Free Beanie Hat. Spend £250+ (ex VAT) View
All Fluke Calibration Products

Fluke 1552A-12 Calibration Stik Thermometer

SKU
1552A-12
Rating:
0%
(0)
Reward Points
:
1324
£1,588.80 £1,324.00
Made to Order
Free UK Delivery*
Advice & Support Call 01642 931329 or contact us
Price Match We won't be beaten, let us know
Fluke 1552A-12 Calibration Stik Thermometer

The Fluke 1552A-12 Calibration Stik Thermometer has the following probe dimensions: 6.35mm x 305mm (diameter x length). It can be used to measure temperatures between -80°C to 300°C. This instrument has an accuracy of ±0.05°C across its full range making it suitable for conducting measurements in process manufacturing plants for chemicals, pharmaceuticals, food or petroleum products, where inaccuracies of temperature can cause erroneous volumetric measurements.

The accuracy specification supplied with this instrument accounts for a number of uncertainties, including drift, for up to a year. This ensures that the displayed temperature is the accurately measured temperature and removes the need for the user to conduct additional calculations to account for variables, as may be the case with mercury-in-glass thermometers.

Furthermore, unlike with mercury thermometers, the Fluke 1552A-12 Calibration Stik Thermometer does not require the external conditions to match its original calibration conditions in order for it to conduct precise temperature measurements.

The Fluke 1552A-12 Calibration Stik Thermometer is calibrated as a single system (i.e. the probe and readout unit are calibrated together) and is supplied with an NVLAP-accredited and NIST-traceable calibration. This instrument can be easily recalibrated using its three-point calibration function.

Moreover, not only is this instrument’s thin-film RTD sensor more resilient than a traditional mercury thermometer (there are no risks of mercury spills using this temperature tester), it also doesn’t require as deep an immersion depth, needing only 7cm / 2.8” to conduct precise temperature measurements. Additionally, the accuracy of these measurements is not compromised by heat loss caused by stem conduction.

Once the temperature source has reached a suitable stability the Fluke 1552A-12 Calibration Stik Thermometer’s stability indicator will alert the user, allowing him/her to conduct an accurate and reliable temperature reading. Prior to the temperature source attaining stability, this indicator will also show which way it is trending (rising or falling).  

The user is able to view temperature readings in °C or °F and in a resolution of 0.1°, 0.01° or 0.001°. Temperatures are visible via the backlit, LCD display which may be rotated up to 90° in order to ensure the measurement is always viewable.

Adding to this instrument’s practicality is the inclusion of an Auto-Power-Off function which can be engaged to prolong the Fluke 1552A-12 Calibration Stik Thermometer’s battery life for up to 300 hours. Moreover, this instrument’s low battery indicator and stop-measure function prevent the user from conducting inaccurate and/or unreliable measurements as a result of low battery power.

Finally, the Fluke 1552A-12 Calibration Stik Thermometer is intrinsically safe. It is compliant with ATEX and IECEx specifications. This instrument serves as a reliable, accurate and practical alternative to traditional mercury thermometers. Its compact, portable design makes it suitable for use across a variety of environments. The Fluke 1552A-12 Calibration Stik Thermometer is suitable for use outside, in areas where explosive gases may be present, and in processing plants.

Fluke 1552A-12 Calibration Stik Thermometer Key Features

  • Measure temperatures between -80°C and 300°C
  • Probe dimensions: 6.35mm x 305mm (diameter x length)
  • Accuracy of ±0.05°C across its full range
  • Suitable for conducting measurements in process manufacturing plants
  • Accuracy specification accounts for uncertainties, such as drift, for a year
  • Removes the need for the user to conduct additional calculations to account for uncertainties
  • The displayed temperature is the accurately measured temperature
  • Does not require external conditions to match the original calibration conditions in order to measure temperatures accurately
  • Calibrated as a single system (i.e. the probe and display unit are calibrated together)
  • Supplied with an NVLAP-accredited and NIST-traceable calibration
  • Three-point calibration function for easy recalibration
  • Thin-film RTD sensor is more resilient than a mercury thermometer – no risk of mercury spillage
  • Only requires an immersion depth of 7cm/ 2.8” for accurate measurements
  • The accuracy of measurement is not compromised by heat loss caused by stem conduction
  • Stability indicator will display when the temperature source is stable
  • Prior to the temperature source attaining stability, the stability indicator will display which way the temperature source is trending (up or down)
  • View temperatures in either °C or °F
  • User-settable resolution: 0.1, 0.01 or 0.001°
  • Backlit, LCD display
  • Display unit is able to rotate up to 90°
  • The Auto-Power-Off function can be used to extend the instrument’s battery life for up to 300 hours
  • Low battery indicator and stop-measure function prevent the user from conducting inaccurate and/or unreliable measurements as a result of low battery power
  • Intrinsically safe
  • Complaint with ATEX and IECEx specifications
  • Reliable, accurate and practical alternative to mercury-in-glass thermometers
  • Compact, portable design
  • Suitable for use outside, in areas where explosive gases may be present, and in processing plants

What’s Included?

  • Fluke 1552A-12 Calibration Stik Thermometer
  • NVLAP-accredited Report of Calibration
  • User Guide on CD-ROM
  • 3x AAA Batteries

Fluke 1551A and 1552A Calibration Stik Thermometers Technical Specifications 

The Fluke 1552A-X Calibration Stik Thermometer is part of Fluke's series of 155XA Thermometers, please find below the technical specifications for these models. 

PLEASE NOTE the Fluke 1552A-12 Calibration Stik Thermometer does NOT have data-logging capabilities; a version of this thermometer with data-logging capabilities is available here. 

Specifications 1551A 1552A
Temperature range -50 °C to 160 °C 
(-58 °F to 320 °F)
-80 °C to 300 °C 
( -112 °F to 572 °F)
Accuracy (1 year) ± 0.05 °C (± 0.09 °F)
Display units °C, °F
Sensor type 100 Ω thin-film RTD 100 Ω wire-wound PRT
Probe temperature coefficient 0.00385 Ω/Ω/°C nominal
Sensor length ≤ 10 mm ≤ 30 mm
Sensor position (from sheath tip) 3 mm (0.1 in)
Minimum immersion depth 7 cm (2.8 in) 12 cm (4.8 in)
Probe sheath material Stainless steel
Response time 4.8 mm diameter probe (3/16 in): 14 seconds 
6.35 mm diameter probe (1/4 in): 21 seconds
Probe hysteresis ± 0.01 °C
Temperature resolution Selectable: 0.1, 0.01, 0.001 (default 0.01)
Sample rate Selectable: 0.5 seconds, 1 seconds, 2 seconds (default 1 seconds)
Operating temperature range readout -10 °C to 50 °C (14 °F to 122 °F)
Temperature resolution Selectable: 0.1, 0.01, 0.001 (default 0.01)
Sample rate Selectable: 0.5 seconds, 1 seconds, 2 seconds (default 1 seconds)
Operating temperature range readout -10 °C to 50 °C (14 °F to 122 °F)
Storage temperature -20 °C to 60 °C (-4 °F to 140 °F) 0 % to 95 % RH, non-condensing
Optional data logging1 Up to 10,000 time-stamped readings stored to internal memory
Logging intervals1 2 seconds, 5 seconds, 10 seconds, 30 seconds, or 60 seconds; 
2 minutes, 5 minutes, 10 minutes, 30 minutes, or 60 minutes
Damping Moving average of the most recent 2 to 10 readings 
(ON/OFF, 2, 5, 10)
Communications RS-232 stereo jack (access calibration parameters only)
AC power None
DC power 3-AAA Batteries, typical battery life of 300 hours without LCD backlight
EMC compliance EN61326:2006 Annex C; CISPR II Edition 5.0-2009; Class “B
Enclosure rating IP50
Electronics dimensions (H x W x D) 114 mm x 57 mm x 25 mm 
(4.5 in x 2.25 in x 1.0 in)
Weight 196 g (6.9 oz)
Calibration (included) NVLAP-accredited, NIST-traceable
Characterization CVD ITS-90
1See ordering information for optional data logging configurations
Fluke 1551A and 1552A Calibration Stik Thermometers - Datasheet Datasheets Fluke 1551A and 1552A Calibration Stik Thermometers - Instruction Sheet Manuals & Guides

Reviews

Additional Information
SKU 1552A-12
Manufacturer Part Code 3624151
Model Ref 1552A-12

Made to Order item: This item is made-to-order with a lead time once the order is placed. Once an order is placed it cannot be cancelled or returned unless the unit is found to be faulty.