 10/100, TCP/IP
Command protocol: SCPI
RS-232 Connector: D-sub 9 pin (DE-9)
Baud rates: 1200, 2400, 4800, 9600, 19200, 38400
Function: Temperature source control output
Dimensions Height: 150 mm
Width: 245 mm
Depth: 385 mm Weight: 6 kg (typical configuration)
Shipping Weight: 9.5 kg (typical configuration)
Conformity CE, CSA, IEC 61010 3rd ed.

Fluke 1586-2586 High-Capacity Module Technical Specifications 

Maximum Input 50 V
Offset Voltage <2 μV
3-Wire Internal Resistance Mismatch  <50 mΩ
Basic CJC Accuracy  0.6 °C

Fluke DAQ-STAQ Multiplexer Technical Specifications 

Maximum Input 50 V
Offset Voltage <2 μV
3-Wire Internal Resistance Mismatch  <50 mΩ
Basic CJC Accuracy  0.25 °C
Fluke 1586A Super DAQ - Datasheet Datasheets Fluke 1586A Super DAQ - Calibration Manual Manuals & Guides Fluke 1586A Super DAQ - Calibration Manual Supplement Manuals & Guides Fluke 1586A Super DAQ - User Manual Supplement Manuals & Guides Fluke 1586A Super DAQ - Remote Programmer's Guide Manuals & Guides Fluke 1586A Super DAQ - User Manual Manuals & Guides Fluke 1586A Super DAQ _ Automating Temperature Calibration Step-by-Step Guide Manuals & Guides Fluke 1586A Super DAQ - Extended Specifications Technical Specifications Fluke 1586A Super DAQ - Safety Information Supplement Notes & Other Fluke 1586A Super DAQ - Safety Information Notes & Other

Reviews

Additional Information
SKU Fluke 1586A/DS-HC
Manufacturer Part Code 4410092

Made to Order item: This item is made-to-order with a lead time once the order is placed. Once an order is placed it cannot be cancelled or returned unless the unit is found to be faulty.