Fluke 1551A-X Calibration Stik Thermometer

The Fluke 1551A-X Calibration Stik Thermometer can be used to measure temperatures between -50 and 160°C. It is available in three models that vary in regards to the length of their stainless steel probes; please see the table below for further information.

Product Code Product Name Probe Diameter Probe Length
1551A-9 Fluke 1551A-9 Calibration Stik Thermometer 4.8mm 229mm
1551A-12 Fluke 1551A-12 Calibration Stik Thermometer 6.35mm 305mm
1551A-20 Fluke 1551A-20 Calibration Stik Thermometer 6.35mm 508mm

The Fluke 1551A-X Calibration Stik Thermometer serves as a practical, intrinsically safe (ATEX and IECEx compliant) alternative to traditional mercury-in-glass thermometers. It is suitable for use outdoors, in areas where explosive gases may be present, and in processing plants. This makes it particularly useful to process manufactures of chemicals, pharmaceuticals, food, and petroleum products where inaccuracies in temperature can affect the accuracy of volumetric measurements.

Accuracy and reliability are at the forefront of this product’s design. It is supplied with an NVLAP- accredited and NIST-traceable calibration. The stainless steel probe and readout unit have been calibrated together and it includes a three-point calibration function allowing the user to recalibrate the Fluke 1551A-X Calibration Stik Thermometer quickly and easily.

This instrument has an accuracy of ±0.05°C over its full range; the specification includes all uncertainty components such as drift for up to one year. This ensures that the displayed temperature is the accurately measured temperature, removing the need for the user to carry out additional calculations to account for uncertainties, as is necessary with mercury thermometers.  Further to this, unlike with mercury thermometers, it is not necessary for external conditions to match the calibration conditions in order to ensure accurate measurements.

Moreover, the Fluke 1551A-X Calibration Stik Thermometer includes a stability indicator which alerts the user to when the temperature is suitably stable for recording an accurate temperature reading. This function will also indicate when the temperature source is trending upwards or downwards. The low-battery indicator and stop-measure function work to prevent the user from conducting inaccurate measurements caused by low battery power.

In addition to this, the Fluke 1551A-X Calibration Stik Thermometer includes a user-settable Auto-Off function which can be used to extend the longevity of this instrument’s battery life to up to 300 hours.

Temperatures can be viewed in either °C or °F and to a user-selectable resolution of 0.1, 0.01 or 0.001, thereby allowing the operator to tailor the thermometer to the application. Measurements are viewable via the backlit, LCD display which is able to rotate 90°, ensuring that it can always be easily seen.

Also adding to this instrument’s practicality, as well as its accuracy, is the inclusion of a thin-film RTD sensor which is at once both less susceptible to drift and more resilient than a mercury thermometer. The risk of mercury spills is completely eradicated with this thermometer.  

Furthermore, with the inclusion of this robust probe, the Fluke 1551A-X Calibration Stik Thermometer only requires an immersion depth of 7cm/ 2.8” and accuracy of measurement is not compromised by heat loss caused by stem conduction.

The Fluke 1551A-X Calibration Stik Thermometer is a practical, safe, accurate and reliable instrument. Its compact size and portability make it suitable for conducting temperature measurements in a variety of challenging environments.  

Fluke 1551A-X Calibration Stik Thermometer Key Features

  • Measure temperatures between -50 and 160°C
  • Available in three models that vary in regards to the length of their probes
  • Alternative to mercury-in-glass thermometers
  • ATEX and IECEx complaint
  • Suitable for use outdoors, in areas where explosive gases may be present, and in processing plants
  • Particularly useful to process manufactures of chemicals, pharmaceuticals, food or petroleum products
  • NVLAP-accredited and NIST-traceable calibration
  • Stainless steel probe and readout are calibrated as one system
  • Includes a three-point calibration function
  • Accuracy of ±0.05°C over its full range
  • Accuracy specification accounts for uncertainties such as drift, removing the need for additional calculations
  • It is not necessary for external conditions to match calibration conditions in order to conduct accurate measurements
  • Stability indicator
  • Trend indicator
  • Low-battery indicator
  • Stop-measurement function
  • User-settable Auto-Off function
  • Battery life can be extended to up to 300 hours
  • View temperatures in either °C or °F
  • User-selectable resolution: 0.1, 0.01 and 0.001°
  • Backlit, LCD display
  • The display can rotate 90°
  • Thin-film RTD sensor is less susceptible to drift and more resilient
  • Minimum immersion depth of 7cm/ 2.8”
  • Accuracy is not compromised due to heat loss caused by stem conductions
  • Portable and compact design
  • A practical, safe, accurate and reliable instrument
  • Suitable for conducting temperature measurements in a variety of environments

What’s Included?

  • Your Choice of Fluke 1551A-X Calibration Stik Thermometer
  • NVLAP-accredited Report of Calibration
  • User Guide on CD-ROM
  • 3x AAA Batteries

Fluke 1551A-X Calibration Stik Thermometer Technical Specifications

The Fluke 1551A-X Calibration Stik Thermometer has a sister product the Fluke 1552A-X Calibration Stik Thermometer; please find below the technical specifications for both models. 

PLEASE NOTE the Fluke 1151A-X Calibration Stik Thermometers do NOT have data-logging capabilities; versions of these thermometers with data-logging capabilities are available here. 

Specifications 1551A 1552A
Temperature range -50 °C to 160 °C 
(-58 °F to 320 °F)
-80 °C to 300 °C 
( -112 °F to 572 °F)
Accuracy (1 year) ± 0.05 °C (± 0.09 °F)
Display units °C, °F
Sensor type 100 Ω thin-film RTD 100 Ω wire-wound PRT
Probe temperature coefficient 0.00385 Ω/Ω/°C nominal
Sensor length ≤ 10 mm ≤ 30 mm
Sensor position (from sheath tip) 3 mm (0.1 in)
Minimum immersion depth 7 cm (2.8 in) 12 cm (4.8 in)
Probe sheath material Stainless steel
Response time 4.8 mm diameter probe (3/16 in): 14 seconds 
6.35 mm diameter probe (1/4 in): 21 seconds
Probe hysteresis ± 0.01 °C
Temperature resolution Selectable: 0.1, 0.01, 0.001 (default 0.01)
Sample rate Selectable: 0.5 seconds, 1 seconds, 2 seconds (default 1 seconds)
Operating temperature range readout -10 °C to 50 °C (14 °F to 122 °F)
Temperature resolution Selectable: 0.1, 0.01, 0.001 (default 0.01)
Sample rate Selectable: 0.5 seconds, 1 seconds, 2 seconds (default 1 seconds)
Operating temperature range readout -10 °C to 50 °C (14 °F to 122 °F)
Storage temperature -20 °C to 60 °C (-4 °F to 140 °F) 0 % to 95 % RH, non-condensing
Optional data logging1 Up to 10,000 time-stamped readings stored to internal memory
Logging intervals1 2 seconds, 5 seconds, 10 seconds, 30 seconds, or 60 seconds; 
2 minutes, 5 minutes, 10 minutes, 30 minutes, or 60 minutes
Damping Moving average of the most recent 2 to 10 readings 
(ON/OFF, 2, 5, 10)
Communications RS-232 stereo jack (access calibration parameters only)
AC power None
DC power 3-AAA Batteries, typical battery life of 300 hours without LCD backlight
EMC compliance EN61326:2006 Annex C; CISPR II Edition 5.0-2009; Class “B
Enclosure rating IP50
Electronics dimensions (H x W x D) 114 mm x 57 mm x 25 mm 
(4.5 in x 2.25 in x 1.0 in)
Weight 196 g (6.9 oz)
Calibration (included) NVLAP-accredited, NIST-traceable
Characterization CVD ITS-90