All Fluke Calibration Products

Fluke 1524-256 2-Channel Handheld Thermometer Kit 3

SKU
1524-P3-256
Rating:
0%
(0)
Reward Points
:
3172
£3,806.40 £3,172.00
Made to Order
Free UK Delivery*

Black Friday - Free Items With Orders Over £300

Black Friday Freebies
Spend £100 to £749.99
LED Head Torch (Worth: £15.99)

Spend Over £750
Free LED Head Torch & Extendable Flash Light (Worth: £35.98)

Prices Ex VAT
Advice & Support Call 01642 931329 or contact us
Price Match We won't be beaten, let us know
Fluke 1524-256 2-Channel Handheld Thermometer Kit 3

The Fluke 1524-256 2-Channel Handheld Thermometer Kit 3 contains:

  • 1x Fluke 1524-256 2-Channel Handheld Thermometer and Accessories
  • 1x Fluke 5627A 12” Precision Thermometer and RTD Temperature Probe
  • 1x Fluke 2373-LTC Lemo to Universal Thermocouple Adapter
  • 1x Carry Case

For further information regarding these products, please see the descriptions below.

Fluke 1524-256 2-Channel Handheld Thermometer Description

The Fluke 1524-256 2-Channel Handheld Thermometer can be used to log temperature readings as well as measure, graph and record PRTs, thermistors and thermocouples.

 It is suitable for the following applications:

  • Calibration
  • Loop-checking
  • Plant start-up
  • Troubleshooting
  • Maintenance
  • Repair

It is also suitable for use as a temperature reference and temperature logger in calibration baths, dry-block calibrators, thermowells, clean rooms, engines, heat exchangers, furnaces and freezers.

This instrument includes two channels and is able to conduct measurements simultaneously via each one. In addition to this, in order to facilitate its extensive measurement capabilities the Fluke 1524-256 2-Channel Handheld Thermometer includes three sensors with the following ranges:

  • PRT sensor: -200°C to 1000°C (±0.011°C)
  • Thermocouple sensor: -200°C to 2315°C (±0.24°C for J, K, L and M)
  • Thermistor sensor: -50°C to 150°C (±0.002°C)

Measurements are viewable via the 128 x 64-pixel, backlit, LCD display. The user is able to view data from both channels simultaneously, as well as view a trend graph that is scaled and plotted in real-time. In order to monitor processes over time and/or determine temperature stability quickly and without the use of statistics, the operator can utilise a function button optimised to alter the resolution of the graph.

The Fluke 1524-256 2-Channel Handheld Thermometer has the capacity to store up to 15 000 measurements, it also includes a real-time clock allowing readings to be saved with date and time stamps. As standard the Fluke 1524-256 2-Channel Handheld Thermometer has a sample rate of one reading per second, however, this can be reduced to one reading per hour or increased to one reading per 0.3 seconds (Fast Mode). The Fluke 1524-256 2-Channel Handheld Thermometer can also be set to collect samples at intervals between these two extremes.

Furthermore, using the RS-232 interface and supplied Fluke 9940 Toolkit Software the user can log and organise data collected by the Fluke 1524-256 2-Channel Handheld Thermometer. These accessories can also be used to send commands directly to the Fluke 1524-256 2-Channel Handheld Thermometer as well as create and upload probe configurations to the instrument.

The Fluke 1524-256 2-Channel Handheld Thermometer includes an INFO-CON memory chip to which probe configurations may be saved. This thermometer can accommodate RTDs/PRTs, thermistors and thermocouples; it will identify the probe attached and will subsequently recall the relevant calibration information from the INFO-CON memory chip. This ensures that the Fluke 1524-256 2-Channel Handheld Thermometer is correctly adjusted to perform correct temperature conversions for accurate measurements.

Further to this, probes can be locked to particular channels (using a password) in order to maintain system calibration traceability.

Adding to the reliability and accuracy of this instrument is its ability to maintain its precision in a variety of external temperature conditions; this is due to the inclusion of precision thermistors and a highly stable reference voltage source. Furthermore, this instrument has been tested in extremes of temperature and harsh vibration conditions to ensure that it maintains its accuracy and functionality in challenging environments.

Moreover, the Fluke 1524-256 2-Channel Handheld Thermometer utilises a current reversal technique which eliminates thermal EMFs, again adding to the precision of this instrument’s readings.

The Fluke 1524-256 2-Channel Handheld Thermometer is accurate, reliable and versatile. It has also been optimised to provide the user with extended periods of operation; to this end, it can be powered for up to twenty hours using three AA batteries. To extend this period of operation the Fluke 1524-256 2-Channel Handheld Thermometer includes power-saving settings and a DC adapter which may be used to extend this instrument’s period of functionality.

The Fluke 1524-256 2-Channel Handheld Thermometer is an adaptable, reliable and practical measurement tool and data logger, it is ideal for a variety of temperature calibration applications.

Fluke 1524-256 2-Channel Handheld Thermometer Key Features

  • Can be used to log temperature readings as well as measure, graph and record PRTs, thermistors and thermocouples
  • Ideal for calibration, loop-checking, plant start-up, troubleshooting, maintenance and repair applications
  • Suitable for serving as a temperature reference and temperature logger during calibration applications
  • Can conduct measurements via both channels simultaneously
  • PRT sensor: -200°C to 1000°C (±0.011°C)
  • Thermocouple sensor: -200°C to 2315°C (±0.24°C for J, K, L and M)
  • Thermistor sensor: -50°C to 150°C (±0.002°C)
  • 128 x 64-pixel, backlit, LCD display
  • View data from both channels simultaneously via the display
  • Trend graph is plotted and scaled in real-time
  • Trend graph is also viewable via the display
  • Function button for changing the resolution of the graph
  • Monitor processes over time
  • Determine temperature stability quickly and without the use of statistics
  • Save up to 15 000 measurements to the instrument’s memory
  • Includes a real-time clock for adding date and time stamps to saved measurements
  • Has a standard sample rate of one reading per second
  • Sample rate can be set at intervals anywhere between one reading an hour and one reading per 0.3 seconds (Fast Mode)
  • The included RS-232 interface and Fluke 9940 Toolkit Software can be used to log and organise data recorded by the thermometer
  • The supplied software and interface can also be used to send commands to the thermometer and create probe configurations which can be uploaded to the instrument
  • Probe configurations can be saved to the INFO-CON memory chip
  • Can accommodate PRTs/RTDs, thermistors and thermocouples
  • Will automatically identify which probe is connected and will subsequently recall the relevant calibration information from the INFO-CON memory chip
  • Probes can be locked to particular channels using a password thereby helping to maintain system calibration traceability
  • Includes precision thermistor
  • Includes a highly stable reference voltage source
  • Tested in extremes of temperature and harsh vibration conditions to ensure that the instrument maintains its accuracy and functionality in challenging environments
  • Utilises a current reversal technique to eliminate thermal EMFs
  • Power using three AA batteries for up to 20 hours
  • Power-saving settings
  • Use with the DC adapter to extend the thermometer’s period of operation
  • Can be used with Fluke’s LogWare II Software (NOT included)
  • An adaptable, reliable and practical measurement tool and data logger
  • Ideal for a variety of temperature calibration applications

What’s Included with the Fluke 1524-256 2-Channel Handheld Thermometer?

  • Fluke 1524-256 2-Channel Handheld Thermometer
  • NIST-traceable Certificate of Calibration
  • User Guide
  • CD-ROM Containing the Technical Manual
  • 12V DC Universal Power Supply
  • RS-232 Cable
  • Fluke 9940 I/O Toolkit Software

Fluke 5627A 12” Precision Thermometer and RTD Temperature Probe Description

The Fluke 5627A 12” Precision Thermometer and RTD Temperature Probe can be used with the Fluke 1524-256 2-Channel Handheld Thermometer to measure temperatures between -200˚C and 420˚C to an accuracy of up to ±0.025˚C.

This instrument is supplied with an NVLAP-accredited report of calibration (lab code 200706-0) and has been calibrated at the following temperatures: -196°C, -38°C, 0°C, 200°C and 420°C. It is also provided with ITS-90 coefficients and a calibration table in increments of 1˚C.

In addition to this, the Fluke 5627A 12” Precision Thermometer and RTD Temperature Probe conforms to the standard 385 curve which makes it suitable for use with DIN/IEC RTD meters.

As well as accuracy and reliability, the Fluke 5627A 12” Precision Thermometer and RTD Temperature Probe has been optimised for durability. Its mineral insulated sheath, with a minimum bend radius of 19mm, ensures that it is flexible and resilient, whilst its coil suspension element provides it with resistance against shocks and vibrations.

The Fluke 5627A 12” Precision Thermometer and RTD Temperature Probe is an accurate and reliable temperature probe optimised for longevity. It is ideal for extending the measurement capabilities of the Fluke 1524-256 2-Channel Handheld Thermometer.

Fluke 5627A 12” Precision Thermometer and RTD Temperature Probe Key Features

  • Can be used with the Fluke 1524-256 2-Channel Handheld Thermometer to measure temperature
  • Temperature range: -200˚C to 420˚C
  • Accuracy: up to ±0.025˚C
  • Supplied with an NVLAP-accredited calibration (lab code 200706-0)
  • Calibrated at the following temperatures: -196°C, -38°C, 0°C, 200°C and 420°C
  • Supplied with ITS-90 coefficients
  • Provided with a calibration table in increments of 1˚C
  • Conforms to the standard 385 curve
  • Suitable for use with DIN/IEC RTD meters
  • Mineral insulated sheath with a minimum bend radius of 19mm
  • Sheath ensures flexibility and longevity
  • Coil suspension element provides resistance against shocks and vibrations
  • Accurate and reliable temperature probe optimised for longevity
  • Ideal for extending the measurement capabilities of Fluke’s 1524-256 2-Channel Handheld Thermometer

Fluke 2373-LTC Lemo to Universal Thermocouple Adapter Description

The Fluke 2373-LTC Lemo to Universal Thermocouple Adapter can be used to facilitate a connection between the Fluke 1524-256 2-Channel Handheld Thermometer and any thermocouple with a mini thermocouple jack.

This instrument supports reference junction compensation and includes a precision thermistor.

The Fluke 2373-LTC Lemo to Universal Thermocouple Adapter is the ideal accessory for adding to the versatility of the Fluke 1524-256 2-Channel Handheld Thermometer.

Fluke 2373-LTC Lemo to Universal Thermocouple Adapter Key Features

  • Facilitates a connection between any thermocouple with a mini-thermocouple jack and the Fluke 1524-256 2-Channel Handheld Thermometer
  • Supports reference junction compensation
  • Includes a precision thermistor
  • Ideal accessory for adding to the versatility of the Fluke 1524-256 2-Channel Handheld Thermometer

What’s Included in the Fluke 1524-256 2-Channel Handheld Thermometer Kit 3?

  • 1x Fluke 1524-256 2-Channel Handheld Thermometer and Accessories
  • 1x Fluke 5627A 12” Precision Thermometer and RTD Temperature Probe
  • 1x Fluke 2373-LTC Lemo to Universal Thermocouple Adapter
  • 1x Carry Case

Fluke 1524-256 2-Channel Handheld Thermometer Kit 3 Technical Specifications

Please find the available technical specifications for the instruments included in the Fluke 1524-256 2-Channel Handheld Thermometer Kit 3. 

Fluke 1524-256 2-Channel Handheld Thermometer Technical Specifications 

Please note that the Fluke 1524-256 2-Channel Handheld Thermometer has a sister product, the Fluke 1523-256 1-Channel Handheld Thermometer, please find below the technical specifications for both of these models. 

Specification 1523 1524
Input channels 1 2
Resolution PRTs and thermistors: 0.001° thermocouples: 0.01°
Logging 25 readings with statistics 25 readings with statistics15,000 time and date stamped
Sample interval (normal) 1 second 1 second (simultaneous measurement)
Typical sample interval (fast mode) 0.3 seconds
Sensor types PRTs, RTDs, thermistors, and thermocouples
Thermocouple types C, E, J, K, L, M, N, T, U, B, R, S
Statistics Maximum, minimum, average, standard deviation
Trending Scale: ±10 °C (18 °F), ±1 °C (1.8 °F), ± 0.1°C (0.18 °F), ± 0.01°C (0.018 °F), 10 minutes of real-time data
Power requirements 3 AA alkaline batteries, 12 V dc universal power supply
Size (HxWxD 96 mm x 200 mm x 47 mm (3.75 in x 7.9 in x 1.86 in)
Weight 0.65 kg (1.4 lb)
Computer interface RS-232, 9940 I/O ToolKit software included
Safety EN61010-1:2001, CAN/CSA C22.2 No. 61010.1-04
Environmental conditions for best accuracy: 13 °C to 33 °C (55.4 °F to 91.4 °F)
Millivolt range and accuracy –10 mV to 75 mV, ± (0.005 % + 5 µV)
Internal reference junction compensation ± 0.2 °C (± 0.36 °F)
Resistance range and accuracy

0 Ω to 400 Ω ± (0.004 % + 0.002 Ω)

200 Ω to 50 kΩ ± (0.01 % + 0.5 Ω)

50 kΩ to 500 kΩ ± (0.03 %)

Temperature coefficient, voltage:

–10 °C to 13 °C , +33 °C to 60 °C

(14 °F to 55.4 °F, 91.4 °F to 140 °F)

± (0.001 %/°C + 1 mV/°C)

Temperature coefficient, resistance:

–10 °C to 13 °C ,+33 °C to 60 °C

(14 °F to 55.4 °F, 91.4 °F to 140 °F)

0.0008 %/°C + 0.0004 Ω (0 Ω to 400 Ω)

0.002 %/°C + 0.1 Ω (0 Ω to 50 kΩ)

0.06 %/°C + 0.1 Ω (50 kΩ to 500 kΩ)

Excitation current, resistance 1 mA (0 Ω to 400 Ω) 10 µA (0 Ω to 50 kΩ) 2 µA (50 kΩ to 500 kΩ)
*See technical manual for sample interval details by sensor type and number of inputs.

Fluke 5627A 12” Precision Thermometer and RTD Temperature Probe Technical Specifications 

Resistance Nominal 100 Ω
Temperature Coefficient 0.00385 Ω/Ω/ °C nominal
Temperature Range −200 °C to 420 °C
Drift Rate (k=2) ± 0.04 °C at 0 °C after 100 hours at 420 °C
Sheath Material 316 Stainless Steel
Leads PTFE-insulated, nickel-plated stranded copper, 22 AWG
Termination Specify. See Ordering Information.
Time Constant Four seconds maximum for 63.2 % response to step change in water moving at 3 fps.
Bending Radius Sheath may be ordered with a bend on a minimum radius of 19 mm (3/4 in) except for 50 mm (2 in) area of sheath near tip. (Fluke lab requires 20 cm [8 in] of unbent sheath to re-calibrate.)
Calibration

Includes manufacturer's NVLAP-accredited (lab code 200706-0) calibration and table with R vs. T values in 1 °C increments from -196 °C to 500 °C 

ITS-90 coefficients included.

Immersion At least 100 mm (4 in) recommended
Calibrated Accuracy† (k=2) ± 0.026 °C at -196 °C
± 0.046 °C at 0 °C
± 0.077 °C at 200 °C
± 0.124 °C at 420 °C
Size 305 mm x 6.35 mm (12 in x 1/4 in)
†Includes calibration uncertainty and 100 hr drift.

Fluke 1523-4 1-2-Channel Handheld Thermometer - Datasheet Datasheets Fluke 5627A 12” Precision Thermometer and RTD Temperature Probe - User Manual Manuals & Guides Fluke 1523-4 1-2-Channel Handheld Thermometer - Product Page Brochures & Catalogues Fluke 1523-4 1-2-Channel Handheld Thermometer - Brochure Brochures & Catalogues

Reviews

Additional Information
SKU 1524-P3-256
Manufacturer Part Code 3376674

Made to Order item: This item is made-to-order with a lead time once the order is placed. Once an order is placed it cannot be cancelled or returned unless the unit is found to be faulty.