Free Beanie Hat. Spend £250+ (ex VAT) View
All Fluke Calibration Products

Fluke 1524-256 2-Channel Handheld Thermometer Kit 2

SKU
1524-P2-256
Rating:
0%
(0)
Reward Points
:
4438
£5,325.60 £4,438.00
Made to Order
Free UK Delivery*
Advice & Support Call 01642 931329 or contact us
Price Match We won't be beaten, let us know
Fluke 1524-256 2-Channel Handheld Thermometer Kit 2

The Fluke 1524-256 2-Channel Handheld Thermometer Kit 2 contains:

  • 1x Fluke 1524-256 2-Channel Handheld Thermometer and Accessories
  • 1x Fluke 5628 Secondary Standard PRT Probe
  • 1x Fluke 2373-LTC Lemo to Universal Thermocouple Adapter
  • 1x Carry Case

For further information regarding these products, please see the descriptions below.

Fluke 1524-256 2-Channel Handheld Thermometer Description

The Fluke 1524-256 2-Channel Handheld Thermometer can be used to log temperature measurements, as well as measure, graph and record PRTs, thermistors and thermocouples.

It includes three sensors with the following ranges and accuracies:

  • PRT sensor: -200°C to 1000°C (±0.011°C)
  • Thermocouple sensor: -200°C to 2315°C (±0.24°C for J, K, L and M)
  • Thermistor sensor: -50°C to 150°C (±0.002°C)

The Fluke 1524-256 2-Channel Handheld Thermometer is able to conduct measurements simultaneously via its two channels. These measurements may be viewed simultaneously via the 128 x 64-pixel, backlit, LCD display. On the display, the user can also view trend graphs which are plotted and scaled in real-time. A dedicated function button allows the user to alter the resolution to the suit the application facilitating his/her ability to monitor processes over time and/or determine temperature stability quickly and without the use of statistics.

As standard, this instrument has a sample rate of one reading per second. However, it may be set to record temperatures at intervals as sporadic as one per hour or as frequently as one per 0.3 seconds (Fast Mode), as well as at intervals anywhere between these two limits. In order to accommodate these data logging capabilities, as well as the additional measurements that are taken using the second channel, the Fluke 1524-256 2-Channel Handheld Thermometer includes an extensive memory capable of saving up to 15 000 readings with date and time stamps. This thermometer includes a real-time clock in order to generate accurate date and time stamps.

Data can be uploaded to a PC using the included RS-232 interface and the supplied Fluke 9940 Toolkit Software. These accessories can be used to log and organise data collected by the Fluke 1524-256 2-Channel Handheld Thermometer.  These components can also be used to create and upload probe configurations to the Fluke 1524-256 2-Channel Handheld Thermometer as well as send commands directly to the instrument.

In addition to this, the Fluke 1524-256 2-Channel Handheld Thermometer can be used with Fluke’s LogWare II Software for applications involving greater volumes of data-logging and –monitoring.

Information regarding probe configurations is saved to the Fluke 1524-256 2-Channel Handheld Thermometer’s INFO-CON memory chip. Once a probe is connected, the Fluke 1524-256 2-Channel Handheld Thermometer will recall the relevant calibration information from the INFO-CON memory chip, thereby ensuring that the Fluke 1524-256 2-Channel Handheld Thermometer is correctly adjusted to perform correct temperature conversions for accurate measurements.

This instrument is able to accommodate PRTs/RTDs, thermistors and thermocouples and particular probes may be locked to certain channels using a password, allowing the user to maintain system calibration traceability.

Also adding to the accuracy and reliability of this instrument is its utilisation of a current reversal technique which eliminates thermal EMFs. Further to this, it includes precision resistors and a highly stable reference voltage source which work to maintain the Fluke 1524-256 2-Channel Handheld Thermometer’s accuracy in spite of external temperatures. Indeed this instrument has been tested in extreme temperatures and harsh vibration conditions in order to ensure its accuracy and functionality are maintained in challenging environments.

This instrument is powered using three AA batteries and is able to remain operational for up to twenty hours using this power source. This period of functionality can be extended using the supplied DC adapter and the Fluke 1524-256 2-Channel Handheld Thermometer’s integrated power-saving settings.

The Fluke 1524-256 2-Channel Handheld Thermometer is an ergonomically designed, practical, versatile and reliable temperature logger and measurement instrument. It can be used as a reference temperature and logger in calibration baths, dry-block calibrators, thermowells, clean rooms, engines, heat exchangers, furnaces and freezers. It is particularly well suited to calibration, loop-checking, plant start-up, troubleshooting, maintenance and repair applications.

Fluke 1524-256 2-Channel Handheld Thermometer Key Features

  • Can be used to log temperature measurements, as well as measure, graph and record PRTs, thermistors and thermocouples
  • PRT sensor: -200°C to 1000°C (±0.011°C)
  • Thermocouple sensor: -200°C to 2315°C (±0.24°C for J, K, L and M)
  • Thermistor sensor: -50°C to 150°C (±0.002°C)
  • Two channels
  • Can conduct measurements simultaneously via the two channels
  • Readings for both channels can be viewed via the display
  • 128 x 64-pixel, backlit, LCD display
  • View trend graphs that are plotted and scaled in real-time via the display
  • Function button for altering the resolution of the graph
  • Monitor processes over time
  • Determine temperature stability quickly and without the use of statistics
  • Standard sample rate: 1 reading per second
  • Set the sample rate at intervals anywhere between one reading an hour and one reading per 0.3 seconds
  • Fast Mode sample rate: 1 reading per 0.3 seconds
  • Includes an extensive memory capable of saving up to 15 000 measurements with date and time stamps
  • Includes a real-time clock
  • Data can be uploaded to a PC using the RS-232 interface and supplied Fluke 9940 Toolkit Software
  • Log and organise data captured by the thermometer using the RS-232 interface and supplied Fluke 9940 Toolkit Software
  • Interface and software can also be used to create probe configurations to be uploaded to the thermometer
  • Interface and software can be used to send commands to the thermometer
  • Can be used in conjunction with Fluke’s LogWare II Software (NOT included)
  • Information regarding probe configurations can be sent to the INFO-CON memory chip
  • Once a probe is connected the thermometer will recall the relevant calibration information from the INFO-CON memory chip
  • Can accommodate PRTs/RTDs, thermistors and thermocouples
  • Particular probes can be saved to specific channels using a password in order to maintain system calibration traceability
  • Utilises a current reversal technique which eliminates thermal EMFs
  • Includes precision resistors
  • Includes a highly stable reference voltage source
  • Tested in extremes of temperature and harsh vibration conditions in order to ensure the instrument maintains its accuracy and functionality in a variety of environments
  • Operate for up to 20 hours using three AA batteries
  • The supplied DC adapter can be used to extend this period of operation
  • Power-saving settings
  • Ergonomically designed
  • Can be used as a temperature reference and logger
  • Ideal for calibration, loop-checking, plant start-up, troubleshooting, maintenance and repair applications

What’s Included with the Fluke 1524-256 2-Channel Handheld Thermometer?

  • Fluke 1524-256 2-Channel Handheld Thermometer
  • NIST-traceable Certificate of Calibration
  • User Guide
  • CD-ROM Containing the Technical Manual
  • 12V DC Universal Power Supply
  • RS-232 Cable
  • Fluke 9940 I/O Toolkit Software

Fluke 5628 Secondary Standard PRT Probe Description

The Fluke 5628 Secondary Standard PRT Probe can be used with the above Fluke 1524-256 2-Channel Handheld Thermometer to measure temperatures between -200°C and 661°C.

This instrument is nominally 25.5Ω and has an accuracy of between ±0.006°C and ±0.022°C, depending on the temperature. It is supplied with an accredited calibration with ITS-90 constants and a resistance-versus-temperature table.

Also working to preserve the accuracy and reliability of the Fluke 5628 Secondary Standard PRT Probe is the inclusion of internal protection which reduces the risk of contamination without affecting performance.

The Fluke 5628 Secondary Standard PRT Probe’s extensive measuremetn range and robust design make it suitable for a number of calibration applications, for instance:

  • Serving as a working and/or check standard for calibration work up to aluminium point
  • Suitable for when the operator is using temperature points above 420°C (normal PRT temperatures)

The Fluke 5628 Secondary Standard PRT Probe is ideal for extending the capabilities of the Fluke 1524-256 2-Channel Handheld Thermometer.

Fluke 5628 Secondary Standard PRT Probe Key Features

  • Can be used with the Fluke 1524-256 2-Channel Handheld Thermometer to measure temperatures
  • Temperature range: -200°C to 661°C
  • Nominally 25.5Ω
  • Has an accuracy of between ±0.006°C and ±0.022°C (depending on the temperature)
  • Supplied with an accredited calibration with ITS-90 constants and a resistance-versus-temperature table
  • Includes internal protection which prevents contamination without affecting performance
  • Suitable for calibration applications
  • Can serve as a working and/or check standard for calibration work up to aluminium point
  • Suitable for when the operator is using temperature points above 420°C (normal PRT temperatures)
  • Ideal for extending the capabilities of the Fluke 1524-256 2-Channel Handheld Thermometer

Fluke 2373-LTC Lemo to Universal Thermocouple Adapter Description

The Fluke 2373-LTC Lemo to Universal Thermocouple Adapter allows the user to connect thermocouples with mini thermocouple jacks to the Fluke 1524-256 2-Channel Handheld Thermometer.

It includes a precision thermistor and supports reference junction compensation.

The Fluke 2373-LTC Lemo to Universal Thermocouple Adapter is ideal for expanding the Fluke 1524-256 2-Channel Handheld Thermometer’s scope-for-use.

Fluke 2373-LTC Lemo to Universal Thermocouple Adapter Key Features

  • Allows the user to connect thermocouples with mini-thermocouple jacks to the Fluke 1524-256 2-Channel Handheld Thermometer.
  • Includes a precision thermistor
  • Supports reference junction compensation
  • Ideal for expanding the Fluke 1524-256 2-Channel Handheld Thermometer’s scope-for-use

What’s Included in the Fluke 1524-256 2-Channel Handheld Thermometer Kit 2?

  • 1x Fluke 1524-256 2-Channel Handheld Thermometer and Accessories
  • 1x Fluke 5628 Secondary Standard PRT Probe
  • 1x Fluke 2373-LTC Lemo to Universal Thermocouple Adapter
  • 1x Carry Case

Fluke 1524-256 2-Channel Handheld Thermometer Kit 2 Technical Specifications 

Please find the technical specifications available for the products included in this kit.

Fluke 1524-256 2-Channel Handheld Thermometer Technical Specifications 

Please note that the Fluke 1524-256 2-Channel Handheld Thermometer has a sister product, the Fluke 1523-256 1-Channel Handheld Thermometer, please find below the technical specifications for both of these models. 

Specification 1523 1524
Input channels 1 2
Resolution PRTs and thermistors: 0.001° thermocouples: 0.01°
Logging 25 readings with statistics 25 readings with statistics15,000 time and date stamped
Sample interval (normal) 1 second 1 second (simultaneous measurement)
Typical sample interval (fast mode) 0.3 seconds
Sensor types PRTs, RTDs, thermistors, and thermocouples
Thermocouple types C, E, J, K, L, M, N, T, U, B, R, S
Statistics Maximum, minimum, average, standard deviation
Trending Scale: ±10 °C (18 °F), ±1 °C (1.8 °F), ± 0.1°C (0.18 °F), ± 0.01°C (0.018 °F), 10 minutes of real-time data
Power requirements 3 AA alkaline batteries, 12 V dc universal power supply
Size (HxWxD 96 mm x 200 mm x 47 mm (3.75 in x 7.9 in x 1.86 in)
Weight 0.65 kg (1.4 lb)
Computer interface RS-232, 9940 I/O ToolKit software included
Safety EN61010-1:2001, CAN/CSA C22.2 No. 61010.1-04
Environmental conditions for best accuracy: 13 °C to 33 °C (55.4 °F to 91.4 °F)
Millivolt range and accuracy –10 mV to 75 mV, ± (0.005 % + 5 µV)
Internal reference junction compensation ± 0.2 °C (± 0.36 °F)
Resistance range and accuracy

0 Ω to 400 Ω ± (0.004 % + 0.002 Ω)

200 Ω to 50 kΩ ± (0.01 % + 0.5 Ω)

50 kΩ to 500 kΩ ± (0.03 %)

Temperature coefficient, voltage:

–10 °C to 13 °C , +33 °C to 60 °C

(14 °F to 55.4 °F, 91.4 °F to 140 °F)

± (0.001 %/°C + 1 mV/°C)

Temperature coefficient, resistance:

–10 °C to 13 °C ,+33 °C to 60 °C

(14 °F to 55.4 °F, 91.4 °F to 140 °F)

0.0008 %/°C + 0.0004 Ω (0 Ω to 400 Ω)

0.002 %/°C + 0.1 Ω (0 Ω to 50 kΩ)

0.06 %/°C + 0.1 Ω (50 kΩ to 500 kΩ)

Excitation current, resistance 1 mA (0 Ω to 400 Ω) 10 µA (0 Ω to 50 kΩ) 2 µA (50 kΩ to 500 kΩ)
*See technical manual for sample interval details by sensor type and number of inputs.

Fluke 5628 Secondary Standard PRT Probe Technical Specifications

Temperature Range –200 °C to 661 °C 
Handle Temp. 0 °C to 80 °C 
RTPW  25.5 Ω (± 0.5 Ω) 
Resistance Ratio W(Ga) W(302.9146K) ≥ 1.11807
α ≥ 0.003925
Calibrated Accuracy (k=2)  ± 0.006 °C at –200 °C
± 0.006 °C at 0 °C
± 0.015 °C at 420 °C
± 0.022 °C at 661 °C 
Stability  ± 0.002 °C 
Long-Term Drift (k=2)  < 0.004 °C/100 hours at 661 °C 
Immersion At least 12.7 cm (5 in) recommended 
Sheath Inconel™ 600
Lead Wires  4-wire Super-Flex PVC, 22 AGW 
Termination  Gold-plated spade lugs, or specify
Size  6.35 mm dia. x 305 mm,  381 mm,  or 508 mm (0.25 x 12, 15, or 20 in) standard, custom lengths available 
Calibration  Accredited calibrations from Fluke Calibration
Includes calibration and 100 hr drift
Fluke 1523-4 1-2-Channel Handheld Thermometer - Datasheet Datasheets Fluke 5626 and 5628 Standard PRTs - User Manual Manuals & Guides Fluke 1523-4 1-2-Channel Handheld Thermometer - Product Page Brochures & Catalogues Fluke 1523-4 1-2-Channel Handheld Thermometer - Brochure Brochures & Catalogues

Reviews

Additional Information
SKU 1524-P2-256
Manufacturer Part Code 3376656

Made to Order item: This item is made-to-order with a lead time once the order is placed. Once an order is placed it cannot be cancelled or returned unless the unit is found to be faulty.